Loading...
Part# Info Electrical Specifications Physical Dimensions Fuse Characteristics Operational Environment Design and Compliance Mounting and Packing
Part RoHS Manufacturer Description Rated Current Rated Breaking Capacity Rated AC Voltage Rated DC Voltage Body Height Body Length/Diameter Body Width Dimensions Actuator Type Blow Characteristic Trip Time/Delay Circuit Function No. of Poles Circuit Protection Type Additional Features Minimum Operating Temperature Maximum Operating Temperature Environmental Characteristics Reference Standard Manufacturer Series JESD-609 Code Terminal Shape Terminal Finish Mounting Feature Packing Method
GA2-B3-11-663-12-MC by Carling Technologies

GA2-B3-11-663-12-MC

Carling Technologies

Carling Technologies GA2-B3-11-663-12-MC is a 63A magnetic circuit breaker with 3000A breaking capacity. It features corrosion/moisture resistance, snap-on terminals, and DIN-rail mounting. Ideal for applications requiring series trip circuit protection in environments with temperatures ranging from -40°C to 85°C.

63 A

3 kA

80 V

2.62 in (66.55 mm)

4.188 in (106.38 mm)

1.376 in (34.95 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA, UL

Snap On

DIN Rail Mount

EA1-B4-74-810-FDE-AB by Carling Technologies

EA1-B4-74-810-FDE-AB

Carling Technologies

Carling Technologies EA1-B4-74-810-FDE-AB is a 100A magnetic circuit breaker with 5000A breaking capacity. It features corrosion/moisture resistance, screw terminals, and a handle actuator. Ideal for panel mounting in applications requiring series trip circuit protection at temperatures ranging from -40°C to 85°C.

100 A

5 kA

65 V

2.61 in (66.3 mm)

5.78 in (146.81 mm)

1.026 in (26.06 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

EA1-B4-74-810-GDE-AB by Carling Technologies

EA1-B4-74-810-GDE-AB

Carling Technologies

Carling Technologies EA1-B4-74-810-GDE-AB is a 100A magnetic circuit breaker with 5000A breaking capacity. It has corrosion/moisture resistance, operates b/w -40°C to 85°C, and is CSA/UL certified. Ideal for panel mounting in applications requiring reliable series trip protection.

100 A

5 kA

65 V

2.61 in (66.3 mm)

5.78 in (146.81 mm)

1.026 in (26.06 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

CLB-103-27E3A-W-A by Carling Technologies

CLB-103-27E3A-W-A

Carling Technologies

Carling Technologies CLB-103-27E3A-W-A is a 10A thermal circuit breaker with 250V AC and 32V DC ratings. Featuring fire-resistant properties, it has quick connect terminals and push-to-reset actuator for panel mounting applications.

10 A

300 A

250 V

32 V

1.693 in (43 mm)

1.378 in (35 mm)

0.571 in (14.5 mm)

Push To Reset

Series Trip

1

Thermal Circuit Breaker

Rated breaking capacity at 32 VDC: 2500 A

-10 °C (14 °F)

60 °C (140 °F)

Fire Resistant

CE; TUV; UL

Quick Connect

Panel Mount

CLB-103-27E3N-B-F by Carling Technologies

CLB-103-27E3N-B-F

Carling Technologies

Carling Technologies' CLB-103-27E3N-B-F is a 10A thermal circuit breaker with 250V AC and 32V DC ratings. Its fire-resistant design, push-to-reset actuator, and CE/TUV/UL certifications make it ideal for panel-mounted series trip applications in environments ranging from -10°C to 60°C.

10 A

300 A

250 V

32 V

1.693 in (43 mm)

1.378 in (35 mm)

0.571 in (14.5 mm)

Push To Reset

Series Trip

1

Thermal Circuit Breaker

Rated breaking capacity at 32 VDC: 2500 A

-10 °C (14 °F)

60 °C (140 °F)

Fire Resistant

CE; TUV; UL

Screw

Panel Mount

CLB-103-27E3N-W-F by Carling Technologies

CLB-103-27E3N-W-F

Carling Technologies

Carling Technologies' CLB-103-27E3N-W-F is a 10A thermal circuit breaker with 250V AC and 32V DC ratings. Featuring fire-resistant properties, it has a push-to-reset actuator and panel mount for series trip applications. Compliant with CE, TUV, and UL standards, it operates b/w -10°C to 60°C temperatures efficiently.

10 A

300 A

250 V

32 V

1.693 in (43 mm)

1.378 in (35 mm)

0.571 in (14.5 mm)

Push To Reset

Series Trip

1

Thermal Circuit Breaker

Rated breaking capacity at 32 VDC: 2500 A

-10 °C (14 °F)

60 °C (140 °F)

Fire Resistant

CE; TUV; UL

Screw

Panel Mount

CLB-103-27E6A-B-A by Carling Technologies

CLB-103-27E6A-B-A

Carling Technologies

Carling Technologies CLB-103-27E6A-B-A is a 10A thermal circuit breaker with 250V AC and 32V DC ratings. Featuring fire-resistant properties, it has quick connect terminals and push-to-reset actuator for panel mounting applications.

10 A

300 A

250 V

32 V

1.693 in (43 mm)

1.378 in (35 mm)

0.571 in (14.5 mm)

Push To Reset

Series Trip

1

Thermal Circuit Breaker

Rated breaking capacity at 32 VDC: 2500 A

-10 °C (14 °F)

60 °C (140 °F)

Fire Resistant

CE; TUV; UL

Quick Connect

Panel Mount

CLB-103-27E6N-W-A by Carling Technologies

CLB-103-27E6N-W-A

Carling Technologies

Carling Technologies' CLB-103-27E6N-W-A is a 10A thermal circuit breaker with 250V AC and 32V DC ratings. Featuring fire-resistant properties, it has quick connect terminals and push-to-reset actuator for panel mounting applications. This series trip breaker operates b/w -10°C to 60°C, meeting CE, TUV, and UL standards.

10 A

300 A

250 V

32 V

1.693 in (43 mm)

1.378 in (35 mm)

0.571 in (14.5 mm)

Push To Reset

Series Trip

1

Thermal Circuit Breaker

Rated breaking capacity at 32 VDC: 2500 A

-10 °C (14 °F)

60 °C (140 °F)

Fire Resistant

CE; TUV; UL

Quick Connect

Panel Mount

CLB-103-27E7N-W-A by Carling Technologies

CLB-103-27E7N-W-A

Carling Technologies

Carling Technologies' CLB-103-27E7N-W-A is a 10A thermal circuit breaker with 250V AC and 32V DC ratings. Featuring fire-resistant properties, it has quick connect terminals and push-to-reset actuator for panel mounting applications. With CE, TUV, and UL certifications, it ensures series trip circuit protection in environments ranging from -10°C to 60°C.

10 A

300 A

250 V

32 V

1.693 in (43 mm)

1.378 in (35 mm)

0.571 in (14.5 mm)

Push To Reset

Series Trip

1

Thermal Circuit Breaker

Rated breaking capacity at 32 VDC: 2500 A

-10 °C (14 °F)

60 °C (140 °F)

Fire Resistant

CE; TUV; UL

Quick Connect

Panel Mount

BA1-B0-14-450-225-C by Carling Technologies

BA1-B0-14-450-225-C

Carling Technologies

Carling Technologies BA1-B0-14-450-225-C is a 5A magnetic circuit breaker with 7500A breaking capacity. It has a screw terminal shape, corrosion/moisture resistance, and operates b/w -40°C to 85°C. Ideal for panel mounting in applications requiring reliable circuit protection.

5 A

7.5 kA

80 V

1.73 in (43.94 mm)

2 in (50.8 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

BA3-B0-46-610-531-D by Carling Technologies

BA3-B0-46-610-531-D

Carling Technologies

Carling Technologies BA3-B0-46-610-531-D is a 10A magnetic circuit breaker with 277V AC voltage rating. It features corrosion/moisture resistance, toggle handle actuator, and screw terminals. Ideal for panel mounting in applications requiring series trip circuit protection up to 1500A breaking capacity.

10 A

1.5 kA

277 V

1.73 in (43.94 mm)

2 in (50.8 mm)

2.265 in (57.53 mm)

Toggle Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Screw

Panel Mount

BB2-B0-26-625-522-D by Carling Technologies

BB2-B0-26-625-522-D

Carling Technologies

Carling Technologies BB2-B0-26-625-522-D is a 25A magnetic circuit breaker with 250V AC voltage rating. It features corrosion/moisture resistance, screw terminals, and panel mount for series trip applications. Compliant with CSA, UL, VDE standards, it operates b/w -40°C to 85°C temperature range.

25 A

3 kA

250 V

1.73 in (43.94 mm)

2 in (50.8 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Screw

Panel Mount

BB2-B2-26-625-522-D by Carling Technologies

BB2-B2-26-625-522-D

Carling Technologies

Carling Technologies BB2-B2-26-625-522-D is a 25A magnetic circuit breaker with 250V AC voltage rating. It features corrosion/moisture resistance, screw terminals, and panel mount for series trip applications. Rated breaking capacity of 3000A, operating temperature range from -40°C to 85°C, and compliance with CSA, UL, VDE standards make it ideal for various electrical protection needs.

25 A

3 kA

250 V

1.73 in (43.94 mm)

2 in (50.8 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Screw

Panel Mount

BB3-B0-26-620-121-D by Carling Technologies

BB3-B0-26-620-121-D

Carling Technologies

Carling Technologies BB3-B0-26-620-121-D is a 20A magnetic circuit breaker with 277V AC voltage rating. Featuring quick connect terminals, toggle handle actuator, and corrosion-resistant body, it's ideal for panel mounting in applications requiring series trip circuit protection.

20 A

1.5 kA

277 V

1.73 in (43.94 mm)

2 in (50.8 mm)

2.265 in (57.53 mm)

Toggle Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Quick Connect

Panel Mount

BB3-B0-46-618-211-D by Carling Technologies

BB3-B0-46-618-211-D

Carling Technologies

Carling Technologies BB3-B0-46-618-211-D is a 250V, 18A magnetic circuit breaker with corrosion resistance. Featuring screw terminals and a handle actuator, it has a rated breaking capacity of 3000A. Ideal for panel mounting in applications requiring series trip circuit protection at temperatures ranging from -40°C to 85°C.

18 A

3 kA

250 V

1.73 in (43.94 mm)

2.265 in (57.53 mm)

2 in (50.8 mm)

Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Screw

Panel Mount

C13-B9-46-610-543-R by Carling Technologies

C13-B9-46-610-543-R

Carling Technologies

Carling Technologies C13-B9-46-610-543-R is a 10A magnetic circuit breaker with 250V AC voltage rating. It features corrosion/moisture resistance and operates in temperatures from -40°C to 85°C. Ideal for panel mounting, it has a breaking capacity of 5000A and is suitable for series trip applications.

10 A

5 kA

250 V

1.85 in (47 mm)

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Rocker

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; TUV; UL

Screw

Panel Mount

C13-B9-46-610-546-R by Carling Technologies

C13-B9-46-610-546-R

Carling Technologies

Carling Technologies C13-B9-46-610-546-R is a 10A magnetic circuit breaker with 250V AC voltage rating. Featuring corrosion/moisture resistance, it has a breaking capacity of 5000A and operates b/w -40°C to 85°C. Ideal for panel mounting in applications requiring reliable series trip protection.

10 A

5 kA

250 V

1.85 in (47 mm)

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Rocker

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; TUV; UL

Screw

Panel Mount

CF2-B0-26-650-644-D by Carling Technologies

CF2-B0-26-650-644-D

Carling Technologies

Carling Technologies CF2-B0-26-650-644-D is a 50A magnetic circuit breaker with 250V AC voltage rating. Featuring a corrosion-resistant design, it has a rocker actuator and stud terminals. Ideal for panel mounting applications, it offers a rated breaking capacity of 5000A and operates in temperatures ranging from -40°C to 85°C.

50 A

5 kA

250 V

2.16 in (54.86 mm)

2.5 in (63.5 mm)

1.515 in (38.48 mm)

Rocker

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Stud

Panel Mount

CJ3-B2-26-625-524-C by Carling Technologies

CJ3-B2-26-625-524-C

Carling Technologies

MAGNETIC CIRCUIT BREAKER; Mounting Feature: PANEL MOUNT; Rated AC Voltage: 277 V; Rated Current: 25 A; Terminal Shape: SCREW; Rated Breaking Capacity: 5000 A;

25 A

5 kA

277 V

2.16 in (54.86 mm)

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Rocker

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

CJ3-B2-26-625-524-D by Carling Technologies

CJ3-B2-26-625-524-D

Carling Technologies

MAGNETIC CIRCUIT BREAKER; Mounting Feature: PANEL MOUNT; Rated AC Voltage: 250 V; Rated Current: 25 A; Terminal Shape: SCREW; No. of Poles: 3;

25 A

5 kA

250 V

2.16 in (54.86 mm)

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Rocker

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Screw

Panel Mount

CT1-B2-12-610-121-MG by Carling Technologies

CT1-B2-12-610-121-MG

Carling Technologies

Carling Technologies CT1-B2-12-610-121-MG is a 10A magnetic circuit breaker with 10000A rated breaking capacity. It features corrosion/moisture resistance, stud terminal shape, and panel mount for series trip applications. Operating temperature ranges from -40°C to 85°C, suitable for various industries per CSA and UL standards.

10 A

10 kA

80 V

1.85 in (47 mm)

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Stud

Panel Mount

EA1-B0-14-670-22B-BC by Carling Technologies

EA1-B0-14-670-22B-BC

Carling Technologies

Carling Technologies EA1-B0-14-670-22B-BC is a 70A magnetic circuit breaker with 5000A breaking capacity. It features corrosion/moisture resistance, stud terminals, and operates b/w -40 to 85°C. Ideal for panel mounting in applications requiring reliable series trip protection at 125V DC.

70 A

5 kA

125 V

2.61 in (66.3 mm)

5.78 in (146.81 mm)

1.026 in (26.06 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Stud

Panel Mount

PCB-B1-22-650-1AD-E12 by Carling Technologies

PCB-B1-22-650-1AD-E12

Carling Technologies

Carling Technologies PCB-B1-22-650-1AD-E12 is a 240V, 50A circuit breaker with moisture resistance. Featuring a rocker actuator and UL reference standard, it has a rated breaking capacity of 5000A. Ideal for equipment leakage protection in panel-mounted applications at temperatures ranging from -35°C to 66°C.

50 A

5 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

3.015 in (76.58 mm)

Rocker

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

Moisture Resistant

UL

Stud

Panel Mount

PCG-BA-24-616-1DA-E12 by Carling Technologies

PCG-BA-24-616-1DA-E12

Carling Technologies

Carling Technologies' PCG-BA-24-616-1DA-E12 is a 240V, 16A circuit breaker with a rated breaking capacity of 3000A. Featuring a panel mount and handle actuator, it is ideal for equipment leakage protection in various applications. Compliant with CSA and UL standards, it operates b/w -35°C to 66°C temperatures efficiently.

16 A

3 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

CSA; UL

Stud

Panel Mount

PCG-BA-24-625-1GA-E11 by Carling Technologies

PCG-BA-24-625-1GA-E11

Carling Technologies

Carling Technologies PCG-BA-24-625-1GA-E11 is a 25A circuit breaker with 240V AC voltage rating. Featuring moisture-resistant design, it has a breaking capacity of 5000A and operates in temperatures from -35°C to 66°C. Ideal for equipment protection, it has a toggle handle actuator and UL certification for reliability.

25 A

5 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Toggle Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

Moisture Resistant

UL

Stud

Panel Mount

PCG-BA-24-630-11A-E12 by Carling Technologies

PCG-BA-24-630-11A-E12

Carling Technologies

Carling Technologies PCG-BA-24-630-11A-E12 is a 30A circuit breaker with 240V AC voltage rating. It features moisture-resistant design, UL standard compliance, and toggle handle actuator. Ideal for equipment protection in applications requiring series trip circuit function.

30 A

5 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Toggle Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

Moisture Resistant

UL

Stud

Panel Mount

PCG-BA-24-630-1AA-E12 by Carling Technologies

PCG-BA-24-630-1AA-E12

Carling Technologies

Carling Technologies PCG-BA-24-630-1AA-E12 is a 30A circuit breaker with 240V AC voltage rating. Featuring a body size of 96.52mm x 57.53mm x 75.57mm, it has a breaking capacity of 3000A and operates b/w -35°C to +66°C. Ideal for equipment protection in various applications, it is CSA and UL certified for quality assurance.

30 A

3 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

CSA; UL

Stud

Panel Mount

PCG-BA-24-650-1GA-E11 by Carling Technologies

PCG-BA-24-650-1GA-E11

Carling Technologies

Carling Technologies' PCG-BA-24-650-1GA-E11 is a 240V, 50A circuit breaker with moisture resistance. Featuring a toggle handle actuator and panel mount, it has a rated breaking capacity of 5000A. Ideal for equipment protection in various applications requiring UL standard compliance.

50 A

5 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Toggle Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

Moisture Resistant

UL

Stud

Panel Mount

PCG-BA-24-650-1GB-E11 by Carling Technologies

PCG-BA-24-650-1GB-E11

Carling Technologies

Carling Technologies PCG-BA-24-650-1GB-E11 is a 240V, 50A circuit breaker with a rated breaking capacity of 3000A. Featuring a panel mount design and handle actuator, it is ideal for equipment leakage protection in various applications. Compliant with CSA and UL standards, it ensures reliable circuit protection in temperatures ranging from -35°C to 66°C.

50 A

3 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

CSA; UL

Stud

Panel Mount

CTB-B-B-15 by Carling Technologies

CTB-B-B-15

Carling Technologies

Carling Technologies' CTB-B-B-15 is a 15A thermal circuit breaker with 250V AC and 50V DC ratings. Featuring a quick connect terminal shape, rocker actuator type, and panel mounting feature, it ensures series trip circuit protection with a high breaking capacity of 1000A. Ideal for various applications requiring reliable overcurrent protection.

15 A

1 kA

250 V

50 V

1.535 in (38.99 mm)

0.76 in (19.31 mm)

0.76 in (19.31 mm)

Rocker

Series Trip

1

Thermal Circuit Breaker

CE; CUL; UL; VDE

Quick Connect

Panel Mount

CMB-053-27G3N-W-A/05 by Carling Technologies

CMB-053-27G3N-W-A/05

Carling Technologies

Carling Technologies CMB-053-27G3N-W-A/05 is a 5A thermal circuit breaker with 250V AC and 32V DC ratings. Featuring push-to-reset actuator, it has a breaking capacity of 1000A and operates b/w -10°C to 60°C. Ideal for panel mounting in various applications requiring series trip circuit protection.

5 A

1 kA

250 V

32 V

1.78 in (45.2 mm)

1.154 in (29.3 mm)

0.551 in (14 mm)

Push To Reset

Series Trip

1

Thermal Circuit Breaker

-10 °C (14 °F)

60 °C (140 °F)

CSA; CE; CUL; TUV; UL

Quick Connect

Panel Mount

CA3-B0-20-615-121-C by Carling Technologies

CA3-B0-20-615-121-C

Carling Technologies

Carling Technologies CA3-B0-20-615-121-C is a 250V, 15A magnetic circuit breaker with corrosion resistance. Featuring a stud terminal shape and panel mount, it has a rated breaking capacity of 3000A. Ideal for applications requiring series trip circuit protection in environments with temperatures ranging from -40°C to 85°C.

15 A

3 kA

250 V

1.85 in (47 mm)

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA, UL

Stud

Panel Mount

CB4-B0-24-615-1C1-D by Carling Technologies

CB4-B0-24-615-1C1-D

Carling Technologies

Carling Technologies CB4-B0-24-615-1C1-D is a 15A magnetic circuit breaker with 250V AC voltage rating. It features corrosion/moisture resistance, stud terminals, and a series trip circuit function. Ideal for panel mounting applications, it meets CSA, UL, and VDE standards while offering a rated breaking capacity of 3000A.

15 A

3 kA

250 V

1.85 in (47 mm)

2.5 in (63.5 mm)

3.015 in (76.58 mm)

Handle

Series Trip

4

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA, UL, VDE

Stud

Panel Mount

MF1-B-32-410-1-CE3-B-C by Carling Technologies

MF1-B-32-410-1-CE3-B-C

Carling Technologies

MAGNETIC CIRCUIT BREAKER; Mounting Feature: PANEL MOUNT; Rated AC Voltage: 125 V; Rated DC Voltage: 80 V; Rated Current: 1 A; Terminal Shape: QUICK CONNECT;

1 A

360 A

125 V

80 V

1.53 in (38.86 mm)

1.56 in (39.62 mm)

0.77 in (19.56 mm)

Rocker

Series Trip

1

Magnetic Circuit Breaker

Rated breaking capacity at 80 VDC: 600 A

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA, UL

Quick Connect

Panel Mount

CA1-B0-34-615-121-D by Carling Technologies

CA1-B0-34-615-121-D

Carling Technologies

CA1-B0-34-615-121-D by Carling Technologies is a 15A magnetic circuit breaker with a rated AC voltage of 250V. It features corrosion/moisture resistance and operates in temperatures ranging from -40 to 85°C. Ideal for panel mounting, this breaker has a rated breaking capacity of 5000A and is suitable for series trip applications.

15 A

5 kA

250 V

80 V

1.85 in (47 mm)

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Stud

Panel Mount

CA2-B0-34-615-121-D by Carling Technologies

CA2-B0-34-615-121-D

Carling Technologies

Carling Technologies CA2-B0-34-615-121-D is a 15A circuit breaker with 480V AC voltage rating. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10kA. Ideal for panel mounting applications in UL standard compliant setups.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

DA2-B0-34-450-121-C by Carling Technologies

DA2-B0-34-450-121-C

Carling Technologies

Carling Technologies DA2-B0-34-450-121-C is a 250V, 5A magnetic circuit breaker with moisture resistance. Featuring a toggle handle actuator and screw terminals, it has a rated breaking capacity of 1500A. Ideal for panel mounting in applications requiring series trip circuit protection under temperatures ranging from -40°C to 85°C.

5 A

1.5 kA

250 V

2.165 in (54.99 mm)

3.612 in (91.75 mm)

1.515 in (38.48 mm)

Toggle Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Moisture Resistant

CSA; UL

Screw

Panel Mount

DA3-B0-20-615-121-C by Carling Technologies

DA3-B0-20-615-121-C

Carling Technologies

Carling Technologies DA3-B0-20-615-121-C is a 15A magnetic circuit breaker with 277V AC voltage rating. Featuring moisture-resistant design, it has a breaking capacity of 5000A and operates in temperatures ranging from -40°C to 85°C. Ideal for panel mounting applications requiring series trip circuit protection.

15 A

5 kA

277 V

2.165 in (54.99 mm)

3.612 in (91.75 mm)

2.265 in (57.53 mm)

Toggle Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Moisture Resistant

CSA; UL

Screw

Panel Mount

FA3-P0-14-870-22B-BT by Carling Technologies

FA3-P0-14-870-22B-BT

Carling Technologies

Carling Technologies FA3-P0-14-870-22B-BT is a 700A magnetic circuit breaker with 50000A rated breaking capacity. It features corrosion/moisture resistance, screw terminals, and UL certification. Ideal for panel mounting in applications requiring series trip circuit protection at temperatures ranging from -40°C to 85°C.

700 A

50 kA

125 V

2.968 in (75.38 mm)

7.125 in (180.98 mm)

4.5 in (114.3 mm)

Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

UL

Screw

Panel Mount

EA1-B0-16-670-22B-BB by Carling Technologies

EA1-B0-16-670-22B-BB

Carling Technologies

Carling Technologies EA1-B0-16-670-22B-BB is a 70A magnetic circuit breaker with 5000A rated breaking capacity. It features corrosion/moisture resistance and operates b/w -40°C to 85°C. Ideal for panel mounting in applications requiring reliable series trip circuit protection.

70 A

5 kA

125 V

2.61 in (66.3 mm)

5.78 in (146.81 mm)

1.026 in (26.06 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Stud

Panel Mount

EA1-B0-16-670-22B-BF by Carling Technologies

EA1-B0-16-670-22B-BF

Carling Technologies

Carling Technologies EA1-B0-16-670-22B-BF is a 70A magnetic circuit breaker with 5000A breaking capacity. It has corrosion/moisture resistance, operates b/w -40 to 85°C, and rated for 125V DC voltage. Ideal for panel mounting in applications requiring series trip circuit protection.

70 A

5 kA

125 V

2.61 in (66.3 mm)

5.78 in (146.81 mm)

1.026 in (26.06 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Stud

Panel Mount

EA2-B0-24-660-22B-GB by Carling Technologies

EA2-B0-24-660-22B-GB

Carling Technologies

Carling Technologies EA2-B0-24-660-22B-GB is a 60A circuit breaker with 600V AC voltage rating. It features corrosion/moisture resistance, magnetic protection, and CSA/UL standards compliance. Ideal for panel mounting in applications requiring series trip functionality and high breaking capacity up to 10000A.

60 A

10 kA

600 V

2.61 in (66.3 mm)

5.78 in (146.81 mm)

2.093 in (53.15 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Stud

Panel Mount

EA3-B0-62-650-12B-CC by Carling Technologies

EA3-B0-62-650-12B-CC

Carling Technologies

Carling Technologies EA3-B0-62-650-12B-CC is a 50A circuit breaker with 240V AC voltage rating. It features corrosion/moisture resistance and operates in temperatures from -40°C to 85°C. Ideal for panel mounting, it has a breaking capacity of 5000A and uses a magnetic actuator for series trip functionality.

50 A

5 kA

240 V

2.61 in (66.3 mm)

5.78 in (146.81 mm)

3.138 in (79.7 mm)

Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Stud

Panel Mount

EA3-B0-64-475-22A-DF by Carling Technologies

EA3-B0-64-475-22A-DF

Carling Technologies

MAGNETIC CIRCUIT BREAKER; Mounting Feature: PANEL MOUNT; Rated AC Voltage: 240 V; Rated Current: 7.5 A; Terminal Shape: STUD; Rated Breaking Capacity: 5000 A;

7.5 A

5 kA

240 V

2.61 in (66.3 mm)

5.78 in (146.81 mm)

3.138 in (79.7 mm)

Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Stud

Panel Mount

CA1-B0-14-673-321-I by Carling Technologies

CA1-B0-14-673-321-I

Carling Technologies

CA1-B0-14-673-321-I by Carling Technologies is a 73A magnetic circuit breaker with a rated breaking capacity of 1500A. With corrosion/moisture resistance, it has a max operating temperature of 85°C and min of -40°C. Ideal for panel mounting in applications requiring reliable series trip circuit protection.

73 A

1.5 kA

65 V

1.85 in (47 mm)

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA, UL

Stud

Panel Mount

CA1-B0-14-410-321-MF by Carling Technologies

CA1-B0-14-410-321-MF

Carling Technologies

Carling Technologies CA1-B0-14-410-321-MF is a 1A magnetic circuit breaker with toggle actuator. It offers corrosion/moisture resistance and operates b/w -40 to 85°C. Ideal for panel mounting in applications requiring series trip circuit protection at 80V DC.

1 A

80 V

1.85 in (47 mm)

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Toggle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Stud

Panel Mount

CA3-P0-D4-825-322-MT by Carling Technologies

CA3-P0-D4-825-322-MT

Carling Technologies

Carling Technologies CA3-P0-D4-825-322-MT is a 250A magnetic circuit breaker with corrosion/moisture resistance. Featuring a rated breaking capacity of 10kA, it has a body size of 65.1mm x 57.53mm x 47mm and operates b/w -40°C to 85°C. Ideal for panel mounting in UL-rated applications requiring reliable series trip protection.

250 A

10 kA

80 V

1.85 in (47 mm)

2.563 in (65.1 mm)

2.265 in (57.53 mm)

Handle

Series Trip

3

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

UL

Stud

Panel Mount

CA1-B2-12-620-321-MJ by Carling Technologies

CA1-B2-12-620-321-MJ

Carling Technologies

Carling Technologies CA1-B2-12-620-321-MJ is a 20A magnetic circuit breaker with 10000A breaking capacity. It has a corrosion-resistant body measuring 63.5mm x 19.18in x 47mm, suitable for panel mounting in applications requiring moisture protection and series trip circuit function.

20 A

10 kA

80 V

1.85 in (47 mm)

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; TUV; UL

Stud

Panel Mount