Loading...

Double Pole Circuit Breaker

Circuit Breaker

Available Parts 127

Part# Info Electrical Specifications Physical Dimensions Fuse Characteristics Operational Environment Design and Compliance Mounting and Packing
Part RoHS Manufacturer Description Rated Current Rated Breaking Capacity Rated AC Voltage Rated DC Voltage Body Height Body Length/Diameter Body Width Dimensions Actuator Type Blow Characteristic Trip Time/Delay Circuit Function No. of Poles Circuit Protection Type Additional Features Minimum Operating Temperature Maximum Operating Temperature Environmental Characteristics Reference Standard Manufacturer Series Terminal Shape Mounting Feature Packing Method
W68-X2Q12-15 by TE Connectivity

W68-X2Q12-15

TE Connectivity

TE Connectivity's W68-X2Q12-15 is a 15A magnetic circuit breaker with 277V AC voltage rating and 2.2s trip delay. Featuring quick connect terminals, toggle actuator, and panel mount design, it offers a rated breaking capacity of 5000A. Ideal for series trip applications requiring reliable circuit protection in compact spaces.

15 A

5 kA

277 V

50.8mm X 38.1mm X 51.89mm

Toggle

2.2 s

Series Trip

2

Magnetic Circuit Breaker

Quick Connect

Panel Mount

W68-X2Q12-30 by TE Connectivity

W68-X2Q12-30

TE Connectivity

TE Connectivity's W68-X2Q12-30 is a 30A magnetic circuit breaker with 277V AC voltage rating and 2.2s trip delay. Featuring a toggle actuator and quick connect terminals, it is ideal for panel mounting applications requiring series trip functionality with a rated breaking capacity of 2500A.

30 A

2.5 kA

277 V

Toggle

2.2 s

Series Trip

2

Magnetic Circuit Breaker

Quick Connect

Panel Mount

W33-T2N1Q-20 by TE Connectivity

W33-T2N1Q-20

TE Connectivity

TE Connectivity's W33-T2N1Q-20 is a 20A thermal circuit breaker with a rated AC voltage of 250V. It has a trip time of 3 seconds and a rated breaking capacity of 1000A. This circuit breaker is commonly used for panel mount applications requiring series trip protection.

20 A

1 kA

250 V

50 V

1.724 in (43.79 mm)

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Rocker

3 s

Series Trip

2

Thermal Circuit Breaker

Quick Connect

Panel Mount

W33-T4B1Q-10 by TE Connectivity

W33-T4B1Q-10

TE Connectivity

TE Connectivity's W33-T4B1Q-10 is a 10A thermal circuit breaker with 250V AC and 50V DC ratings. Featuring a quick connect terminal shape, it has a trip time of 3s and rated breaking capacity of 1000A. Ideal for panel mounting in series trip circuits, this rocker actuator device ensures reliable circuit protection.

10 A

1 kA

250 V

50 V

1.724 in (43.79 mm)

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Rocker

3 s

Series Trip

2

Thermal Circuit Breaker

Quick Connect

Panel Mount

W33-T4B1Q-5 by TE Connectivity

W33-T4B1Q-5

TE Connectivity

TE Connectivity's W33-T4B1Q-5 is a 5A thermal circuit breaker with 250V AC and 50V DC ratings. Featuring a quick connect terminal shape, it has a trip time of 3s and breaking capacity of 1000A. Ideal for panel mounting in series trip circuits, this rocker actuator device ensures reliable circuit protection.

5 A

1 kA

250 V

50 V

1.724 in (43.79 mm)

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Rocker

3 s

Series Trip

2

Thermal Circuit Breaker

Quick Connect

Panel Mount

3120-F321-P7T1-W01D-20A by E-t-a Elektrotechnische Apparate

3120-F321-P7T1-W01D-20A

E-t-a Elektrotechnische Apparate

3120-F321-P7T1-W01D-20A by E-t-a Elektrotechnische Apparate is a 20A thermal circuit breaker with a rated AC voltage of 250V. Featuring quick connect terminals and a corrosion-resistant body, it is ideal for panel mounting applications. With a compact size of 54mm x 21mm x 33mm and an operating temperature range from -30°C to 60°C, this rocker actuator circuit breaker meets CCC, CSA, UL, and VDE standards.

20 A

20 A

250 V

50 V

1.299 in (33 mm)

2.126 in (54 mm)

0.827 in (21 mm)

2.126 x 0.827 x 1.299 in (54 x 21 x 33 mm)

Rocker

Manual On/Off

2

Thermal Circuit Breaker

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant

CCC; CSA; UL; VDE

Quick Connect

Panel Mount

3120-F323-P7T1-W01D-5A by E-t-a Elektrotechnische Apparate

3120-F323-P7T1-W01D-5A

E-t-a Elektrotechnische Apparate

3120-F323-P7T1-W01D-5A by E-t-a Elektrotechnische Apparate is a 5A thermal circuit breaker with a rated AC voltage of 250V. Featuring quick connect terminals and a compact size of 54mm x 21mm x 33mm, it is ideal for panel mounting applications. With corrosion-resistant properties and a wide operating temperature range (-30°C to 60°C), this circuit breaker ensures reliable performance in various environments.

5 A

5 A

250 V

50 V

1.299 in (33 mm)

2.126 in (54 mm)

0.827 in (21 mm)

2.126 x 0.827 x 1.299 in (54 x 21 x 33 mm)

Rocker

Manual On/Off

2

Thermal Circuit Breaker

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant

CCC; CSA; UL; VDE

Quick Connect

Panel Mount

3120-F324-P7T1-W01D-10A by E-t-a Elektrotechnische Apparate

3120-F324-P7T1-W01D-10A

E-t-a Elektrotechnische Apparate

3120-F324-P7T1-W01D-10A by E-t-a Elektrotechnische Apparate is a 10A thermal circuit breaker with a rated AC voltage of 250V. Featuring quick connect terminals, it is corrosion resistant and has a max operating temperature of 60°C. Ideal for panel mounting applications, this circuit breaker has a rated breaking capacity of 100A.

10 A

100 A

250 V

50 V

1.299 in (33 mm)

2.205 in (56 mm)

0.827 in (21 mm)

2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm)

Rocker

Manual On/Off

2

Thermal Circuit Breaker

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant

CCC; CSA; UL; VDE

Quick Connect

Panel Mount

3120-F324-P7T1-W01D-6A by E-t-a Elektrotechnische Apparate

3120-F324-P7T1-W01D-6A

E-t-a Elektrotechnische Apparate

3120-F324-P7T1-W01D-6A by E-t-a Elektrotechnische Apparate is a 2-pole circuit breaker with a rated AC voltage of 250V and a rated current of 6A. It has a corrosion-resistant body and quick connect terminals, making it suitable for panel mounting applications.

6 A

6 A

250 V

50 V

1.299 in (33 mm)

2.205 in (56 mm)

0.827 in (21 mm)

2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm)

Rocker

Manual On/Off

2

Thermal Circuit Breaker

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant

CCC; CSA; UL; VDE

Quick Connect

Panel Mount

W68-X2Q12-20 by TE Connectivity

W68-X2Q12-20

TE Connectivity

TE Connectivity's W68-X2Q12-20 is a 20A circuit breaker with rated AC voltage of 277V. Featuring a trip time of 2.2s, it offers standard blow characteristic and magnetic protection. With dimensions of 50.8mm x 38.1mm x 41.66mm, this toggle actuator breaker is ideal for panel mount applications in environments requiring fungus and moisture resistance.

20 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.5 in (38.1 mm)

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W68-X2Q12-3 by TE Connectivity

W68-X2Q12-3

TE Connectivity

TE Connectivity's W68-X2Q12-3 is a 277V circuit breaker with 3A rated current and 2.2s trip time. It features fungus and moisture resistance, toggle actuator, and quick connect terminals. Ideal for panel mounting in applications requiring magnetic circuit protection with CSA and UL standards compliance.

3 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.5 in (38.1 mm)

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W68-X2Q12-5 by TE Connectivity

W68-X2Q12-5

TE Connectivity

TE Connectivity's W68-X2Q12-5 is a 5A circuit breaker with 277V AC voltage rating and 2.2s trip delay. Measuring 50.8mm x 38.1mm x 41.66mm, it offers fungus and moisture resistance for panel mounting applications requiring magnetic circuit protection up to 5000A breaking capacity in temperatures ranging from -40°C to 85°C.

5 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.5 in (38.1 mm)

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W68-X2Q12-7 by TE Connectivity

W68-X2Q12-7

TE Connectivity

TE Connectivity's W68-X2Q12-7 is a 7A circuit breaker with 277V AC voltage rating and 2.2s trip time. Measuring 50.8mm x 38.1mm x 41.66mm, it offers standard blow characteristic and toggle actuator for panel mount applications requiring magnetic circuit protection up to 5000A breaking capacity in harsh environments resistant to fungus and moisture per CSA/UL standards.

7 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.5 in (38.1 mm)

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

2C2UM by Altech

2C2UM

Altech

The Altech 2C2UM is a 2A thermal magnetic circuit breaker with a rated AC voltage of 277V. It features an IP20 environmental rating and DIN-rail mounting, suitable for under voltage release applications. With a rated breaking capacity of 10000A, it meets CSA, UL, and VDE standards for reliable circuit protection.

2 A

10 kA

277 V

80 V

2.693 in (68.4 mm)

3.516 in (89.3 mm)

1.378 in (35 mm)

Handle

Under Voltage Release

2

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

55 °C (131 °F)

IP20

CSA; UL; VDE

Screw And Snap On

DIN Rail Mount

Bulk

2D20UM by Altech

2D20UM

Altech

Altech's 2D20UM is a 20A thermal magnetic circuit breaker with 277V AC and 80V DC ratings. It features screw and snap-on terminals, DIN-rail mounting, and under voltage release function. Ideal for applications requiring reliable circuit protection in industrial environments with temperature range of -25 to 55°C.

20 A

10 kA

277 V

80 V

2.693 in (68.4 mm)

3.516 in (89.3 mm)

1.378 in (35 mm)

Handle

Under Voltage Release

2

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

55 °C (131 °F)

IP20

CSA; UL; VDE

Screw And Snap On

DIN Rail Mount

Bulk

2D4UM by Altech

2D4UM

Altech

The Altech 2D4UM is a 4A thermal magnetic circuit breaker with a rated AC voltage of 277V. Featuring an IP20 environmental rating, it has a breaking capacity of 10000A and operates within -25 to 55 °C. Ideal for DIN-rail mounting, its under voltage release function makes it suitable for various industrial applications.

4 A

10 kA

277 V

80 V

2.693 in (68.4 mm)

3.516 in (89.3 mm)

1.378 in (35 mm)

Handle

Under Voltage Release

2

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

55 °C (131 °F)

IP20

CSA; UL; VDE

Screw And Snap On

DIN Rail Mount

Bulk

2DU25L by Altech

2DU25L

Altech

The Altech 2DU25L is a 25A circuit breaker with a rated AC voltage of 480V. Featuring thermal magnetic protection, it has a rated breaking capacity of 10kA and operates in temperatures ranging from -25°C to 60°C. Ideal for DIN rail mounting, this device is commonly used in industrial applications requiring reliable circuit protection.

25 A

10 kA

480 V

2.362 in (60 mm)

4.291 in (109 mm)

1.378 in (35 mm)

Toggle Handle

Trip

2

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

60 °C (140 °F)

IP20

CE, CUL, UL

Snap On

DIN Rail Mount

Bulk

2CU5L by Altech

2CU5L

Altech

The Altech 2CU5L Circuit Breaker is rated for 480V AC voltage and has a rated current of 5A. With a thermal magnetic circuit protection type, it offers a high breaking capacity of 10000A. Ideal for DIN rail mounting in applications requiring reliable trip functionality under varying environmental conditions.

5 A

10 kA

480 V

2.362 in (60 mm)

4.291 in (109 mm)

1.378 in (35 mm)

Toggle Handle

Trip

2

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

60 °C (140 °F)

IP20

CE, CUL, UL

Snap On

DIN Rail Mount

Bulk

2C10UL by Altech

2C10UL

Altech

Altech 2C10UL is a 10A circuit breaker with thermal magnetic protection, rated at 480V AC. Featuring a DIN rail mount and toggle handle actuator, it has a breaking capacity of 10000A. Ideal for industrial applications requiring reliable circuit protection in harsh environments.

10 A

10 kA

480 V

2.693 in (68.4 mm)

4.146 in (105.3 mm)

1.378 in (35 mm)

Toggle Handle

Trip

2

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

55 °C (131 °F)

CE, CUL, UL

Snap On

DIN Rail Mount

Bulk

2C6UL by Altech

2C6UL

Altech

The Altech 2C6UL is a 6A circuit breaker with a rated AC voltage of 240V. Featuring thermal magnetic protection, it has a breaking capacity of 10kA and operates within -25 to 55°C. Ideal for DIN rail mounting in various applications requiring reliable circuit protection.

6 A

10 kA

240 V

2.693 in (68.4 mm)

4.146 in (105.3 mm)

1.378 in (35 mm)

Toggle Handle

Trip

2

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

55 °C (131 °F)

CE, CUL, UL

Snap On

DIN Rail Mount

Bulk

2DU10L by Altech

2DU10L

Altech

The Altech 2DU10L is a 10A circuit breaker with a rated AC voltage of 480V. Featuring thermal magnetic protection, it has a breaking capacity of 10000A and operates within -25 to 60 °C. Designed for DIN rail mounting, it is ideal for industrial applications requiring reliable circuit protection.

10 A

10 kA

480 V

2.362 in (60 mm)

4.291 in (109 mm)

1.378 in (35 mm)

Toggle Handle

Trip

2

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

60 °C (140 °F)

IP20

CE, CUL, UL

Snap On

DIN Rail Mount

Bulk

2DU4L by Altech

2DU4L

Altech

The Altech 2DU4L is a 4A circuit breaker with rated AC voltage of 480V. Featuring thermal magnetic protection, it has a breaking capacity of 10kA and operates in temperatures from -25°C to 60°C. Designed for DIN rail mounting, it is ideal for industrial applications requiring reliable circuit protection.

4 A

10 kA

480 V

2.362 in (60 mm)

4.291 in (109 mm)

1.378 in (35 mm)

Toggle Handle

Trip

2

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

60 °C (140 °F)

IP20

CE, CUL, UL

Snap On

DIN Rail Mount

Bulk

2D5UL by Altech

2D5UL

Altech

The Altech 2D5UL is a 480V circuit breaker with a rated current of 5A and thermal magnetic protection. Featuring a DIN rail mounting, it has a breaking capacity of 10kA and operates b/w -25°C to 55°C. Ideal for industrial applications requiring reliable circuit protection in compact spaces.

5 A

10 kA

480 V

2.693 in (68.4 mm)

4.146 in (105.3 mm)

1.378 in (35 mm)

Toggle Handle

Trip

2

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

55 °C (131 °F)

CE, CUL, UL

Snap On

DIN Rail Mount

Bulk

2CU10L by Altech

2CU10L

Altech

The Altech 2CU10L is a 10A circuit breaker with a rated AC voltage of 480V. Featuring thermal magnetic protection, it has a breaking capacity of 10000A and operates within -25 to 60°C. Ideal for DIN rail mounting in applications requiring reliable trip functionality and compliance with CE, CUL, and UL standards.

10 A

10 kA

480 V

2.362 in (60 mm)

4.291 in (109 mm)

1.378 in (35 mm)

Toggle Handle

Trip

2

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

60 °C (140 °F)

IP20

CE, CUL, UL

Snap On

DIN Rail Mount

Bulk

2DU15L by Altech

2DU15L

Altech

The Altech 2DU15L is a 15A circuit breaker with a rated AC voltage of 480V. Featuring thermal magnetic protection, it has a breaking capacity of 10000A and operates within -25 to 60°C. Ideal for DIN rail mounting in applications requiring reliable circuit protection under varying environmental conditions.

15 A

10 kA

480 V

2.362 in (60 mm)

4.291 in (109 mm)

1.378 in (35 mm)

Toggle Handle

Trip

2

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

60 °C (140 °F)

IP20

CE, CUL, UL

Snap On

DIN Rail Mount

Bulk

2C5UL by Altech

2C5UL

Altech

Altech 2C5UL is a 5A circuit breaker with rated AC voltage of 480V. Featuring thermal magnetic protection, it has a breaking capacity of 10kA. With DIN rail mounting, it is ideal for industrial applications requiring reliable circuit protection in compact spaces.

5 A

10 kA

480 V

2.693 in (68.4 mm)

4.146 in (105.3 mm)

1.378 in (35 mm)

Toggle Handle

Trip

2

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

55 °C (131 °F)

CE, CUL, UL

Snap On

DIN Rail Mount

Bulk

2DU8L by Altech

2DU8L

Altech

The Altech 2DU8L is an 8A circuit breaker with a rated AC voltage of 480V, featuring thermal magnetic protection and a breaking capacity of 10kA. With IP20 environmental rating, it is ideal for DIN rail mounting applications requiring reliable circuit protection in industrial settings.

8 A

10 kA

480 V

2.362 in (60 mm)

4.291 in (109 mm)

1.378 in (35 mm)

Toggle Handle

Trip

2

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

60 °C (140 °F)

IP20

CE, CUL, UL

Snap On

DIN Rail Mount

Bulk

2D4UL by Altech

2D4UL

Altech

Altech's 2D4UL Circuit Breaker, rated at 480V AC and 4A, features thermal magnetic protection with a breaking capacity of 10000A. With DIN rail mounting and toggle handle actuator, it is ideal for industrial applications requiring reliable circuit protection in temperatures ranging from -25°C to 55°C.

4 A

10 kA

480 V

2.693 in (68.4 mm)

4.146 in (105.3 mm)

1.378 in (35 mm)

Toggle Handle

Trip

2

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

55 °C (131 °F)

CE, CUL, UL

Snap On

DIN Rail Mount

Bulk

W33-S1N1Q-10 by TE Connectivity

W33-S1N1Q-10

TE Connectivity

TE Connectivity's W33-S1N1Q-10 is a thermal circuit breaker with a rated AC voltage of 250V and a trip time of 3s. It has a body length of 48.01mm and is commonly used for panel mounting in series trip circuits.

10 A

250 V

50 V

1.724 in (43.79 mm)

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Rocker

3 s

Series Trip

2

Thermal Circuit Breaker

Quick Connect

Panel Mount

W33-S1N1Q-5 by TE Connectivity

W33-S1N1Q-5

TE Connectivity

TE Connectivity's W33-S1N1Q-5 is a 5A thermal circuit breaker with 250V AC and 50V DC ratings. Featuring a quick connect terminal shape, it has a trip time of 3s and a breaking capacity of 1000A. Ideal for panel mounting in series trip circuits.

5 A

1 kA

250 V

50 V

1.724 in (43.79 mm)

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Rocker

3 s

Series Trip

2

Thermal Circuit Breaker

Quick Connect

Panel Mount

W92-X112-30 by TE Connectivity

W92-X112-30

TE Connectivity

TE Connectivity's W92-X112-30 is a 30A circuit breaker with rated AC voltage of 277V. Featuring a trip time of 2.2s, it offers moisture resistance and operates in temperatures from -40°C to 85°C. Ideal for panel mounting, this magnetic breaker has a breaking capacity of 5000A and is suitable for series trip applications.

30 A

5 kA

277 V

1.985 in (50.42 mm)

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Toggle

Standard

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Moisture Resistant

CSA; UL; VDE

Stud

Panel Mount

W92-X112-40 by TE Connectivity

W92-X112-40

TE Connectivity

TE Connectivity's W92-X112-40 is a 40A circuit breaker with 277V AC voltage rating and 2.2s trip delay. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 5000A. Ideal for panel mounting applications in series trip circuits, this toggle actuator breaker operates b/w -40°C to 85°C temperatures.

40 A

5 kA

277 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Toggle

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

CA2-B0-34-615-121-C by Carling Technologies

CA2-B0-34-615-121-C

Carling Technologies

Carling Technologies CA2-B0-34-615-121-C is a 15A circuit breaker with 480V AC voltage rating. Featuring magnetic protection, it has a breaking capacity of 10kA and operates b/w -40°C to 85°C. Ideal for panel mounting in UL-standard applications requiring reliable series trip functionality.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B0-34-615-121-E by Carling Technologies

CA2-B0-34-615-121-E

Carling Technologies

Carling Technologies CA2-B0-34-615-121-E is a 15A magnetic circuit breaker with 480V AC and 150V DC ratings. Featuring a panel mount design, it has a compact body measuring 47x38.48x63.5mm, suitable for series trip applications in various industries.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B0-34-615-121-I by Carling Technologies

CA2-B0-34-615-121-I

Carling Technologies

Carling Technologies CA2-B0-34-615-121-I is a 15A magnetic circuit breaker with 480V AC and 150V DC ratings. Featuring a compact design (47x38.48x63.5 mm), it has a high breaking capacity of 10000A. Ideal for panel mounting in series trip circuits, UL certified for applications requiring reliable overcurrent protection up to 85°C and down to -40°C.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B2-12-610-121-C by Carling Technologies

CA2-B2-12-610-121-C

Carling Technologies

Carling Technologies CA2-B2-12-610-121-C is a 10A circuit breaker with 480V AC and 150V DC ratings. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10000A. Ideal for panel mounting applications in UL standard circuits, with a temperature range from -40°C to 85°C.

10 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B2-46-635-622-E by Carling Technologies

CA2-B2-46-635-622-E

Carling Technologies

Carling Technologies CA2-B2-46-635-622-E is a 35A circuit breaker with 480V AC voltage rating. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10kA. Ideal for panel mounting in applications requiring series trip functionality and UL compliance.

35 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

MF2-B-64-622-2-CC6-B-C by Carling Technologies

MF2-B-64-622-2-CC6-B-C

Carling Technologies

Carling Technologies MF2-B-64-622-2-CC6-B-C is a 22A circuit breaker with 250V AC voltage rating. It features chemical/corrosion/moisture resistance, screw terminals, and an illuminated rocker actuator. Ideal for panel mounting in applications requiring series trip circuit protection up to 1000A breaking capacity.

22 A

1 kA

250 V

1.53 in (38.86 mm)

1.375 in (34.93 mm)

1.304 in (33.12 mm)

Illuminated Rocker

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

UL; CSA

Screw

Panel Mount

AA2-B0-10-625-1B1-C by Carling Technologies

AA2-B0-10-625-1B1-C

Carling Technologies

Carling Technologies AA2-B0-10-625-1B1-C is a 25A magnetic circuit breaker with 7500A rated breaking capacity. Featuring quick connect terminals, it is corrosion/moisture resistant and suitable for panel mounting applications in environments ranging from -40°C to 85°C.

25 A

7.5 kA

80 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

AA2-B0-26-410-1B1-C by Carling Technologies

AA2-B0-26-410-1B1-C

Carling Technologies

Carling Technologies AA2-B0-26-410-1B1-C is a 277V, 1A magnetic circuit breaker with quick connect terminals. It offers corrosion/moisture resistance and operates in temperatures from -40°C to 85°C. Ideal for panel mounting in applications requiring series trip circuit protection up to 5000A.

1 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

AA2-B0-34-625-9G7-C by Carling Technologies

AA2-B0-34-625-9G7-C

Carling Technologies

Carling Technologies AA2-B0-34-625-9G7-C is a 25A magnetic circuit breaker with 277V AC and 80V DC ratings. It features corrosion-resistant design, screw terminals, and panel mount for series trip applications. Operating temperatures range from -40°C to 85°C, meeting CSA and UL standards.

25 A

5 kA

277 V

80 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

AA2-B0-44-630-5B1-C by Carling Technologies

AA2-B0-44-630-5B1-C

Carling Technologies

Carling Technologies AA2-B0-44-630-5B1-C is a 30A magnetic circuit breaker with 277V AC voltage rating. It features corrosion/moisture resistance, screw terminals, and panel mount for series trip applications. Rated at 5000A breaking capacity, it operates b/w -40°C to 85°C as per CSA and UL standards.

30 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

AB2-B0-34-625-5D1-C by Carling Technologies

AB2-B0-34-625-5D1-C

Carling Technologies

Carling Technologies AB2-B0-34-625-5D1-C is a 25A magnetic circuit breaker with 277V AC and 80V DC ratings. It features corrosion/moisture resistance, screw terminals, and a panel mount design. Ideal for series trip applications in environments ranging from -40°C to 85°C.

25 A

5 kA

277 V

80 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

AC2-B0-24-625-431-D by Carling Technologies

AC2-B0-24-625-431-D

Carling Technologies

Carling Technologies AC2-B0-24-625-431-D is a 25A magnetic circuit breaker with 250V rated AC voltage. It features corrosion/moisture resistance, screw terminals, and rocker actuator. Ideal for panel mounting in applications requiring series trip circuit protection with CSA, UL, VDE standards compliance.

25 A

1 kA

250 V

1.64 in (41.66 mm)

2.156 in (54.76 mm)

1.515 in (38.48 mm)

Rocker

Series Trip

2

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Screw

Panel Mount

AC2-B2-26-610-144-C by Carling Technologies

AC2-B2-26-610-144-C

Carling Technologies

Carling Technologies AC2-B2-26-610-144-C is a 10A magnetic circuit breaker with 277V rated AC voltage. Featuring quick connect terminals, it is corrosion/moisture resistant and has a breaking capacity of 5000A. Ideal for panel mounting in applications requiring series trip circuit protection.

10 A

5 kA

277 V

1.64 in (41.66 mm)

2.156 in (54.76 mm)

1.515 in (38.48 mm)

Rocker

Series Trip

2

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

AD2-B0-34-625-3B1-C by Carling Technologies

AD2-B0-34-625-3B1-C

Carling Technologies

Carling Technologies AD2-B0-34-625-3B1-C is a 25A magnetic circuit breaker with 277V AC and 80V DC ratings. Featuring corrosion-resistant design, it has a panel mount for series trip applications. With CSA and UL certifications, it operates b/w -40°C to 85°C temperatures efficiently.

25 A

5 kA

277 V

80 V

1.64 in (41.66 mm)

2.156 in (54.76 mm)

1.515 in (38.48 mm)

Rocker

Series Trip

2

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

AF2-B0-14-620-413-D by Carling Technologies

AF2-B0-14-620-413-D

Carling Technologies

Carling Technologies AF2-B0-14-620-413-D is a 20A magnetic circuit breaker with 3000A breaking capacity. It features corrosion/moisture resistance, screw terminals, and rocker actuator. Ideal for panel mounting in applications requiring series trip circuit protection at temperatures ranging from -40°C to 85°C.

20 A

3 kA

80 V

1.64 in (41.66 mm)

2.156 in (54.76 mm)

1.515 in (38.48 mm)

Rocker

Series Trip

2

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Screw

Panel Mount

AF2-B0-16-610-533-C by Carling Technologies

AF2-B0-16-610-533-C

Carling Technologies

Carling Technologies AF2-B0-16-610-533-C is a 10A magnetic circuit breaker with 7500A breaking capacity. It features corrosion/moisture resistance, screw terminals, and rocker actuator for panel mounting. Ideal for series trip applications in environments ranging from -40°C to 85°C.

10 A

7.5 kA

80 V

1.64 in (41.66 mm)

2.156 in (54.76 mm)

1.515 in (38.48 mm)

Rocker

Series Trip

2

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount