Loading...

Magnetic Circuit Breakers

Circuit Breaker

Available Parts 169

Part# Info Electrical Specifications Physical Dimensions Fuse Characteristics Operational Environment Design and Compliance Mounting and Packing
Part RoHS Manufacturer Description Rated Current Rated Breaking Capacity Rated AC Voltage Rated DC Voltage Body Height Body Length/Diameter Body Width Dimensions Actuator Type Blow Characteristic Trip Time/Delay Circuit Function No. of Poles Circuit Protection Type Additional Features Minimum Operating Temperature Maximum Operating Temperature Environmental Characteristics Reference Standard Manufacturer Series Terminal Shape Mounting Feature Packing Method
W68-X2Q12-15 by TE Connectivity

W68-X2Q12-15

TE Connectivity

TE Connectivity's W68-X2Q12-15 is a 15A magnetic circuit breaker with 277V AC voltage rating and 2.2s trip delay. Featuring quick connect terminals, toggle actuator, and panel mount design, it offers a rated breaking capacity of 5000A. Ideal for series trip applications requiring reliable circuit protection in compact spaces.

15 A

5 kA

277 V

50.8mm X 38.1mm X 51.89mm

Toggle

2.2 s

Series Trip

2

Magnetic Circuit Breaker

Quick Connect

Panel Mount

W68-X2Q12-30 by TE Connectivity

W68-X2Q12-30

TE Connectivity

TE Connectivity's W68-X2Q12-30 is a 30A magnetic circuit breaker with 277V AC voltage rating and 2.2s trip delay. Featuring a toggle actuator and quick connect terminals, it is ideal for panel mounting applications requiring series trip functionality with a rated breaking capacity of 2500A.

30 A

2.5 kA

277 V

Toggle

2.2 s

Series Trip

2

Magnetic Circuit Breaker

Quick Connect

Panel Mount

MS1-B-10-430-2-1CB-A-A by Carling Technologies

MS1-B-10-430-2-1CB-A-A

Carling Technologies

Carling Technologies MS1-B-10-430-2-1CB-A-A is a 3A magnetic circuit breaker with IP68 rating. Featuring toggle actuator, it has a rated breaking capacity of 3000A and operates b/w -40°C to 85°C. Ideal for panel mounting in applications requiring reliable circuit protection.

3 A

3 kA

50 V

1.634 in (41.5 mm)

1.375 in (34.93 mm)

0.656 in (16.66 mm)

Toggle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

IP68

Screw

Panel Mount

MS1-B-14-630-3-1BB-A-A by Carling Technologies

MS1-B-14-630-3-1BB-A-A

Carling Technologies

Carling Technologies MS1-B-14-630-3-1BB-A-A is a 30A magnetic circuit breaker with IP68 rating. Featuring toggle actuator and screw terminals, it has a rated breaking capacity of 3000A. Ideal for panel mounting in applications requiring series trip circuit protection.

30 A

3 kA

50 V

1.634 in (41.5 mm)

1.375 in (34.93 mm)

0.656 in (16.66 mm)

Toggle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

IP68

Screw

Panel Mount

MS1-B-14-630-3-1CB-A-A by Carling Technologies

MS1-B-14-630-3-1CB-A-A

Carling Technologies

Carling Technologies MS1-B-14-630-3-1CB-A-A is a 30A magnetic circuit breaker with IP68 rating. Featuring toggle actuator and screw terminals, it has a rated breaking capacity of 3000A. Ideal for panel mounting in applications requiring series trip circuit protection at temperatures ranging from -40°C to 85°C.

30 A

3 kA

50 V

1.634 in (41.5 mm)

1.375 in (34.93 mm)

0.656 in (16.66 mm)

Toggle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

IP68

Screw

Panel Mount

MS1-B-14-630-3-1CB-A-C by Carling Technologies

MS1-B-14-630-3-1CB-A-C

Carling Technologies

MAGNETIC CIRCUIT BREAKER; Mounting Feature: PANEL MOUNT; Rated DC Voltage: 50 V; Rated Current: 30 A; Terminal Shape: SCREW; No. of Poles: 1;

30 A

3 kA

50 V

1.634 in (41.5 mm)

1.375 in (34.93 mm)

0.656 in (16.66 mm)

Toggle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

IP68

CSA; CUL; UL

Screw

Panel Mount

W68-X2Q12-20 by TE Connectivity

W68-X2Q12-20

TE Connectivity

TE Connectivity's W68-X2Q12-20 is a 20A circuit breaker with rated AC voltage of 277V. Featuring a trip time of 2.2s, it offers standard blow characteristic and magnetic protection. With dimensions of 50.8mm x 38.1mm x 41.66mm, this toggle actuator breaker is ideal for panel mount applications in environments requiring fungus and moisture resistance.

20 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.5 in (38.1 mm)

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W67-X2Q12-10 by TE Connectivity

W67-X2Q12-10

TE Connectivity

TE Connectivity's W67-X2Q12-10 is a 10A circuit breaker with rated AC voltage of 277V and trip time of 2.2s. Its compact dimensions (50.8mm x 19.05mm x 41.66mm) make it ideal for panel mounting applications requiring standard blow characteristic and magnetic protection up to 5000A in series trip circuits.

10 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.75 in (19.05 mm)

2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W67-X2Q12-15 by TE Connectivity

W67-X2Q12-15

TE Connectivity

TE Connectivity's W67-X2Q12-15 is a 15A circuit breaker with rated AC voltage of 277V and trip time of 2.2s. It features quick connect terminals, fungus and moisture resistance, and operates in temperatures from -40°C to 85°C. Ideal for panel mounting applications requiring magnetic circuit protection with CSA and UL standards compliance.

15 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.75 in (19.05 mm)

2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W67-X2Q12-20 by TE Connectivity

W67-X2Q12-20

TE Connectivity

TE Connectivity's W67-X2Q12-20 Circuit Breaker, rated 277V/20A, features a trip time of 2.2s and dimensions of 50.8mm x 19.05mm x 41.66mm. With fungus and moisture resistance, it is ideal for panel mounting in applications requiring magnetic circuit protection with CSA and UL standards compliance.

20 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.75 in (19.05 mm)

2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W67-X2Q12-5 by TE Connectivity

W67-X2Q12-5

TE Connectivity

TE Connectivity's W67-X2Q12-5 is a 5A circuit breaker with a rated AC voltage of 277V and trip time of 2.2s. It features quick connect terminals, fungus and moisture resistance, and operates in temperatures from -40°C to 85°C. Ideal for panel mounting applications requiring magnetic circuit protection with CSA and UL compliance.

5 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.75 in (19.05 mm)

2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W68-X2Q12-3 by TE Connectivity

W68-X2Q12-3

TE Connectivity

TE Connectivity's W68-X2Q12-3 is a 277V circuit breaker with 3A rated current and 2.2s trip time. It features fungus and moisture resistance, toggle actuator, and quick connect terminals. Ideal for panel mounting in applications requiring magnetic circuit protection with CSA and UL standards compliance.

3 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.5 in (38.1 mm)

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W68-X2Q12-5 by TE Connectivity

W68-X2Q12-5

TE Connectivity

TE Connectivity's W68-X2Q12-5 is a 5A circuit breaker with 277V AC voltage rating and 2.2s trip delay. Measuring 50.8mm x 38.1mm x 41.66mm, it offers fungus and moisture resistance for panel mounting applications requiring magnetic circuit protection up to 5000A breaking capacity in temperatures ranging from -40°C to 85°C.

5 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.5 in (38.1 mm)

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W68-X2Q12-7 by TE Connectivity

W68-X2Q12-7

TE Connectivity

TE Connectivity's W68-X2Q12-7 is a 7A circuit breaker with 277V AC voltage rating and 2.2s trip time. Measuring 50.8mm x 38.1mm x 41.66mm, it offers standard blow characteristic and toggle actuator for panel mount applications requiring magnetic circuit protection up to 5000A breaking capacity in harsh environments resistant to fungus and moisture per CSA/UL standards.

7 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.5 in (38.1 mm)

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W69-X2Q12-20 by TE Connectivity

W69-X2Q12-20

TE Connectivity

TE Connectivity's W69-X2Q12-20 is a 20A circuit breaker with rated AC voltage of 277V and trip time of 2.2s. It features fungus and moisture resistance, quick connect terminals, and toggle actuator. Ideal for panel mounting in applications requiring magnetic circuit protection with standard blow characteristic.

20 A

5 kA

277 V

1.64 in (41.66 mm)

2.25 in (57.15 mm)

2 in (50.8 mm)

2.25 x 2 x 1.64 in (57.15 x 50.8 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W69-X2Q12-30 by TE Connectivity

W69-X2Q12-30

TE Connectivity

MAGNETIC CIRCUIT BREAKER; Mounting Feature: PANEL MOUNT; Rated AC Voltage: 277 V; Rated Current: 30 A; Terminal Shape: QUICK CONNECT; Trip Time/Delay: 2.2 Seconds;

30 A

2.5 kA

277 V

1.64 in (41.66 mm)

2.25 in (57.15 mm)

2 in (50.8 mm)

2.25 x 2 x 1.64 in (57.15 x 50.8 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W91-X112-30 by TE Connectivity

W91-X112-30

TE Connectivity

TE Connectivity's W91-X112-30 is a 30A circuit breaker with 277V AC voltage rating and 2.2s trip delay. Featuring toggle actuator, it has magnetic protection with 5000A breaking capacity. Ideal for panel mounting in series trip circuits, operating b/w -40°C to 85°C temperature range.

30 A

5 kA

277 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Toggle

2.2 s

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

W92-X112-30 by TE Connectivity

W92-X112-30

TE Connectivity

TE Connectivity's W92-X112-30 is a 30A circuit breaker with rated AC voltage of 277V. Featuring a trip time of 2.2s, it offers moisture resistance and operates in temperatures from -40°C to 85°C. Ideal for panel mounting, this magnetic breaker has a breaking capacity of 5000A and is suitable for series trip applications.

30 A

5 kA

277 V

1.985 in (50.42 mm)

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Toggle

Standard

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Moisture Resistant

CSA; UL; VDE

Stud

Panel Mount

W92-X112-40 by TE Connectivity

W92-X112-40

TE Connectivity

TE Connectivity's W92-X112-40 is a 40A circuit breaker with 277V AC voltage rating and 2.2s trip delay. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 5000A. Ideal for panel mounting applications in series trip circuits, this toggle actuator breaker operates b/w -40°C to 85°C temperatures.

40 A

5 kA

277 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Toggle

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

W93-X112-40V by TE Connectivity

W93-X112-40V

TE Connectivity

TE Connectivity's W93-X112-40V is a 250V circuit breaker with a trip time of 2.2s. It has a rated current of 40A and can operate in temperatures ranging from -40°C to 85°C. This magnetic circuit breaker, with a rated breaking capacity of 2000A, is suitable for panel mounting and series trip applications.

40 A

2 kA

250 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Toggle

2.2 s

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

J7MN-3R-6 by Omron

J7MN-3R-6

Omron

MAGNETIC CIRCUIT BREAKER; Mounting Feature: PANEL MOUNT/DIN-RAIL MOUNT; Rated AC Voltage: 690 V; Rated Current: 6 A; Terminal Shape: SCREW; Environmental Characteristics: IP20;

6 A

100 kA

690 V

3.858 in (98 mm)

3.366 in (85.5 mm)

1.772 in (45 mm)

3.366 x 1.772 x 3.858 in (85.5 x 45 x 98 mm)

Manual On/Off

Under Voltage Release

3

Magnetic Circuit Breaker

-20 °C (-4 °F)

60 °C (140 °F)

IP20

CSA; UL

Screw

DIN Rail And Panel Mount

W67-X2T52-50 by TE Connectivity

W67-X2T52-50

TE Connectivity

TE Connectivity's W67-X2T52-50 is a 50A magnetic circuit breaker with a trip time of 2.2s and rated DC voltage of 65V. Featuring a screw terminal shape, toggle actuator type, and panel mounting feature, it is ideal for series trip circuit protection applications.

50 A

65 V

Toggle

2.2 s

Series Trip

1

Magnetic Circuit Breaker

Screw

Panel Mount

AA1-B0-26-430-1B1-C by Carling Technologies

AA1-B0-26-430-1B1-C

Carling Technologies

Carling Technologies AA1-B0-26-430-1B1-C is a 3A magnetic circuit breaker with 277V AC voltage rating. It features corrosion/moisture resistance, quick connect terminals, and a handle actuator. Ideal for panel mounting in applications requiring series trip circuit protection up to 5000A breaking capacity.

3 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

CA1-B0-12-225-321-D by Carling Technologies

CA1-B0-12-225-321-D

Carling Technologies

CA1-B0-12-225-321-D by Carling Technologies is a 480V circuit breaker with 0.25A rated current and 10000A breaking capacity. Featuring a handle actuator, it is ideal for panel mounting applications requiring magnetic protection in series trip circuits.

250 mA

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B0-16-625-622-D by Carling Technologies

CA1-B0-16-625-622-D

Carling Technologies

Carling Technologies CA1-B0-16-625-622-D is a 25A magnetic circuit breaker with 480V AC and 150V DC voltage ratings. Featuring a compact design of 47x63.5 mm, it has a breaking capacity of 10kA. Ideal for panel mounting in various applications requiring reliable circuit protection within -40 to 85°C temperature range.

25 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B0-26-210-412-D by Carling Technologies

CA1-B0-26-210-412-D

Carling Technologies

Carling Technologies CA1-B0-26-210-412-D is a 250V magnetic circuit breaker with 0.1A rated current and 5000A breaking capacity. Ideal for panel mounting, it offers corrosion/moisture resistance and operates in temperatures from -40 to 85°C.

100 mA

5 kA

250 V

1.85 in (47 mm)

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Stud

Panel Mount

CA1-B0-32-410-311-C by Carling Technologies

CA1-B0-32-410-311-C

Carling Technologies

Carling Technologies CA1-B0-32-410-311-C is a 1A circuit breaker with 480V AC and 150V DC ratings. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10000A. Ideal for panel mounting applications in various industries due to its UL certification and series trip circuit function.

1 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B0-32-810-AG2-C by Carling Technologies

CA1-B0-32-810-AG2-C

Carling Technologies

Carling Technologies CA1-B0-32-810-AG2-C is a 100A magnetic circuit breaker with 480V AC and 150V DC voltage ratings. Featuring a compact design, it is ideal for panel mounting applications in various industries. With UL certification, this series trip breaker ensures reliable circuit protection from -40°C to 85°C temperatures.

100 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B0-34-450-A21-C by Carling Technologies

CA1-B0-34-450-A21-C

Carling Technologies

CA1-B0-34-450-A21-C by Carling Technologies is a 5A circuit breaker with a rated AC voltage of 480V. Featuring a magnetic circuit protection type, it has a max operating temperature of 85°C and is designed for panel mounting applications. With UL reference standard, this series trip breaker has a rated breaking capacity of 10000A.

5 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B0-46-625-622-C by Carling Technologies

CA1-B0-46-625-622-C

Carling Technologies

CA1-B0-46-625-622-C by Carling Technologies is a 25A magnetic circuit breaker with a rated AC voltage of 480V. Featuring a compact body size of 47x19.05x63.5mm, it has a high breaking capacity of 10kA. Ideal for panel mounting applications in various industries, this UL-certified circuit breaker operates b/w -40°C to 85°C efficiently.

25 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B2-12-610-121-C by Carling Technologies

CA1-B2-12-610-121-C

Carling Technologies

Carling Technologies CA1-B2-12-610-121-C is a 10A magnetic circuit breaker with 480V AC and 150V DC voltage ratings. Featuring a compact design of 47x63.5 mm, it is ideal for panel mounting applications requiring series trip circuit protection up to 10000A breaking capacity.

10 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B2-12-610-121-D by Carling Technologies

CA1-B2-12-610-121-D

Carling Technologies

CA1-B2-12-610-121-D by Carling Technologies is a 10A circuit breaker with 480V AC and 150V DC ratings. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10000A. Ideal for panel mounting applications, it operates in temperatures ranging from -40°C to 85°C.

10 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B2-12-610-121-MG by Carling Technologies

CA1-B2-12-610-121-MG

Carling Technologies

Carling Technologies CA1-B2-12-610-121-MG is a 10A magnetic circuit breaker with 240V AC and 80V DC ratings. Featuring a compact design of 47x19.05x63.5mm, it has a series trip function and UL certification for panel mounting applications in various industries.

10 A

10 kA

240 V

80 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B2-12-620-321-C by Carling Technologies

CA1-B2-12-620-321-C

Carling Technologies

Carling Technologies CA1-B2-12-620-321-C is a 20A magnetic circuit breaker with 480V AC and 150V DC ratings. Featuring a panel mount design, it has a compact body measuring 47x19.05x63.5mm (LxWxH). Ideal for UL-rated applications requiring series trip protection in temperatures ranging from -40°C to 85°C.

20 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B2-34-450-A21-C by Carling Technologies

CA1-B2-34-450-A21-C

Carling Technologies

Carling Technologies CA1-B2-34-450-A21-C is a 5A circuit breaker with 480V AC and 150V DC ratings. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10000A. Ideal for panel mounting applications in various industries due to its compact dimensions and UL certification.

5 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Screw

Panel Mount

CA2-B0-34-615-121-C by Carling Technologies

CA2-B0-34-615-121-C

Carling Technologies

Carling Technologies CA2-B0-34-615-121-C is a 15A circuit breaker with 480V AC voltage rating. Featuring magnetic protection, it has a breaking capacity of 10kA and operates b/w -40°C to 85°C. Ideal for panel mounting in UL-standard applications requiring reliable series trip functionality.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B0-34-615-121-E by Carling Technologies

CA2-B0-34-615-121-E

Carling Technologies

Carling Technologies CA2-B0-34-615-121-E is a 15A magnetic circuit breaker with 480V AC and 150V DC ratings. Featuring a panel mount design, it has a compact body measuring 47x38.48x63.5mm, suitable for series trip applications in various industries.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B0-34-615-121-I by Carling Technologies

CA2-B0-34-615-121-I

Carling Technologies

Carling Technologies CA2-B0-34-615-121-I is a 15A magnetic circuit breaker with 480V AC and 150V DC ratings. Featuring a compact design (47x38.48x63.5 mm), it has a high breaking capacity of 10000A. Ideal for panel mounting in series trip circuits, UL certified for applications requiring reliable overcurrent protection up to 85°C and down to -40°C.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B2-12-610-121-C by Carling Technologies

CA2-B2-12-610-121-C

Carling Technologies

Carling Technologies CA2-B2-12-610-121-C is a 10A circuit breaker with 480V AC and 150V DC ratings. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10000A. Ideal for panel mounting applications in UL standard circuits, with a temperature range from -40°C to 85°C.

10 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B2-46-635-622-E by Carling Technologies

CA2-B2-46-635-622-E

Carling Technologies

Carling Technologies CA2-B2-46-635-622-E is a 35A circuit breaker with 480V AC voltage rating. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10kA. Ideal for panel mounting in applications requiring series trip functionality and UL compliance.

35 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA3-B0-22-620-122-D by Carling Technologies

CA3-B0-22-620-122-D

Carling Technologies

Carling Technologies CA3-B0-22-620-122-D is a 20A magnetic circuit breaker with 480V AC and 150V DC ratings. Featuring a panel mount design, it has a compact body measuring 47x57.53x63.5mm, making it ideal for series trip applications in various industries.

20 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

2.265 in (57.53 mm)

Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

MA1-4-14-610-1-A22-B-M by Carling Technologies

MA1-4-14-610-1-A22-B-M

Carling Technologies

Carling Technologies MA1-4-14-610-1-A22-B-M is a 10A magnetic circuit breaker with 600A rated breaking capacity. It is chemical/corrosion/moisture resistant, UL/CSA certified, and operates b/w -40 to 85°C. Ideal for panel mounting in applications requiring series trip circuit protection.

10 A

600 A

80 V

1.53 in (38.86 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Rocker

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

UL; CSA

Quick Connect

Panel Mount

MD1-B-34-610-1-A42-B-C by Carling Technologies

MD1-B-34-610-1-A42-B-C

Carling Technologies

Carling Technologies MD1-B-34-610-1-A42-B-C is a 10A circuit breaker with 125V AC voltage rating. It features chemical/corrosion/moisture resistance, quick connect terminals, and rocker actuator. Ideal for panel mounting applications requiring magnetic circuit protection with UL/CSA standards compliance.

10 A

1 kA

125 V

80 V

1.53 in (38.86 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Rocker

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

UL; CSA

Quick Connect

Panel Mount

ME1-4-14-610-1-A16-2-T by Carling Technologies

ME1-4-14-610-1-A16-2-T

Carling Technologies

Carling Technologies ME1-4-14-610-1-A16-2-T is a 10A magnetic circuit breaker with 600A rated breaking capacity. It is chemical/corrosion/moisture resistant, UL standard compliant, and has quick connect terminals. Ideal for panel mounting in applications requiring series trip circuit protection at temperatures ranging from -40 to 85°C.

10 A

600 A

80 V

1.53 in (38.86 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Rocker

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

UL

Quick Connect

Panel Mount

MF1-B-32-410-1-CC6-2-D by Carling Technologies

MF1-B-32-410-1-CC6-2-D

Carling Technologies

Carling Technologies' MF1-B-32-410-1-CC6-2-D is a 1A circuit breaker with 250V AC and 80V DC ratings. It features an illuminated rocker actuator, chemical/corrosion/moisture resistance, and quick connect terminals. Ideal for panel mounting in applications requiring series trip circuit protection up to 1000A breaking capacity.

1 A

1 kA

250 V

80 V

1.53 in (38.86 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Illuminated Rocker

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

CSA; UL; VDE

Quick Connect

Panel Mount

MF2-B-64-622-2-CC6-B-C by Carling Technologies

MF2-B-64-622-2-CC6-B-C

Carling Technologies

Carling Technologies MF2-B-64-622-2-CC6-B-C is a 22A circuit breaker with 250V AC voltage rating. It features chemical/corrosion/moisture resistance, screw terminals, and an illuminated rocker actuator. Ideal for panel mounting in applications requiring series trip circuit protection up to 1000A breaking capacity.

22 A

1 kA

250 V

1.53 in (38.86 mm)

1.375 in (34.93 mm)

1.304 in (33.12 mm)

Illuminated Rocker

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

UL; CSA

Screw

Panel Mount

MG1-B-32-410-1-CC1-B-C by Carling Technologies

MG1-B-32-410-1-CC1-B-C

Carling Technologies

Carling Technologies' MG1-B-32-410-1-CC1-B-C is a 125V, 1A circuit breaker with chemical/corrosion/moisture resistance. Featuring an illuminated rocker actuator and quick connect terminals, it has a rated breaking capacity of 1000A. Ideal for panel mounting in applications requiring series trip circuit protection.

1 A

1 kA

125 V

80 V

1.53 in (38.86 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Illuminated Rocker

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

UL; CSA

Quick Connect

Panel Mount

MT1-B-32-410-1-C21-B-C by Carling Technologies

MT1-B-32-410-1-C21-B-C

Carling Technologies

Carling Technologies' MT1-B-32-410-1-C21-B-C is a 1A magnetic circuit breaker with 125V AC and 80V DC ratings. It features chemical/corrosion/moisture resistance, quick connect terminals, and push-pull actuator for panel mounting applications. Operating b/w -40°C to 85°C, it offers a high breaking capacity of 1000A in series trip circuits.

1 A

1 kA

125 V

80 V

1.484 in (37.69 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Push-Pull

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

UL; CSA

Quick Connect

Panel Mount