Part# Info Electrical Specifications Physical Dimensions Fuse Characteristics Operational Environment Design and Compliance Mounting and Packing
Part RoHS Manufacturer Description Rated Current Rated Breaking Capacity Rated AC Voltage Rated DC Voltage Body Height Body Length/Diameter Body Width Dimensions Actuator Type Blow Characteristic Trip Time/Delay Circuit Function No. of Poles Circuit Protection Type Additional Features Minimum Operating Temperature Maximum Operating Temperature Environmental Characteristics Reference Standard Manufacturer Series Terminal Shape Mounting Feature Packing Method
W91-X112-2 by TE Connectivity

W91-X112-2

TE Connectivity

TE Connectivity's W91-X112-2 is a 2A magnetic circuit breaker with 277V AC voltage rating and 2.2s trip time. Featuring toggle actuator and panel mount, it is ideal for series trip applications in environments ranging from -40°C to 85°C.

2 A

5 kA

277 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Toggle

2.2 s

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

J7MN-3R-E63 by Omron

J7MN-3R-E63

Omron

MAGNETIC CIRCUIT BREAKER; Mounting Feature: PANEL MOUNT/DIN-RAIL MOUNT; Rated AC Voltage: 690 V; Rated Current: .63 A; Terminal Shape: SCREW; Circuit Function: UNDER VOLTAGE RELEASE;

630 mA

100 kA

690 V

3.858 in (98 mm)

3.366 in (85.5 mm)

1.772 in (45 mm)

3.366 x 1.772 x 3.858 in (85.5 x 45 x 98 mm)

Manual On/Off

Under Voltage Release

3

Magnetic Circuit Breaker

-20 °C (-4 °F)

60 °C (140 °F)

IP20

CSA; UL

Screw

DIN Rail And Panel Mount

CA3-B0-20-615-121-C by Carling Technologies

CA3-B0-20-615-121-C

Carling Technologies

Carling Technologies CA3-B0-20-615-121-C is a 250V, 15A magnetic circuit breaker with corrosion resistance. Featuring a stud terminal shape and panel mount, it has a rated breaking capacity of 3000A. Ideal for applications requiring series trip circuit protection in environments with temperatures ranging from -40°C to 85°C.

15 A

3 kA

250 V

1.85 in (47 mm)

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA, UL

Stud

Panel Mount

CB4-B0-24-615-1C1-D by Carling Technologies

CB4-B0-24-615-1C1-D

Carling Technologies

Carling Technologies CB4-B0-24-615-1C1-D is a 15A magnetic circuit breaker with 250V AC voltage rating. It features corrosion/moisture resistance, stud terminals, and a series trip circuit function. Ideal for panel mounting applications, it meets CSA, UL, and VDE standards while offering a rated breaking capacity of 3000A.

15 A

3 kA

250 V

1.85 in (47 mm)

2.5 in (63.5 mm)

3.015 in (76.58 mm)

Handle

Series Trip

4

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA, UL, VDE

Stud

Panel Mount

MF1-B-32-410-1-CE3-B-C by Carling Technologies

MF1-B-32-410-1-CE3-B-C

Carling Technologies

MAGNETIC CIRCUIT BREAKER; Mounting Feature: PANEL MOUNT; Rated AC Voltage: 125 V; Rated DC Voltage: 80 V; Rated Current: 1 A; Terminal Shape: QUICK CONNECT;

1 A

360 A

125 V

80 V

1.53 in (38.86 mm)

1.56 in (39.62 mm)

0.77 in (19.56 mm)

Rocker

Series Trip

1

Magnetic Circuit Breaker

Rated breaking capacity at 80 VDC: 600 A

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA, UL

Quick Connect

Panel Mount

CA1-B0-34-615-121-D by Carling Technologies

CA1-B0-34-615-121-D

Carling Technologies

CA1-B0-34-615-121-D by Carling Technologies is a 15A magnetic circuit breaker with a rated AC voltage of 250V. It features corrosion/moisture resistance and operates in temperatures ranging from -40 to 85°C. Ideal for panel mounting, this breaker has a rated breaking capacity of 5000A and is suitable for series trip applications.

15 A

5 kA

250 V

80 V

1.85 in (47 mm)

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Stud

Panel Mount

CA2-B0-34-615-121-D by Carling Technologies

CA2-B0-34-615-121-D

Carling Technologies

Carling Technologies CA2-B0-34-615-121-D is a 15A circuit breaker with 480V AC voltage rating. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10kA. Ideal for panel mounting applications in UL standard compliant setups.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

DA2-B0-34-450-121-C by Carling Technologies

DA2-B0-34-450-121-C

Carling Technologies

Carling Technologies DA2-B0-34-450-121-C is a 250V, 5A magnetic circuit breaker with moisture resistance. Featuring a toggle handle actuator and screw terminals, it has a rated breaking capacity of 1500A. Ideal for panel mounting in applications requiring series trip circuit protection under temperatures ranging from -40°C to 85°C.

5 A

1.5 kA

250 V

2.165 in (54.99 mm)

3.612 in (91.75 mm)

1.515 in (38.48 mm)

Toggle Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Moisture Resistant

CSA; UL

Screw

Panel Mount

DA3-B0-20-615-121-C by Carling Technologies

DA3-B0-20-615-121-C

Carling Technologies

Carling Technologies DA3-B0-20-615-121-C is a 15A magnetic circuit breaker with 277V AC voltage rating. Featuring moisture-resistant design, it has a breaking capacity of 5000A and operates in temperatures ranging from -40°C to 85°C. Ideal for panel mounting applications requiring series trip circuit protection.

15 A

5 kA

277 V

2.165 in (54.99 mm)

3.612 in (91.75 mm)

2.265 in (57.53 mm)

Toggle Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Moisture Resistant

CSA; UL

Screw

Panel Mount

FA3-P0-14-870-22B-BT by Carling Technologies

FA3-P0-14-870-22B-BT

Carling Technologies

Carling Technologies FA3-P0-14-870-22B-BT is a 700A magnetic circuit breaker with 50000A rated breaking capacity. It features corrosion/moisture resistance, screw terminals, and UL certification. Ideal for panel mounting in applications requiring series trip circuit protection at temperatures ranging from -40°C to 85°C.

700 A

50 kA

125 V

2.968 in (75.38 mm)

7.125 in (180.98 mm)

4.5 in (114.3 mm)

Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

UL

Screw

Panel Mount

EA1-B0-16-670-22B-BB by Carling Technologies

EA1-B0-16-670-22B-BB

Carling Technologies

Carling Technologies EA1-B0-16-670-22B-BB is a 70A magnetic circuit breaker with 5000A rated breaking capacity. It features corrosion/moisture resistance and operates b/w -40°C to 85°C. Ideal for panel mounting in applications requiring reliable series trip circuit protection.

70 A

5 kA

125 V

2.61 in (66.3 mm)

5.78 in (146.81 mm)

1.026 in (26.06 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Stud

Panel Mount

EA1-B0-16-670-22B-BF by Carling Technologies

EA1-B0-16-670-22B-BF

Carling Technologies

Carling Technologies EA1-B0-16-670-22B-BF is a 70A magnetic circuit breaker with 5000A breaking capacity. It has corrosion/moisture resistance, operates b/w -40 to 85°C, and rated for 125V DC voltage. Ideal for panel mounting in applications requiring series trip circuit protection.

70 A

5 kA

125 V

2.61 in (66.3 mm)

5.78 in (146.81 mm)

1.026 in (26.06 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Stud

Panel Mount

EA2-B0-24-660-22B-GB by Carling Technologies

EA2-B0-24-660-22B-GB

Carling Technologies

Carling Technologies EA2-B0-24-660-22B-GB is a 60A circuit breaker with 600V AC voltage rating. It features corrosion/moisture resistance, magnetic protection, and CSA/UL standards compliance. Ideal for panel mounting in applications requiring series trip functionality and high breaking capacity up to 10000A.

60 A

10 kA

600 V

2.61 in (66.3 mm)

5.78 in (146.81 mm)

2.093 in (53.15 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Stud

Panel Mount

EA3-B0-62-650-12B-CC by Carling Technologies

EA3-B0-62-650-12B-CC

Carling Technologies

Carling Technologies EA3-B0-62-650-12B-CC is a 50A circuit breaker with 240V AC voltage rating. It features corrosion/moisture resistance and operates in temperatures from -40°C to 85°C. Ideal for panel mounting, it has a breaking capacity of 5000A and uses a magnetic actuator for series trip functionality.

50 A

5 kA

240 V

2.61 in (66.3 mm)

5.78 in (146.81 mm)

3.138 in (79.7 mm)

Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Stud

Panel Mount

EA3-B0-64-475-22A-DF by Carling Technologies

EA3-B0-64-475-22A-DF

Carling Technologies

MAGNETIC CIRCUIT BREAKER; Mounting Feature: PANEL MOUNT; Rated AC Voltage: 240 V; Rated Current: 7.5 A; Terminal Shape: STUD; Rated Breaking Capacity: 5000 A;

7.5 A

5 kA

240 V

2.61 in (66.3 mm)

5.78 in (146.81 mm)

3.138 in (79.7 mm)

Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Stud

Panel Mount

CA1-B0-14-673-321-I by Carling Technologies

CA1-B0-14-673-321-I

Carling Technologies

CA1-B0-14-673-321-I by Carling Technologies is a 73A magnetic circuit breaker with a rated breaking capacity of 1500A. With corrosion/moisture resistance, it has a max operating temperature of 85°C and min of -40°C. Ideal for panel mounting in applications requiring reliable series trip circuit protection.

73 A

1.5 kA

65 V

1.85 in (47 mm)

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA, UL

Stud

Panel Mount

CA1-B0-14-410-321-MF by Carling Technologies

CA1-B0-14-410-321-MF

Carling Technologies

Carling Technologies CA1-B0-14-410-321-MF is a 1A magnetic circuit breaker with toggle actuator. It offers corrosion/moisture resistance and operates b/w -40 to 85°C. Ideal for panel mounting in applications requiring series trip circuit protection at 80V DC.

1 A

80 V

1.85 in (47 mm)

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Toggle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Stud

Panel Mount

CA3-P0-D4-825-322-MT by Carling Technologies

CA3-P0-D4-825-322-MT

Carling Technologies

Carling Technologies CA3-P0-D4-825-322-MT is a 250A magnetic circuit breaker with corrosion/moisture resistance. Featuring a rated breaking capacity of 10kA, it has a body size of 65.1mm x 57.53mm x 47mm and operates b/w -40°C to 85°C. Ideal for panel mounting in UL-rated applications requiring reliable series trip protection.

250 A

10 kA

80 V

1.85 in (47 mm)

2.563 in (65.1 mm)

2.265 in (57.53 mm)

Handle

Series Trip

3

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

UL

Stud

Panel Mount

CA1-B2-12-620-321-MJ by Carling Technologies

CA1-B2-12-620-321-MJ

Carling Technologies

Carling Technologies CA1-B2-12-620-321-MJ is a 20A magnetic circuit breaker with 10000A breaking capacity. It has a corrosion-resistant body measuring 63.5mm x 19.18in x 47mm, suitable for panel mounting in applications requiring moisture protection and series trip circuit function.

20 A

10 kA

80 V

1.85 in (47 mm)

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; TUV; UL

Stud

Panel Mount

CA3-P0-D4-922-A21-MT by Carling Technologies

CA3-P0-D4-922-A21-MT

Carling Technologies

Carling Technologies CA3-P0-D4-922-A21-MT is a 225A magnetic circuit breaker with 10000A breaking capacity. Featuring corrosion-resistant body, it has a rated DC voltage of 80V and operates b/w -40 to 85°C. Ideal for panel mounting in series trip applications, compliant with UL standards.

225 A

10 kA

80 V

1.85 in (47 mm)

2.563 in (65.1 mm)

2.265 in (57.53 mm)

Handle

Series Trip

3

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

UL

Stud

Panel Mount

AA1-B0-26-625-3D1-C by Carling Technologies

AA1-B0-26-625-3D1-C

Carling Technologies

Carling Technologies AA1-B0-26-625-3D1-C is a 25A magnetic circuit breaker with 277V AC voltage rating. It features corrosion/moisture resistance, toggle actuator, and screw terminals. Ideal for panel mounting in applications requiring series trip circuit protection up to 5000A breaking capacity.

25 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.755 in (19.18 mm)

Toggle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

AA1-B0-34-625-3B1-C by Carling Technologies

AA1-B0-34-625-3B1-C

Carling Technologies

Carling Technologies AA1-B0-34-625-3B1-C is a 25A magnetic circuit breaker with 277V AC and 80V DC ratings. It features corrosion/moisture resistance, toggle actuator, and screw terminals. Ideal for panel mounting in applications requiring series trip circuit protection with CSA/UL standards compliance.

25 A

5 kA

277 V

80 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.755 in (19.18 mm)

Toggle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

203-22-1-66-103-4-1-1 by Sensata Technologies

203-22-1-66-103-4-1-1

Sensata Technologies

Sensata Technologies' 203-22-1-66-103-4-1-1 Circuit Breaker has a rated AC voltage of 250V, with a max operating temperature of 85°C and a breaking capacity of 2000A. It features a quick connect terminal shape, rocker actuator type, and is ideal for panel mount applications requiring series trip circuit protection.

2 kA

250 V

1.77 in (44.96 mm)

2 in (50.8 mm)

1.54 in (39.12 mm)

Rocker

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

CSA; UL

Quick Connect

Panel Mount

GFL2D200302 by Altech

GFL2D200302

Altech

Altech GFL2D200302 is a 20A magnetic circuit breaker with 240V AC voltage rating. Featuring a toggle actuator and DIN rail mounting, it has a rated breaking capacity of 10kA. Ideal for circuit protection in industrial applications meeting CUL and UL standards.

20 A

10 kA

240 V

2.362 in (60 mm)

4.134 in (105 mm)

1.378 in (35 mm)

Toggle

Trip

1

Magnetic Circuit Breaker

CUL; UL

Snap On

DIN Rail Mount

NRBM3100-20AAA by Idec

NRBM3100-20AAA

Idec

Idec's NRBM3100-20AAA is a 250V, 20A magnetic circuit breaker with a rated breaking capacity of 1000A. Featuring a lever actuator and panel mount, it is ideal for series trip applications in various industries. Compliant with CCC, CE, CUL, PSE, UL, VDE standards and operates b/w -40°C to 85°C.

20 A

1 kA

250 V

1.87 in (47.5 mm)

2.48 in (63 mm)

2.256 in (57.3 mm)

Lever

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

CCC; CE; CUL; PSE; UL; VDE

Stud

Panel Mount