Part RoHS Manufacturer Description Rated Current Rated Breaking Capacity Rated AC Voltage Rated DC Voltage Body Height Body Length/Diameter Body Width Dimensions Actuator Type Blow Characteristic Trip Time/Delay Circuit Function No. of Poles Circuit Protection Type Additional Features Minimum Operating Temperature Maximum Operating Temperature Environmental Characteristics Reference Standard Manufacturer Series Terminal Shape Mounting Feature Packing Method
AF2-B0-44-610-531-C by Carling Technologies

AF2-B0-44-610-531-C

Carling Technologies

Carling Technologies AF2-B0-44-610-531-C is a 10A magnetic circuit breaker with 277V AC voltage rating. Its compact design (54.76mm x 38.48mm x 41.66mm) and corrosion-resistant build make it ideal for panel mounting in various applications requiring series trip circuit protection up to 5000A breaking capacity at temperatures ranging from -40°C to 85°C.

10 A

5 kA

277 V

1.64 in (41.66 mm)

2.156 in (54.76 mm)

1.515 in (38.48 mm)

Rocker

Series Trip

2

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

3120-F323-P7T1-W19FG4-10A by E-t-a Elektrotechnische Apparate

3120-F323-P7T1-W19FG4-10A

E-t-a Elektrotechnische Apparate

3120-F323-P7T1-W19FG4-10A by E-t-a Elektrotechnische Apparate is a 10A thermal circuit breaker with a rated AC voltage of 250V. It features corrosion/moisture resistance, IP40 protection, and trip-free circuit function. Ideal for panel mounting applications in environments with temperatures ranging from -30 to 60°C.

10 A

5 kA

250 V

50 V

1.299 in (33 mm)

2.126 in (54 mm)

0.984 in (25 mm)

Rocker

Trip Free

2

Thermal Circuit Breaker

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion/Moisture Resistant; IP00; IP40

CSA; UL

Tab/Blade

Panel Mount

Bulk

4230-T120-K0DE-5A by E-t-a Elektrotechnische Apparate

4230-T120-K0DE-5A

E-t-a Elektrotechnische Apparate

4230-T120-K0DE-5A by E-t-a Elektrotechnische Apparate is a 5A circuit breaker with rated AC voltage of 480V. It features thermal magnetic protection, DIN rail mounting, and trip-free circuit function. Ideal for applications requiring corrosion resistance and IP20 environmental characteristics.

5 A

5 kA

480 V

125 V

2.37 in (60.2 mm)

3.228 in (82 mm)

1.39 in (35.3 mm)

Toggle Handle

Trip Free

2

Thermal Magnetic Circuit Breaker

-35 °C (-31 °F)

70 °C (158 °F)

Corrosion Resistant; IP20

UL; TUV

Snap On

DIN Rail Mount

CA2-B0-21-620-622-DG by Carling Technologies

CA2-B0-21-620-622-DG

Carling Technologies

CA2-B0-21-620-622-DG by Carling Technologies is a 20A magnetic circuit breaker with a rated AC voltage of 120V. It has a corrosion/moisture resistant body and can operate in temperatures ranging from -40 to 85 °C. This panel mount breaker is commonly used for series trip circuit protection in various applications.

20 A

10 kA

120 V

1.85 in (47 mm)

2.5 in (63.5 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Stud

Panel Mount

CA2-B0-34-615-121-R by Carling Technologies

CA2-B0-34-615-121-R

Carling Technologies

CA2-B0-34-615-121-R by Carling Technologies is a 15A magnetic circuit breaker with 250V AC and 80V DC ratings. With corrosion resistance, it's ideal for panel mounting in applications requiring series trip circuit protection up to 5000A breaking capacity. Operating b/w -40°C to 85°C, it meets CSA, TUV, and UL standards.

15 A

5 kA

250 V

80 V

1.85 in (47 mm)

2.5 in (63.5 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; TUV; UL

Stud

Panel Mount

CX2-B0-14-620-22A-15G by Carling Technologies

CX2-B0-14-620-22A-15G

Carling Technologies

Carling Technologies CX2-B0-14-620-22A-15G is a 20A magnetic circuit breaker with 10000A rated breaking capacity. It features corrosion/moisture resistance, screw terminals, and UL certification. Ideal for panel mounting in applications requiring series trip circuit protection up to 410V DC at temperatures ranging from -40°C to 85°C.

20 A

10 kA

410 V

2.264 in (57.51 mm)

3.672 in (93.26 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

UL

Screw

Panel Mount

BA2-B0-46-625-521-C by Carling Technologies

BA2-B0-46-625-521-C

Carling Technologies

Carling Technologies BA2-B0-46-625-521-C is a 25A circuit breaker with 250V AC voltage rating. It features corrosion/moisture resistance, screw terminals, and magnetic protection. Ideal for panel mounting in applications requiring series trip functionality and high breaking capacity up to 5000A.

25 A

5 kA

250 V

1.73 in (43.94 mm)

2 in (50.8 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

BA2-B2-36-625-525-C by Carling Technologies

BA2-B2-36-625-525-C

Carling Technologies

Carling Technologies BA2-B2-36-625-525-C is a 25A magnetic circuit breaker with 250V AC and 80V DC ratings. It features corrosion/moisture resistance, screw terminals, and a handle actuator. Ideal for panel mounting in applications requiring series trip circuit protection up to 5000A breaking capacity.

25 A

5 kA

250 V

80 V

1.73 in (43.94 mm)

2 in (50.8 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

AM2-B0-14-610-201-C by Carling Technologies

AM2-B0-14-610-201-C

Carling Technologies

Carling Technologies AM2-B0-14-610-201-C is a 10A magnetic circuit breaker with 7500A rated breaking capacity. Featuring screw terminals and toggle actuator, it is corrosion/moisture resistant and operates b/w -40 to 85°C. Ideal for panel mounting in applications requiring series trip circuit protection at up to 80V DC.

10 A

7.5 kA

80 V

1.817 in (46.15 mm)

2 in (50.8 mm)

1.49 in (37.85 mm)

Toggle

Series Trip

2

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

MS2-B-20-615-1-1CB-A-0DC by Carling Technologies

MS2-B-20-615-1-1CB-A-0DC

Carling Technologies

Carling Technologies MS2-B-20-615-1-1CB-A-0DC is a 240V, 15A circuit breaker with IP68 rating. Featuring sealed toggle actuator and quick connect terminals, it offers series trip circuit function. Ideal for panel mounting applications in environments ranging from -40°C to 85°C.

15 A

2 kA

240 V

2.158 in (54.81 mm)

1.375 in (34.93 mm)

1.3 in (33.02 mm)

Sealed Toggle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Moisture Resistant; IP68;

CUL; UL

Quick Connect

Panel Mount

MS2-M-24-620-2-1CA-A-0CA by Carling Technologies

MS2-M-24-620-2-1CA-A-0CA

Carling Technologies

Carling Technologies MS2-M-24-620-2-1CA-A-0CA is a 20A circuit breaker with IP68 rating, suitable for applications requiring moisture resistance. With a rated AC voltage of 240V and magnetic protection, it operates in temperatures from -40°C to 85°C. Featuring sealed toggle actuator and panel mount, it's ideal for series trip circuits needing reliable performance.

20 A

2 kA

240 V

2.158 in (54.81 mm)

1.375 in (34.93 mm)

1.3 in (33.02 mm)

Sealed Toggle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Moisture Resistant; IP68;

Screw

Panel Mount

GA2-B3-11-663-12-MC by Carling Technologies

GA2-B3-11-663-12-MC

Carling Technologies

Carling Technologies GA2-B3-11-663-12-MC is a 63A magnetic circuit breaker with 3000A breaking capacity. It features corrosion/moisture resistance, snap-on terminals, and DIN-rail mounting. Ideal for applications requiring series trip circuit protection in environments with temperatures ranging from -40°C to 85°C.

63 A

3 kA

80 V

2.62 in (66.55 mm)

4.188 in (106.38 mm)

1.376 in (34.95 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA, UL

Snap On

DIN Rail Mount

TA45-ABFGP140C0-AZM14 by Schurter Ag

TA45-ABFGP140C0-AZM14

Schurter Ag

Schurter Ag's TA45-ABFGP140C0-AZM14 is a 14A thermal circuit breaker with 240V AC voltage rating. Featuring IP00, IP40, IP54, and IP65 environmental characteristics, it has a rated breaking capacity of 1000A. Ideal for panel mounting applications in various industries due to its compact dimensions and high reliability.

14 A

1 kA

240 V

60 V

1.339 in (34 mm)

1.89 in (48 mm)

0.984 in (25 mm)

Rocker

Trip

2

Thermal Circuit Breaker

-10 °C (14 °F)

55 °C (131 °F)

IP00; IP40; IP54; IP65

CSA; SEMKO; SEV; UL; VDE

Quick Connect

Panel Mount

TA45-ABFXF110C0-AZM13 by Schurter Ag

TA45-ABFXF110C0-AZM13

Schurter Ag

Schurter Ag's TA45-ABFXF110C0-AZM13 is a 11A thermal circuit breaker with 240V AC voltage rating. It features IP00, IP40, IP54, and IP65 environmental characteristics. Ideal for panel mount applications with manual on/off circuit function.

11 A

1 kA

240 V

60 V

1.339 in (34 mm)

1.89 in (48 mm)

0.984 in (25 mm)

Rocker

Manual On/Off

2

Thermal Circuit Breaker

-10 °C (14 °F)

55 °C (131 °F)

IP00; IP40; IP54; IP65

CSA; SEMKO; SEV; UL; VDE

Quick Connect

Panel Mount

3120-N321-P7T1-W01D-10A by E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W01D-10A

E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W01D-10A by E-t-a Elektrotechnische Apparate is a 10A thermal circuit breaker with a rated AC voltage of 240V. It features corrosion-resistant properties, IP40 protection, and quick connect terminals. Ideal for panel mounting applications, this circuit breaker has a trip-free function and a rated breaking capacity of 5000A.

10 A

5 kA

240 V

50 V

1.299 in (33 mm)

2.22 in (56.4 mm)

0.984 in (25 mm)

Rocker

Trip Free

2

Thermal Circuit Breaker

Rated breaking capacity at 50 VDC: 1000 A

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant; IP00; IP40

CCC; CSA; KC; UL; VDE

Quick Connect

Panel Mount

3120-N321-P7T1-W01D-2A by E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W01D-2A

E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W01D-2A by E-t-a Elektrotechnische Apparate is a 2A thermal circuit breaker with a rated AC voltage of 240V. Featuring corrosion resistance and IP40 protection, it has a compact body measuring 56.4mm x 25mm x 33mm. Ideal for panel mounting applications requiring trip-free circuit protection up to 5000A breaking capacity.

2 A

5 kA

240 V

50 V

1.299 in (33 mm)

2.22 in (56.4 mm)

0.984 in (25 mm)

Rocker

Trip Free

2

Thermal Circuit Breaker

Rated breaking capacity at 50 VDC: 1000 A

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant; IP00; IP40

CCC; CSA; KC; UL; VDE

Quick Connect

Panel Mount

3120-N321-P7T1-W01D-3A by E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W01D-3A

E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W01D-3A by E-t-a Elektrotechnische Apparate is a 3A thermal circuit breaker with a rated AC voltage of 240V. It features corrosion-resistant properties, IP40 environmental rating, and quick connect terminals. Ideal for panel mounting applications, this circuit breaker has a trip-free function and meets standards such as CCC, CSA, KC, UL, and VDE.

3 A

5 kA

240 V

50 V

1.299 in (33 mm)

2.22 in (56.4 mm)

0.984 in (25 mm)

Rocker

Trip Free

2

Thermal Circuit Breaker

Rated breaking capacity at 50 VDC: 1000 A

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant; IP00; IP40

CCC; CSA; KC; UL; VDE

Quick Connect

Panel Mount

3120-N321-P7T1-W01D-5A by E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W01D-5A

E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W01D-5A by E-t-a Elektrotechnische Apparate is a 5A thermal circuit breaker with a rated AC voltage of 240V. Featuring a trip-free circuit function, it has a max operating temperature of 60°C and is corrosion-resistant. Ideal for panel mounting applications, this breaker has quick connect terminals and meets CCC, CSA, KC, UL, and VDE standards.

5 A

5 kA

240 V

50 V

1.299 in (33 mm)

2.22 in (56.4 mm)

0.984 in (25 mm)

Rocker

Trip Free

2

Thermal Circuit Breaker

Rated breaking capacity at 50 VDC: 1000 A

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant; IP00; IP40

CCC; CSA; KC; UL; VDE

Quick Connect

Panel Mount

3120-N321-P7T1-W02D-10A by E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W02D-10A

E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W02D-10A by E-t-a Elektrotechnische Apparate is a 10A thermal circuit breaker with a rated AC voltage of 240V. It features a corrosion-resistant body measuring 56.4mm x 25in x 33mm, suitable for panel mounting applications. With a rated breaking capacity of 5000A and trip-free circuit function, it meets standards such as CCC, CSA, KC, UL, and VDE.

10 A

5 kA

240 V

50 V

1.299 in (33 mm)

2.22 in (56.4 mm)

0.984 in (25 mm)

Rocker

Trip Free

2

Thermal Circuit Breaker

Rated breaking capacity at 50 VDC: 1000 A

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant; IP00; IP40

CCC; CSA; KC; UL; VDE

Quick Connect

Panel Mount

3120-N321-P7T1-W02D-15A by E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W02D-15A

E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W02D-15A by E-t-a Elektrotechnische Apparate is a 15A thermal circuit breaker with a rated AC voltage of 240V. It features corrosion-resistant properties, IP40 protection, and quick connect terminals. Ideal for panel mounting applications, it has a compact body size of 56.4mm x 25mm x 33mm and operates within -30°C to 60°C temperature range.

15 A

5 kA

240 V

50 V

1.299 in (33 mm)

2.22 in (56.4 mm)

0.984 in (25 mm)

Rocker

Trip Free

2

Thermal Circuit Breaker

Rated breaking capacity at 50 VDC: 1000 A

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant; IP00; IP40

CCC; CSA; KC; UL; VDE

Quick Connect

Panel Mount

3120-N323-P7T1-W01D-15A by E-t-a Elektrotechnische Apparate

3120-N323-P7T1-W01D-15A

E-t-a Elektrotechnische Apparate

3120-N323-P7T1-W01D-15A by E-t-a Elektrotechnische Apparate is a 15A thermal circuit breaker with a rated AC voltage of 240V. It features a corrosion-resistant body measuring 56.4mm x 25in x 33mm, suitable for panel mounting applications. With a rated breaking capacity of 5000A and trip-free circuit function, it meets standards like CCC, CSA, KC, UL, and VDE.

15 A

5 kA

240 V

50 V

1.299 in (33 mm)

2.22 in (56.4 mm)

0.984 in (25 mm)

Rocker

Trip Free

2

Thermal Circuit Breaker

Rated breaking capacity at 50 VDC: 1000 A

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant; IP00; IP40

CCC; CSA; KC; UL; VDE

Quick Connect

Panel Mount

3VA5120-6ED21-0AA0 by Siemens

3VA5120-6ED21-0AA0

Siemens

Siemens 3VA5120-6ED21-0AA0 is a 20A circuit breaker with rated AC voltage of 600V. With IP40 protection, it has dimensions of 139.7mm x 50.8mm x 76.2mm and operates b/w -25°C to 70°C. Ideal for panel mounting, it offers thermal circuit protection with a breaking capacity of up to 65000A.

20 A

65 kA

600 V

250 V

3 in (76.2 mm)

5.5 in (139.7 mm)

2 in (50.8 mm)

5.5 x 2 x 3 in (139.7 x 50.8 x 76.2 mm)

Toggle

Trip

2

Thermal Circuit Breaker

-25 °C (-13 °F)

70 °C (158 °F)

IP40

Screw

Panel Mount

229-2-1-61-8-8-1-A by Sensata Technologies

229-2-1-61-8-8-1-A

Sensata Technologies

Sensata Technologies' 229-2-1-61-8-8-1-A is a moisture-resistant magnetic circuit breaker with a rated AC voltage of 480V and current of 1A. Featuring a trip-free toggle handle actuator, it has a rated breaking capacity of 5000A and is ideal for panel mounting applications in various industries.

1 A

5 kA

480 V

3.55 in (90.17 mm)

5.125 in (130.18 mm)

2.072 in (52.63 mm)

Toggle Handle

Trip Free

2

Magnetic Circuit Breaker

Moisture Resistant

CSA; CUL; UL

Stud

Panel Mount

229-2-1-61-8-9-50-A by Sensata Technologies

229-2-1-61-8-9-50-A

Sensata Technologies

The Sensata Technologies circuit breaker 229-2-1-61-8-9-50-A is rated for 480V AC and has a current rating of 50A. With a breaking capacity of 5000A, it features a moisture-resistant design suitable for panel mounting applications. This magnetic circuit breaker with toggle handle actuator is trip-free and meets CSA, CUL, and UL standards.

50 A

5 kA

480 V

3.55 in (90.17 mm)

5.125 in (130.18 mm)

2.072 in (52.63 mm)

Toggle Handle

Trip Free

2

Magnetic Circuit Breaker

Moisture Resistant

CSA; CUL; UL

Stud

Panel Mount

279-2-1-52-9-2-90 by Sensata Technologies

279-2-1-52-9-2-90

Sensata Technologies

Sensata Technologies' 279-2-1-52-9-2-90 is a moisture-resistant circuit breaker with quick connect terminals. It has a rated current of 90A, breaking capacity of 5000A, and DC voltage rating of 160V. Ideal for panel mounting applications requiring trip-free operation in environments where moisture resistance is crucial.

90 A

5 kA

160 V

2.61 in (66.29 mm)

5.8 in (147.32 mm)

2.072 in (52.63 mm)

Toggle Handle

Trip Free

2

Magnetic Circuit Breaker

Moisture Resistant

CSA; CUL; UL

Quick Connect

Panel Mount

410202 by Legrand

410202

Legrand

Legrand 410202 is a 25A thermal magnetic circuit breaker with a rated AC voltage of 400V. Featuring a toggle handle actuator and DIN rail mounting, it offers manual on/off circuit function. With a high breaking capacity of 50000A, it is ideal for industrial applications requiring reliable circuit protection.

25 A

50 kA

400 V

3.11 in (79 mm)

4.106 in (104.3 mm)

2.102 in (53.4 mm)

Toggle Handle

Manual On/Off

2

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

70 °C (158 °F)

IEC

Snap On

DIN Rail Mount

Bulk

BB2-B0-26-625-522-D by Carling Technologies

BB2-B0-26-625-522-D

Carling Technologies

Carling Technologies BB2-B0-26-625-522-D is a 25A magnetic circuit breaker with 250V AC voltage rating. It features corrosion/moisture resistance, screw terminals, and panel mount for series trip applications. Compliant with CSA, UL, VDE standards, it operates b/w -40°C to 85°C temperature range.

25 A

3 kA

250 V

1.73 in (43.94 mm)

2 in (50.8 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Screw

Panel Mount

BB2-B2-26-625-522-D by Carling Technologies

BB2-B2-26-625-522-D

Carling Technologies

Carling Technologies BB2-B2-26-625-522-D is a 25A magnetic circuit breaker with 250V AC voltage rating. It features corrosion/moisture resistance, screw terminals, and panel mount for series trip applications. Rated breaking capacity of 3000A, operating temperature range from -40°C to 85°C, and compliance with CSA, UL, VDE standards make it ideal for various electrical protection needs.

25 A

3 kA

250 V

1.73 in (43.94 mm)

2 in (50.8 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Screw

Panel Mount

CF2-B0-26-650-644-D by Carling Technologies

CF2-B0-26-650-644-D

Carling Technologies

Carling Technologies CF2-B0-26-650-644-D is a 50A magnetic circuit breaker with 250V AC voltage rating. Featuring a corrosion-resistant design, it has a rocker actuator and stud terminals. Ideal for panel mounting applications, it offers a rated breaking capacity of 5000A and operates in temperatures ranging from -40°C to 85°C.

50 A

5 kA

250 V

2.16 in (54.86 mm)

2.5 in (63.5 mm)

1.515 in (38.48 mm)

Rocker

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Stud

Panel Mount

PCB-B1-22-650-1AD-E12 by Carling Technologies

PCB-B1-22-650-1AD-E12

Carling Technologies

Carling Technologies PCB-B1-22-650-1AD-E12 is a 240V, 50A circuit breaker with moisture resistance. Featuring a rocker actuator and UL reference standard, it has a rated breaking capacity of 5000A. Ideal for equipment leakage protection in panel-mounted applications at temperatures ranging from -35°C to 66°C.

50 A

5 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

3.015 in (76.58 mm)

Rocker

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

Moisture Resistant

UL

Stud

Panel Mount

PCG-BA-24-616-1DA-E12 by Carling Technologies

PCG-BA-24-616-1DA-E12

Carling Technologies

Carling Technologies' PCG-BA-24-616-1DA-E12 is a 240V, 16A circuit breaker with a rated breaking capacity of 3000A. Featuring a panel mount and handle actuator, it is ideal for equipment leakage protection in various applications. Compliant with CSA and UL standards, it operates b/w -35°C to 66°C temperatures efficiently.

16 A

3 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

CSA; UL

Stud

Panel Mount

PCG-BA-24-625-1GA-E11 by Carling Technologies

PCG-BA-24-625-1GA-E11

Carling Technologies

Carling Technologies PCG-BA-24-625-1GA-E11 is a 25A circuit breaker with 240V AC voltage rating. Featuring moisture-resistant design, it has a breaking capacity of 5000A and operates in temperatures from -35°C to 66°C. Ideal for equipment protection, it has a toggle handle actuator and UL certification for reliability.

25 A

5 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Toggle Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

Moisture Resistant

UL

Stud

Panel Mount

PCG-BA-24-630-11A-E12 by Carling Technologies

PCG-BA-24-630-11A-E12

Carling Technologies

Carling Technologies PCG-BA-24-630-11A-E12 is a 30A circuit breaker with 240V AC voltage rating. It features moisture-resistant design, UL standard compliance, and toggle handle actuator. Ideal for equipment protection in applications requiring series trip circuit function.

30 A

5 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Toggle Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

Moisture Resistant

UL

Stud

Panel Mount

PCG-BA-24-630-1AA-E12 by Carling Technologies

PCG-BA-24-630-1AA-E12

Carling Technologies

Carling Technologies PCG-BA-24-630-1AA-E12 is a 30A circuit breaker with 240V AC voltage rating. Featuring a body size of 96.52mm x 57.53mm x 75.57mm, it has a breaking capacity of 3000A and operates b/w -35°C to +66°C. Ideal for equipment protection in various applications, it is CSA and UL certified for quality assurance.

30 A

3 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

CSA; UL

Stud

Panel Mount

PCG-BA-24-650-1GA-E11 by Carling Technologies

PCG-BA-24-650-1GA-E11

Carling Technologies

Carling Technologies' PCG-BA-24-650-1GA-E11 is a 240V, 50A circuit breaker with moisture resistance. Featuring a toggle handle actuator and panel mount, it has a rated breaking capacity of 5000A. Ideal for equipment protection in various applications requiring UL standard compliance.

50 A

5 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Toggle Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

Moisture Resistant

UL

Stud

Panel Mount

PCG-BA-24-650-1GB-E11 by Carling Technologies

PCG-BA-24-650-1GB-E11

Carling Technologies

Carling Technologies PCG-BA-24-650-1GB-E11 is a 240V, 50A circuit breaker with a rated breaking capacity of 3000A. Featuring a panel mount design and handle actuator, it is ideal for equipment leakage protection in various applications. Compliant with CSA and UL standards, it ensures reliable circuit protection in temperatures ranging from -35°C to 66°C.

50 A

3 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

CSA; UL

Stud

Panel Mount

W68-X2Q10-10 by TE Connectivity

W68-X2Q10-10

TE Connectivity

TE Connectivity's W68-X2Q10-10 is a 10A circuit breaker with 277V AC voltage rating and 0.03s trip time. Featuring a magnetic type, it has a rated breaking capacity of 5000A. Ideal for panel mounting applications requiring quick connect terminals and series trip functionality.

10 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.5 in (38.1 mm)

Toggle

30 ms

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Quick Connect

Panel Mount

W92-X112-20 by TE Connectivity

W92-X112-20

TE Connectivity

TE Connectivity's W92-X112-20 is a 20A circuit breaker with 277V AC voltage rating and 2.2s trip delay. Featuring a magnetic protection type, it has a rated breaking capacity of 5000A. Ideal for panel mounting applications in series trip circuits, it operates b/w -40°C to 85°C temperature range.

20 A

5 kA

277 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Toggle

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

W92-X112-25 by TE Connectivity

W92-X112-25

TE Connectivity

TE Connectivity's W92-X112-25 is a 25A circuit breaker with 277V AC voltage rating and 2.2s trip time. Featuring a magnetic protection type, it has dimensions of 63.5mm x 38.1mm x 50.82mm and is ideal for panel mounting in series trip applications.

25 A

5 kA

277 V

2.001 in (50.82 mm)

2.5 in (63.5 mm)

1.5 in (38.1 mm)

2.5 x 1.5 x 2.001 in (63.5 x 38.1 x 50.82 mm)

Toggle

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

W92-X112-3 by TE Connectivity

W92-X112-3

TE Connectivity

TE Connectivity's W92-X112-3 is a 3A circuit breaker with 277V AC voltage rating and 2.2s trip time. Featuring toggle actuator, it has a magnetic protection type for series trip applications. With a compact body of 63.5x38.1x46.86 mm, it operates b/w -40°C to 85°C temperature range and offers a breaking capacity of 5000A for panel mounting setups.

3 A

5 kA

277 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Toggle

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

W33-S4B1Q-5 by TE Connectivity

W33-S4B1Q-5

TE Connectivity

TE Connectivity's W33-S4B1Q-5 is a 5A thermal circuit breaker with 250V AC and 50V DC ratings. Featuring a quick connect terminal shape, it has a trip time of 3s and rated breaking capacity of 1000A. Ideal for panel mounting in series trip circuits, this rocker actuator breaker is compact at 48.01mm x 24.89mm x 43.79mm, making it suitable for various applications requiring reliable circuit protection.

5 A

1 kA

250 V

50 V

1.724 in (43.79 mm)

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Rocker

3 s

Series Trip

2

Thermal Circuit Breaker

Quick Connect

Panel Mount

5SY4210-7 by Siemens

5SY4210-7

Siemens

Siemens 5SY4210-7 is a 10A circuit breaker with rated AC voltage of 400V. It features thermal protection, DIN-rail mounting, and IP20 moisture resistance. Ideal for applications requiring reliable circuit protection in environments with temperatures ranging from -25°C to 55°C.

10 A

5 kA

400 V

2.992 in (76 mm)

3.535 in (89.8 mm)

1.386 in (35.2 mm)

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2

Thermal Circuit Breaker

Environmental Characteristics: Sealed

-25 °C (-13 °F)

55 °C (131 °F)

Environment/Moisture Resistant; IP20

CE; CCC; IMQ; RCM; UL; VDE

Screw And Snap On

DIN Rail Mount

60139 by Schneider Electric Sa

60139

Schneider Electric Sa

Schneider Electric Sa's 60139 circuit breaker has a rated AC voltage of 440V and rated current of 4A. With thermal magnetic protection, it offers a breaking capacity of 6000A. Ideal for DIN-rail mounting, this moisture-resistant device is suitable for applications requiring reliable circuit protection in environments with temperatures ranging from -30°C to 70°C.

4 A

6 kA

440 V

125 V

4.213 in (107 mm)

2.874 in (73 mm)

1.417 in (36 mm)

2.874 x 1.417 x 4.213 in (73 x 36 x 107 mm)

Toggle

Trip

2

Thermal Magnetic Circuit Breaker

Rated breaking capacity at 125 VDC: 10000 A, Environmental Characteristics: IP40

-30 °C (-22 °F)

70 °C (158 °F)

Environment/Moisture Resistant; IP20

CCC; CSA; GB; IEC; UL

Snap On

DIN Rail Mount

5SY4213-8 by Siemens

5SY4213-8

Siemens

Siemens 5SY4213-8 is a 13A circuit breaker with rated AC/DC voltage of 400V, suitable for DIN-rail mounting. It offers thermal protection with a breaking capacity of 5000A and operates in temperatures ranging from -25°C to 55°C. Ideal for various applications requiring reliable circuit protection.

13 A

5 kA

400 V

400 V

2.992 in (76 mm)

3.535 in (89.8 mm)

1.386 in (35.2 mm)

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2

Thermal Circuit Breaker

Interrupting current max(DC): 10000 A

-25 °C (-13 °F)

55 °C (131 °F)

CCC; CE; GOST; IMQ; UL; VDE

Snap On

DIN Rail Mount

5SY4208-8 by Siemens

5SY4208-8

Siemens

Siemens 5SY4208-8 is an 8A thermal circuit breaker with a rated AC voltage of 400V. It features DIN-rail mounting, SNAP ON terminals, and a compact size of 89.8mm x 35.2mm x 76mm. Ideal for circuit protection in various applications due to its high breaking capacity of 5000A and compliance with multiple international standards like CCC, CE, GOST, IMQ, UL, and VDE.

8 A

5 kA

400 V

400 V

2.992 in (76 mm)

3.535 in (89.8 mm)

1.386 in (35.2 mm)

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2

Thermal Circuit Breaker

Interrupting current max(DC): 10000 A

-25 °C (-13 °F)

55 °C (131 °F)

CCC; CE; GOST; IMQ; UL; VDE

Snap On

DIN Rail Mount

102164 by Eaton Corporation

102164

Eaton Corporation

Eaton Corporation's 102164 circuit breaker, rated at 6A and 277V AC, features thermal magnetic protection with a breaking capacity of 15000A. With DIN-rail mounting and IP20/IP40 environmental ratings, it is ideal for industrial applications requiring reliable circuit protection in temperatures ranging from -25°C to 75°C.

6 A

15 kA

277 V

48 V

Trip

2

Thermal Magnetic Circuit Breaker

Rated breaking capacity at 400 VAC

-25 °C (-13 °F)

75 °C (167 °F)

IP20; IP40

CE; CSA; EN; IEC; UL

Snap On

DIN Rail Mount

102167 by Eaton Corporation

102167

Eaton Corporation

The Eaton Corporation 102167 Circuit Breaker is rated for 277V AC voltage and has a thermal magnetic circuit protection type with a rated current of 10A. It operates in temperatures ranging from -25°C to 75°C, making it suitable for various applications requiring DIN-RAIL MOUNT installation and IP20/IP40 environmental characteristics.

10 A

15 kA

277 V

48 V

Trip

2

Thermal Magnetic Circuit Breaker

Rated breaking capacity at 400 VAC

-25 °C (-13 °F)

75 °C (167 °F)

IP20; IP40

CE; CSA; EN; IEC; UL

Snap On

DIN Rail Mount

5SJ4218-7HG41 by Siemens

5SJ4218-7HG41

Siemens

Siemens 5SJ4218-7HG41 is a 15A circuit breaker with rated AC voltage of 400V. It offers thermal protection with a breaking capacity of 14000A. Designed for DIN-rail mounting, it is ideal for applications requiring trip circuit function and environmental resistance (IP20/IP40).

15 A

14 kA

400 V

3.031 in (77 mm)

4.283 in (108.8 mm)

1.386 in (35.2 mm)

4.283 x 1.386 x 3.031 in (108.8 x 35.2 x 77 mm)

Trip

2

Thermal Circuit Breaker

Environmental Characteristics: Sealed

-25 °C (-13 °F)

55 °C (131 °F)

Environment Resistant; IP20; IP40

CCC; CE; UL; VDE

Snap On

DIN Rail Mount