Loading...
Part# Info Electrical Specifications Physical Dimensions Fuse Characteristics Operational Environment Design and Compliance Mounting and Packing
Part RoHS Manufacturer Description Rated Current Rated Breaking Capacity Rated AC Voltage Rated DC Voltage Body Height Body Length/Diameter Body Width Dimensions Actuator Type Blow Characteristic Trip Time/Delay Circuit Function No. of Poles Circuit Protection Type Additional Features Minimum Operating Temperature Maximum Operating Temperature Environmental Characteristics Reference Standard Manufacturer Series JESD-609 Code Terminal Shape Terminal Finish Mounting Feature Packing Method
W91-X112-30 by TE Connectivity

W91-X112-30

TE Connectivity

TE Connectivity's W91-X112-30 is a 30A circuit breaker with 277V AC voltage rating and 2.2s trip delay. Featuring toggle actuator, it has magnetic protection with 5000A breaking capacity. Ideal for panel mounting in series trip circuits, operating b/w -40°C to 85°C temperature range.

30 A

5 kA

277 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Toggle

2.2 s

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

W92-X112-30 by TE Connectivity

W92-X112-30

TE Connectivity

TE Connectivity's W92-X112-30 is a 30A circuit breaker with rated AC voltage of 277V. Featuring a trip time of 2.2s, it offers moisture resistance and operates in temperatures from -40°C to 85°C. Ideal for panel mounting, this magnetic breaker has a breaking capacity of 5000A and is suitable for series trip applications.

30 A

5 kA

277 V

1.985 in (50.42 mm)

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Toggle

Standard

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Moisture Resistant

CSA; UL; VDE

Stud

Panel Mount

W92-X112-40 by TE Connectivity

W92-X112-40

TE Connectivity

TE Connectivity's W92-X112-40 is a 40A circuit breaker with 277V AC voltage rating and 2.2s trip delay. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 5000A. Ideal for panel mounting applications in series trip circuits, this toggle actuator breaker operates b/w -40°C to 85°C temperatures.

40 A

5 kA

277 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Toggle

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

W93-X112-40V by TE Connectivity

W93-X112-40V

TE Connectivity

TE Connectivity's W93-X112-40V is a 250V circuit breaker with a trip time of 2.2s. It has a rated current of 40A and can operate in temperatures ranging from -40°C to 85°C. This magnetic circuit breaker, with a rated breaking capacity of 2000A, is suitable for panel mounting and series trip applications.

40 A

2 kA

250 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Toggle

2.2 s

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

CA1-B0-12-225-321-D by Carling Technologies

CA1-B0-12-225-321-D

Carling Technologies

CA1-B0-12-225-321-D by Carling Technologies is a 480V circuit breaker with 0.25A rated current and 10000A breaking capacity. Featuring a handle actuator, it is ideal for panel mounting applications requiring magnetic protection in series trip circuits.

250 mA

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B0-16-625-622-D by Carling Technologies

CA1-B0-16-625-622-D

Carling Technologies

Carling Technologies CA1-B0-16-625-622-D is a 25A magnetic circuit breaker with 480V AC and 150V DC voltage ratings. Featuring a compact design of 47x63.5 mm, it has a breaking capacity of 10kA. Ideal for panel mounting in various applications requiring reliable circuit protection within -40 to 85°C temperature range.

25 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B0-26-210-412-D by Carling Technologies

CA1-B0-26-210-412-D

Carling Technologies

Carling Technologies CA1-B0-26-210-412-D is a 250V magnetic circuit breaker with 0.1A rated current and 5000A breaking capacity. Ideal for panel mounting, it offers corrosion/moisture resistance and operates in temperatures from -40 to 85°C.

100 mA

5 kA

250 V

1.85 in (47 mm)

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Stud

Panel Mount

CA1-B0-32-410-311-C by Carling Technologies

CA1-B0-32-410-311-C

Carling Technologies

Carling Technologies CA1-B0-32-410-311-C is a 1A circuit breaker with 480V AC and 150V DC ratings. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10000A. Ideal for panel mounting applications in various industries due to its UL certification and series trip circuit function.

1 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B0-32-810-AG2-C by Carling Technologies

CA1-B0-32-810-AG2-C

Carling Technologies

Carling Technologies CA1-B0-32-810-AG2-C is a 100A magnetic circuit breaker with 480V AC and 150V DC voltage ratings. Featuring a compact design, it is ideal for panel mounting applications in various industries. With UL certification, this series trip breaker ensures reliable circuit protection from -40°C to 85°C temperatures.

100 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B0-34-450-A21-C by Carling Technologies

CA1-B0-34-450-A21-C

Carling Technologies

CA1-B0-34-450-A21-C by Carling Technologies is a 5A circuit breaker with a rated AC voltage of 480V. Featuring a magnetic circuit protection type, it has a max operating temperature of 85°C and is designed for panel mounting applications. With UL reference standard, this series trip breaker has a rated breaking capacity of 10000A.

5 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B0-46-625-622-C by Carling Technologies

CA1-B0-46-625-622-C

Carling Technologies

CA1-B0-46-625-622-C by Carling Technologies is a 25A magnetic circuit breaker with a rated AC voltage of 480V. Featuring a compact body size of 47x19.05x63.5mm, it has a high breaking capacity of 10kA. Ideal for panel mounting applications in various industries, this UL-certified circuit breaker operates b/w -40°C to 85°C efficiently.

25 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B2-12-610-121-C by Carling Technologies

CA1-B2-12-610-121-C

Carling Technologies

Carling Technologies CA1-B2-12-610-121-C is a 10A magnetic circuit breaker with 480V AC and 150V DC voltage ratings. Featuring a compact design of 47x63.5 mm, it is ideal for panel mounting applications requiring series trip circuit protection up to 10000A breaking capacity.

10 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B2-12-610-121-D by Carling Technologies

CA1-B2-12-610-121-D

Carling Technologies

CA1-B2-12-610-121-D by Carling Technologies is a 10A circuit breaker with 480V AC and 150V DC ratings. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10000A. Ideal for panel mounting applications, it operates in temperatures ranging from -40°C to 85°C.

10 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B2-12-610-121-MG by Carling Technologies

CA1-B2-12-610-121-MG

Carling Technologies

Carling Technologies CA1-B2-12-610-121-MG is a 10A magnetic circuit breaker with 240V AC and 80V DC ratings. Featuring a compact design of 47x19.05x63.5mm, it has a series trip function and UL certification for panel mounting applications in various industries.

10 A

10 kA

240 V

80 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B2-12-620-321-C by Carling Technologies

CA1-B2-12-620-321-C

Carling Technologies

Carling Technologies CA1-B2-12-620-321-C is a 20A magnetic circuit breaker with 480V AC and 150V DC ratings. Featuring a panel mount design, it has a compact body measuring 47x19.05x63.5mm (LxWxH). Ideal for UL-rated applications requiring series trip protection in temperatures ranging from -40°C to 85°C.

20 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B0-34-615-121-C by Carling Technologies

CA2-B0-34-615-121-C

Carling Technologies

Carling Technologies CA2-B0-34-615-121-C is a 15A circuit breaker with 480V AC voltage rating. Featuring magnetic protection, it has a breaking capacity of 10kA and operates b/w -40°C to 85°C. Ideal for panel mounting in UL-standard applications requiring reliable series trip functionality.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B0-34-615-121-E by Carling Technologies

CA2-B0-34-615-121-E

Carling Technologies

Carling Technologies CA2-B0-34-615-121-E is a 15A magnetic circuit breaker with 480V AC and 150V DC ratings. Featuring a panel mount design, it has a compact body measuring 47x38.48x63.5mm, suitable for series trip applications in various industries.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B0-34-615-121-I by Carling Technologies

CA2-B0-34-615-121-I

Carling Technologies

Carling Technologies CA2-B0-34-615-121-I is a 15A magnetic circuit breaker with 480V AC and 150V DC ratings. Featuring a compact design (47x38.48x63.5 mm), it has a high breaking capacity of 10000A. Ideal for panel mounting in series trip circuits, UL certified for applications requiring reliable overcurrent protection up to 85°C and down to -40°C.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B2-12-610-121-C by Carling Technologies

CA2-B2-12-610-121-C

Carling Technologies

Carling Technologies CA2-B2-12-610-121-C is a 10A circuit breaker with 480V AC and 150V DC ratings. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10000A. Ideal for panel mounting applications in UL standard circuits, with a temperature range from -40°C to 85°C.

10 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B2-46-635-622-E by Carling Technologies

CA2-B2-46-635-622-E

Carling Technologies

Carling Technologies CA2-B2-46-635-622-E is a 35A circuit breaker with 480V AC voltage rating. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10kA. Ideal for panel mounting in applications requiring series trip functionality and UL compliance.

35 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA3-B0-22-620-122-D by Carling Technologies

CA3-B0-22-620-122-D

Carling Technologies

Carling Technologies CA3-B0-22-620-122-D is a 20A magnetic circuit breaker with 480V AC and 150V DC ratings. Featuring a panel mount design, it has a compact body measuring 47x57.53x63.5mm, making it ideal for series trip applications in various industries.

20 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

2.265 in (57.53 mm)

Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

C21-B0-20-630-41A-E by Carling Technologies

C21-B0-20-630-41A-E

Carling Technologies

Carling Technologies C21-B0-20-630-41A-E is a 30A magnetic circuit breaker with 7500A breaking capacity. Featuring a corrosion-resistant body, it has a max operating temperature of 85°C and min of -40°C. Ideal for panel mounting applications, it is designed with a rocker actuator and stud terminals.

30 A

7.5 kA

80 V

1.85 in (47 mm)

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Rocker

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; TUV; UL

Stud

Panel Mount

CA1-B2-16-435-1B1-C by Carling Technologies

CA1-B2-16-435-1B1-C

Carling Technologies

Carling Technologies CA1-B2-16-435-1B1-C is a 3.5A magnetic circuit breaker with 7500A rated breaking capacity. It features corrosion/moisture resistance, stud terminal shape, and panel mount for series trip applications. Rated for -40 to 85°C, suitable for CSA/UL standards in various electrical systems.

3.5 A

7.5 kA

80 V

1.85 in (47 mm)

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Stud

Panel Mount

CA1-B2-16-435-AB1-C by Carling Technologies

CA1-B2-16-435-AB1-C

Carling Technologies

Carling Technologies CA1-B2-16-435-AB1-C is a 3.5A magnetic circuit breaker with 7500A rated breaking capacity. It is corrosion/moisture resistant, UL/CSA certified, and has a handle actuator for panel mounting applications. Operating temperature range: -40 to 85°C.

3.5 A

7.5 kA

80 V

1.85 in (47 mm)

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Stud

Panel Mount

CA2-B0-21-620-622-DG by Carling Technologies

CA2-B0-21-620-622-DG

Carling Technologies

CA2-B0-21-620-622-DG by Carling Technologies is a 20A magnetic circuit breaker with a rated AC voltage of 120V. It has a corrosion/moisture resistant body and can operate in temperatures ranging from -40 to 85 °C. This panel mount breaker is commonly used for series trip circuit protection in various applications.

20 A

10 kA

120 V

1.85 in (47 mm)

2.5 in (63.5 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Stud

Panel Mount

CA2-B0-34-615-121-R by Carling Technologies

CA2-B0-34-615-121-R

Carling Technologies

CA2-B0-34-615-121-R by Carling Technologies is a 15A magnetic circuit breaker with 250V AC and 80V DC ratings. With corrosion resistance, it's ideal for panel mounting in applications requiring series trip circuit protection up to 5000A breaking capacity. Operating b/w -40°C to 85°C, it meets CSA, TUV, and UL standards.

15 A

5 kA

250 V

80 V

1.85 in (47 mm)

2.5 in (63.5 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; TUV; UL

Stud

Panel Mount

CM3-A0-03-670-301-C by Carling Technologies

CM3-A0-03-670-301-C

Carling Technologies

Carling Technologies CM3-A0-03-670-301-C is a 70A magnetic circuit breaker with 250V AC voltage rating. Featuring a toggle handle actuator and stud terminal shape, it is corrosion/moisture resistant for panel mount applications. Compliant with CSA and UL standards, it operates b/w -40°C to 85°C efficiently.

70 A

250 V

1.85 in (47 mm)

2.5 in (63.5 mm)

2.24 in (56.9 mm)

Toggle Handle

Switch

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA, UL

Stud

Panel Mount

CS1-B2-12-610-121-MG by Carling Technologies

CS1-B2-12-610-121-MG

Carling Technologies

CS1-B2-12-610-121-MG by Carling Technologies is a 10A magnetic circuit breaker with 5000A breaking capacity. It features corrosion/moisture resistance and operates b/w -40 to 85°C. Ideal for panel mounting in applications requiring reliable series trip circuit protection.

10 A

5 kA

125 V

1.85 in (47 mm)

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Stud

Panel Mount

209-1-1-62-4-9-10 by Sensata Technologies

209-1-1-62-4-9-10

Sensata Technologies

Sensata Technologies' 209-1-1-62-4-9-10 is a 240V magnetic circuit breaker with 10A rated current and 5000A breaking capacity. It features moisture-resistant design, toggle actuator, and panel mount for trip-free circuit protection applications. Compliant with CSA, CUL, and UL standards.

10 A

5 kA

240 V

3.55 in (90.17 mm)

5.125 in (130.18 mm)

1.026 in (26.06 mm)

Toggle

Trip Free

1

Magnetic Circuit Breaker

Moisture Resistant

CSA; CUL; UL

Stud

Panel Mount

209-1-1-62-4-9-15-V by Sensata Technologies

209-1-1-62-4-9-15-V

Sensata Technologies

Sensata Technologies' 209-1-1-62-4-9-15-V is a moisture-resistant circuit breaker with rated AC voltage of 240V and current of 15A. Featuring a magnetic trip-free circuit protection type, it has a breaking capacity of 5000A. Ideal for panel mounting applications, this toggle actuator breaker meets CSA, CUL, UL, and VDE standards.

15 A

5 kA

240 V

3.55 in (90.17 mm)

5.125 in (130.18 mm)

1.026 in (26.06 mm)

Toggle

Trip Free

1

Magnetic Circuit Breaker

Moisture Resistant

CSA; CUL; UL; VDE

Stud

Panel Mount

229-2-1-61-8-8-1-A by Sensata Technologies

229-2-1-61-8-8-1-A

Sensata Technologies

Sensata Technologies' 229-2-1-61-8-8-1-A is a moisture-resistant magnetic circuit breaker with a rated AC voltage of 480V and current of 1A. Featuring a trip-free toggle handle actuator, it has a rated breaking capacity of 5000A and is ideal for panel mounting applications in various industries.

1 A

5 kA

480 V

3.55 in (90.17 mm)

5.125 in (130.18 mm)

2.072 in (52.63 mm)

Toggle Handle

Trip Free

2

Magnetic Circuit Breaker

Moisture Resistant

CSA; CUL; UL

Stud

Panel Mount

229-2-1-61-8-9-50-A by Sensata Technologies

229-2-1-61-8-9-50-A

Sensata Technologies

The Sensata Technologies circuit breaker 229-2-1-61-8-9-50-A is rated for 480V AC and has a current rating of 50A. With a breaking capacity of 5000A, it features a moisture-resistant design suitable for panel mounting applications. This magnetic circuit breaker with toggle handle actuator is trip-free and meets CSA, CUL, and UL standards.

50 A

5 kA

480 V

3.55 in (90.17 mm)

5.125 in (130.18 mm)

2.072 in (52.63 mm)

Toggle Handle

Trip Free

2

Magnetic Circuit Breaker

Moisture Resistant

CSA; CUL; UL

Stud

Panel Mount

CF2-B0-26-650-644-D by Carling Technologies

CF2-B0-26-650-644-D

Carling Technologies

Carling Technologies CF2-B0-26-650-644-D is a 50A magnetic circuit breaker with 250V AC voltage rating. Featuring a corrosion-resistant design, it has a rocker actuator and stud terminals. Ideal for panel mounting applications, it offers a rated breaking capacity of 5000A and operates in temperatures ranging from -40°C to 85°C.

50 A

5 kA

250 V

2.16 in (54.86 mm)

2.5 in (63.5 mm)

1.515 in (38.48 mm)

Rocker

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Stud

Panel Mount

CT1-B2-12-610-121-MG by Carling Technologies

CT1-B2-12-610-121-MG

Carling Technologies

Carling Technologies CT1-B2-12-610-121-MG is a 10A magnetic circuit breaker with 10000A rated breaking capacity. It features corrosion/moisture resistance, stud terminal shape, and panel mount for series trip applications. Operating temperature ranges from -40°C to 85°C, suitable for various industries per CSA and UL standards.

10 A

10 kA

80 V

1.85 in (47 mm)

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Stud

Panel Mount

EA1-B0-14-670-22B-BC by Carling Technologies

EA1-B0-14-670-22B-BC

Carling Technologies

Carling Technologies EA1-B0-14-670-22B-BC is a 70A magnetic circuit breaker with 5000A breaking capacity. It features corrosion/moisture resistance, stud terminals, and operates b/w -40 to 85°C. Ideal for panel mounting in applications requiring reliable series trip protection at 125V DC.

70 A

5 kA

125 V

2.61 in (66.3 mm)

5.78 in (146.81 mm)

1.026 in (26.06 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Stud

Panel Mount

PCB-B1-22-650-1AD-E12 by Carling Technologies

PCB-B1-22-650-1AD-E12

Carling Technologies

Carling Technologies PCB-B1-22-650-1AD-E12 is a 240V, 50A circuit breaker with moisture resistance. Featuring a rocker actuator and UL reference standard, it has a rated breaking capacity of 5000A. Ideal for equipment leakage protection in panel-mounted applications at temperatures ranging from -35°C to 66°C.

50 A

5 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

3.015 in (76.58 mm)

Rocker

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

Moisture Resistant

UL

Stud

Panel Mount

PCG-BA-24-616-1DA-E12 by Carling Technologies

PCG-BA-24-616-1DA-E12

Carling Technologies

Carling Technologies' PCG-BA-24-616-1DA-E12 is a 240V, 16A circuit breaker with a rated breaking capacity of 3000A. Featuring a panel mount and handle actuator, it is ideal for equipment leakage protection in various applications. Compliant with CSA and UL standards, it operates b/w -35°C to 66°C temperatures efficiently.

16 A

3 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

CSA; UL

Stud

Panel Mount

PCG-BA-24-625-1GA-E11 by Carling Technologies

PCG-BA-24-625-1GA-E11

Carling Technologies

Carling Technologies PCG-BA-24-625-1GA-E11 is a 25A circuit breaker with 240V AC voltage rating. Featuring moisture-resistant design, it has a breaking capacity of 5000A and operates in temperatures from -35°C to 66°C. Ideal for equipment protection, it has a toggle handle actuator and UL certification for reliability.

25 A

5 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Toggle Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

Moisture Resistant

UL

Stud

Panel Mount

PCG-BA-24-630-11A-E12 by Carling Technologies

PCG-BA-24-630-11A-E12

Carling Technologies

Carling Technologies PCG-BA-24-630-11A-E12 is a 30A circuit breaker with 240V AC voltage rating. It features moisture-resistant design, UL standard compliance, and toggle handle actuator. Ideal for equipment protection in applications requiring series trip circuit function.

30 A

5 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Toggle Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

Moisture Resistant

UL

Stud

Panel Mount

PCG-BA-24-630-1AA-E12 by Carling Technologies

PCG-BA-24-630-1AA-E12

Carling Technologies

Carling Technologies PCG-BA-24-630-1AA-E12 is a 30A circuit breaker with 240V AC voltage rating. Featuring a body size of 96.52mm x 57.53mm x 75.57mm, it has a breaking capacity of 3000A and operates b/w -35°C to +66°C. Ideal for equipment protection in various applications, it is CSA and UL certified for quality assurance.

30 A

3 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

CSA; UL

Stud

Panel Mount

PCG-BA-24-650-1GA-E11 by Carling Technologies

PCG-BA-24-650-1GA-E11

Carling Technologies

Carling Technologies' PCG-BA-24-650-1GA-E11 is a 240V, 50A circuit breaker with moisture resistance. Featuring a toggle handle actuator and panel mount, it has a rated breaking capacity of 5000A. Ideal for equipment protection in various applications requiring UL standard compliance.

50 A

5 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Toggle Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

Moisture Resistant

UL

Stud

Panel Mount

PCG-BA-24-650-1GB-E11 by Carling Technologies

PCG-BA-24-650-1GB-E11

Carling Technologies

Carling Technologies PCG-BA-24-650-1GB-E11 is a 240V, 50A circuit breaker with a rated breaking capacity of 3000A. Featuring a panel mount design and handle actuator, it is ideal for equipment leakage protection in various applications. Compliant with CSA and UL standards, it ensures reliable circuit protection in temperatures ranging from -35°C to 66°C.

50 A

3 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

CSA; UL

Stud

Panel Mount

W91-X113-15 by TE Connectivity

W91-X113-15

TE Connectivity

TE Connectivity's W91-X113-15 is a 15A circuit breaker with 277V AC voltage rating and 0.15s trip time. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 5000A. Ideal for panel mounting in applications requiring series trip circuit function.

15 A

5 kA

277 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Toggle

150 ms

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

W92-X112-20 by TE Connectivity

W92-X112-20

TE Connectivity

TE Connectivity's W92-X112-20 is a 20A circuit breaker with 277V AC voltage rating and 2.2s trip delay. Featuring a magnetic protection type, it has a rated breaking capacity of 5000A. Ideal for panel mounting applications in series trip circuits, it operates b/w -40°C to 85°C temperature range.

20 A

5 kA

277 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Toggle

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

W92-X112-25 by TE Connectivity

W92-X112-25

TE Connectivity

TE Connectivity's W92-X112-25 is a 25A circuit breaker with 277V AC voltage rating and 2.2s trip time. Featuring a magnetic protection type, it has dimensions of 63.5mm x 38.1mm x 50.82mm and is ideal for panel mounting in series trip applications.

25 A

5 kA

277 V

2.001 in (50.82 mm)

2.5 in (63.5 mm)

1.5 in (38.1 mm)

2.5 x 1.5 x 2.001 in (63.5 x 38.1 x 50.82 mm)

Toggle

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

W92-X112-3 by TE Connectivity

W92-X112-3

TE Connectivity

TE Connectivity's W92-X112-3 is a 3A circuit breaker with 277V AC voltage rating and 2.2s trip time. Featuring toggle actuator, it has a magnetic protection type for series trip applications. With a compact body of 63.5x38.1x46.86 mm, it operates b/w -40°C to 85°C temperature range and offers a breaking capacity of 5000A for panel mounting setups.

3 A

5 kA

277 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Toggle

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

W93-X112-15 by TE Connectivity

W93-X112-15

TE Connectivity

TE Connectivity's W93-X112-15 is a 15A circuit breaker with 277V AC voltage rating and 2.2s trip delay. Ideal for panel mounting, it features a magnetic protection type and toggle actuator, making it suitable for series trip applications in various industries.

15 A

5 kA

277 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

2.25 in (57.15 mm)

Toggle

2.2 s

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

W93-X112-40 by TE Connectivity

W93-X112-40

TE Connectivity

TE Connectivity's W93-X112-40 is a 40A circuit breaker with 277V AC voltage rating and 2.2s trip delay. Featuring toggle actuator, it has magnetic protection with 5000A breaking capacity. Ideal for panel mounting in series trip circuits, it operates b/w -40°C to 85°C temperature range.

40 A

5 kA

277 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

2.25 in (57.15 mm)

Toggle

2.2 s

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount