Loading...

Electrical Wires & Cables

Electrical wires and cables are conductive materials that are used to transmit electrical power and signals from one location to another. They are an essential component of any electrical system, ranging from small electronic devices to large industrial installations.

Electrical wires are typically made of a conductive material, such as copper or aluminum, that is coated in an insulating material to prevent electrical leakage or short-circuits. They are available in various gauges and thicknesses to handle different levels of electrical current and resistance.

Cables, on the other hand, are bundles of two or more electrical wires that are wrapped in an outer jacket for protection and insulation. They are designed for specific purposes, such as transmitting high-speed data, audio, or video signals, and can be shielded or unshielded to reduce electromagnetic interference.

Both electrical wires and cables are critical components of modern electrical systems and are used in a wide range of applications, including residential and commercial buildings, automotive and aerospace industries, telecommunications, and more.

Electrical Wires & Cables

Available Parts 2,400+

Part# Info Specs
Part RoHS Manufacturer Description Additional Features Application Approvals (V) Cable Types Conductor Finish Conductor Material Connector Side-1 Connector Side-2 Connector Accessory Type Construction Cross Section Area DIN Conformity Design Diameter Finish Thickness IEC Conformity Insulator Material Jacket Material Length MIL Conformity Material Mounting Option-1 Mounting Option-2 Mounting Style No. of Conductors Maximum Operating Temperature Minimum Operating Temperature Rated Current Rated Voltage Rated DC Voltage Resistance Shielding Stranding Terminal Type Wire Gauge (AWG) Maximum Wire Size Minimum Wire Size Wire & Cable Name
2321761 by Phoenix Contact

2321761

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: FUJITSU CONN.; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

ASSEMBLY HAVE 4 CABLES

CUL; EAC; UL

TIN

COPPER

FUJITSU CONN.

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.1 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

6 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2321774 by Phoenix Contact

2321774

Phoenix Contact

Phoenix Contact 2321774 is a stranded wire with semi-rigid PVC jacket, rated for 60V and -40 to 70°C. Featuring tin finish copper conductor, it has 14 conductors at 0.14mm2 cross-section area. Ideal for flexible cord and fixture wire applications with FUJITSU CONN. to IDC/FLK SOCKET connectors.

ASSEMBLY HAVE 4 CABLES

CUL; EAC; UL

TIN

COPPER

FUJITSU CONN.

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.1 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

8 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2321787 by Phoenix Contact

2321787

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: FUJITSU CONN.; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

ASSEMBLY HAVE 4 CABLES

CUL; EAC; UL

TIN

COPPER

FUJITSU CONN.

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.1 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

10 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2736961 by Phoenix Contact

2736961

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 CONN.; Connector Side-2: 2 M8 MALE CONN.; Shielding: NO; Wire & Cable Name: COMMUNICATION CABLE; Minimum Operating Temperature: -25 Cel;

M12 CONN.

2 M8 MALE CONN.

CABLE ASSEMBLY

NO

NO

NO

5

60 Cel

-25 Cel

NO

COMMUNICATION CABLE

2288914 by Phoenix Contact

2288914

Phoenix Contact

Phoenix Contact 2288914 is a PVC jacketed communication cable with 14 copper conductors, rated for 60V and 1A. Featuring IDC/FLK SOCKET connectors on both ends, it has a cross-section area of 0.14mm2 and operates b/w -40 to 70°C. Ideal for various electrical applications requiring reliable data transmission.

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

.14 mm2

NO

6.4 mm

NO

PVC

1 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

COMMUNICATION CABLE

2288927 by Phoenix Contact

2288927

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1.5 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2288930 by Phoenix Contact

2288930

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

2 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2288943 by Phoenix Contact

2288943

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

2.5 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2288956 by Phoenix Contact

2288956

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

3 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2288969 by Phoenix Contact

2288969

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

3.5 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2288972 by Phoenix Contact

2288972

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

4 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2288985 by Phoenix Contact

2288985

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

.5 mm

NO

40

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2288998 by Phoenix Contact

2288998

Phoenix Contact

Phoenix Contact 2288998 is a stranded wire with semi-rigid PVC jacket, rated for 60V. Featuring tin finish copper conductor, it has a cross-section area of 0.14 mm2 and resistance of 0.145 ohm. Ideal for flexible cord and fixture wire applications with IDC/FLK socket connectors on both ends.

CUL; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1 mm

NO

40

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289007 by Phoenix Contact

2289007

Phoenix Contact

Phoenix Contact 2289007 is a stranded wire with semi-rigid PVC jacket, rated for 60V. Featuring tin finish copper conductor, it has approvals from CUL, EAC, and UL. Ideal for applications requiring flexible cord and fixture wire with IDC/FLK socket connectors.

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1.5 mm

NO

40

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289010 by Phoenix Contact

2289010

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

2 mm

NO

40

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289023 by Phoenix Contact

2289023

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

2.5 mm

NO

40

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289036 by Phoenix Contact

2289036

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

3 mm

NO

40

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289049 by Phoenix Contact

2289049

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

3.5 mm

NO

40

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289052 by Phoenix Contact

2289052

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

4 mm

NO

40

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289065 by Phoenix Contact

2289065

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

.5 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289078 by Phoenix Contact

2289078

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289117 by Phoenix Contact

2289117

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

3 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289120 by Phoenix Contact

2289120

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

3.5 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289133 by Phoenix Contact

2289133

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

4 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289573 by Phoenix Contact

2289573

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

4.5 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289586 by Phoenix Contact

2289586

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

5 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289599 by Phoenix Contact

2289599

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

5.5 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289609 by Phoenix Contact

2289609

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

6 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289625 by Phoenix Contact

2289625

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

7 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289638 by Phoenix Contact

2289638

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

7.5 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289641 by Phoenix Contact

2289641

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

8 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289654 by Phoenix Contact

2289654

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

8.5 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289667 by Phoenix Contact

2289667

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

9 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2289683 by Phoenix Contact

2289683

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

10 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2290834 by Phoenix Contact

2290834

Phoenix Contact

Phoenix Contact 2290834 is a stranded wire with semi-rigid PVC jacket, rated for 60V. Featuring tin finish copper conductor, it has approvals from CUL, EAC, and UL. Ideal for applications requiring flexible cord and fixture wire with IDC/FLK socket connectors.

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

5 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2290847 by Phoenix Contact

2290847

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

4.5 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2290863 by Phoenix Contact

2290863

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

6 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2294623 by Phoenix Contact

2294623

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1 mm

NO

40

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2294636 by Phoenix Contact

2294636

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1.5 mm

NO

40

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2294649 by Phoenix Contact

2294649

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

2 mm

NO

40

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2294652 by Phoenix Contact

2294652

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

3 mm

NO

40

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2295693 by Phoenix Contact

2295693

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

5.8 mm

NO

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2295729 by Phoenix Contact

2295729

Phoenix Contact

Phoenix Contact 2295729 is a stranded wire with semi-rigid PVC jacket, rated for 60V. With 26 AWG and copper conductor, it has approvals from CUL, EAC, and UL. Ideal for applications requiring flexible cord and fixture wire with IDC/FLK socket connectors.

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

.3 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2296223 by Phoenix Contact

2296223

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

12 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2296391 by Phoenix Contact

2296391

Phoenix Contact

Phoenix Contact 2296391 is a stranded wire with semi-rigid PVC jacket, rated for 60V. Featuring tin finish copper conductor, it has approvals from CUL, EAC, and UL. Ideal for applications requiring flexible cord and fixture wire with IDC/FLK socket connectors.

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

7.6 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

.5 mm

NO

20

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2296401 by Phoenix Contact

2296401

Phoenix Contact

Phoenix Contact 2296401 is a stranded wire with semi-rigid PVC jacket, rated for 60V. Featuring tin finish copper conductor, it has a cross section area of 0.14 mm2 and resistance of 0.145 ohm. Ideal for applications requiring flexible cord and fixture wire with IDC/FLK socket connectors.

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

7.6 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1 mm

NO

20

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2296472 by Phoenix Contact

2296472

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

7.6 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1.5 mm

NO

20

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2296485 by Phoenix Contact

2296485

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

7.6 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

2 mm

NO

20

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE