Loading...
Part# Info Electrical Specifications Physical Dimensions Fuse Characteristics Operational Environment Design and Compliance Mounting and Packing
Part RoHS Manufacturer Description Rated Current Rated Breaking Capacity Rated AC Voltage Rated DC Voltage Body Height Body Length/Diameter Body Width Dimensions Actuator Type Blow Characteristic Trip Time/Delay Circuit Function No. of Poles Circuit Protection Type Additional Features Minimum Operating Temperature Maximum Operating Temperature Environmental Characteristics Reference Standard Manufacturer Series JESD-609 Code Terminal Shape Terminal Finish Mounting Feature Packing Method
3120-F323-P7T1-W19FG4-10A by E-t-a Elektrotechnische Apparate

3120-F323-P7T1-W19FG4-10A

E-t-a Elektrotechnische Apparate

3120-F323-P7T1-W19FG4-10A by E-t-a Elektrotechnische Apparate is a 10A thermal circuit breaker with a rated AC voltage of 250V. It features corrosion/moisture resistance, IP40 protection, and trip-free circuit function. Ideal for panel mounting applications in environments with temperatures ranging from -30 to 60°C.

10 A

5 kA

250 V

50 V

1.299 in (33 mm)

2.126 in (54 mm)

0.984 in (25 mm)

Rocker

Trip Free

2

Thermal Circuit Breaker

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion/Moisture Resistant; IP00; IP40

CSA; UL

Tab/Blade

Panel Mount

Bulk

1658-G21-02-P10-10A by E-t-a Elektrotechnische Apparate

1658-G21-02-P10-10A

E-t-a Elektrotechnische Apparate

1658-G21-02-P10-10A by E-t-a Elektrotechnische Apparate is a 240V thermal circuit breaker with a rated current of 10A. Featuring a compact body size of 32x14x39.7 mm, it has a manual reset actuator and trip-free function. Ideal for inline mounting applications, it offers high breaking capacity up to 200A and operates within -20 to 60°C temperature range.

10 A

200 A

240 V

28 V

1.563 in (39.7 mm)

1.26 in (32 mm)

0.551 in (14 mm)

Manual Reset

Trip Free

1

Thermal Circuit Breaker

-20 °C (-4 °F)

60 °C (140 °F)

CSA; CUL; UL; VDE

Tab/Blade

Inline/Holder

1658-G21-02-P10-20A by E-t-a Elektrotechnische Apparate

1658-G21-02-P10-20A

E-t-a Elektrotechnische Apparate

1658-G21-02-P10-20A by E-t-a Elektrotechnische Apparate is a 240V thermal circuit breaker with a rated current of 20A. Featuring a manual reset actuator and trip-free circuit function, it has a rated breaking capacity of 200A. Ideal for inline mounting applications, it meets CSA, CUL, UL, and VDE standards.

20 A

200 A

240 V

28 V

1.563 in (39.7 mm)

1.26 in (32 mm)

0.551 in (14 mm)

Manual Reset

Trip Free

1

Thermal Circuit Breaker

-20 °C (-4 °F)

60 °C (140 °F)

CSA; CUL; UL; VDE

Tab/Blade

Inline/Holder

1610-21-6A by E-t-a Elektrotechnische Apparate

1610-21-6A

E-t-a Elektrotechnische Apparate

THERMAL CIRCUIT BREAKER; Mounting Feature: INLINE/HOLDER; Rated DC Voltage: 32 V; Rated Current: 6 A; Terminal Shape: TAB/BLADE; Circuit Function: TRIP FREE;

6 A

150 A

32 V

0.945 in (24 mm)

0.787 in (20 mm)

0.236 in (6 mm)

Push To Reset

Trip Free

1

Thermal Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion Resistant; IP00; IP30; IP54

UL

Tab/Blade

Inline/Holder