Loading...
Part# Info Electrical Specifications Physical Dimensions Fuse Characteristics Operational Environment Design and Compliance Mounting and Packing
Part RoHS Manufacturer Description Rated Current Rated Breaking Capacity Rated AC Voltage Rated DC Voltage Body Height Body Length/Diameter Body Width Dimensions Actuator Type Blow Characteristic Trip Time/Delay Circuit Function No. of Poles Circuit Protection Type Additional Features Minimum Operating Temperature Maximum Operating Temperature Environmental Characteristics Reference Standard Manufacturer Series JESD-609 Code Terminal Shape Terminal Finish Mounting Feature Packing Method
CCB25 by Littelfuse

CCB25

Littelfuse

CCB25 by Littelfuse is a 25A thermal circuit breaker with automatic reset, designed for panel mount applications at 12V DC. It features quick connect terminals and meets SAE standards, making it ideal for automotive and marine electrical systems.

25 A

12 V

Automatic Reset

Thermal Circuit Breaker

SAE

Quick Connect

Panel Mount

W68-X2Q12-15 by TE Connectivity

W68-X2Q12-15

TE Connectivity

TE Connectivity's W68-X2Q12-15 is a 15A magnetic circuit breaker with 277V AC voltage rating and 2.2s trip delay. Featuring quick connect terminals, toggle actuator, and panel mount design, it offers a rated breaking capacity of 5000A. Ideal for series trip applications requiring reliable circuit protection in compact spaces.

15 A

5 kA

277 V

50.8mm X 38.1mm X 51.89mm

Toggle

2.2 s

Series Trip

2

Magnetic Circuit Breaker

Quick Connect

Panel Mount

W68-X2Q12-30 by TE Connectivity

W68-X2Q12-30

TE Connectivity

TE Connectivity's W68-X2Q12-30 is a 30A magnetic circuit breaker with 277V AC voltage rating and 2.2s trip delay. Featuring a toggle actuator and quick connect terminals, it is ideal for panel mounting applications requiring series trip functionality with a rated breaking capacity of 2500A.

30 A

2.5 kA

277 V

Toggle

2.2 s

Series Trip

2

Magnetic Circuit Breaker

Quick Connect

Panel Mount

W33-T2N1Q-20 by TE Connectivity

W33-T2N1Q-20

TE Connectivity

TE Connectivity's W33-T2N1Q-20 is a 20A thermal circuit breaker with a rated AC voltage of 250V. It has a trip time of 3 seconds and a rated breaking capacity of 1000A. This circuit breaker is commonly used for panel mount applications requiring series trip protection.

20 A

1 kA

250 V

50 V

1.724 in (43.79 mm)

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Rocker

3 s

Series Trip

2

Thermal Circuit Breaker

Quick Connect

Panel Mount

W33-T4B1Q-10 by TE Connectivity

W33-T4B1Q-10

TE Connectivity

TE Connectivity's W33-T4B1Q-10 is a 10A thermal circuit breaker with 250V AC and 50V DC ratings. Featuring a quick connect terminal shape, it has a trip time of 3s and rated breaking capacity of 1000A. Ideal for panel mounting in series trip circuits, this rocker actuator device ensures reliable circuit protection.

10 A

1 kA

250 V

50 V

1.724 in (43.79 mm)

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Rocker

3 s

Series Trip

2

Thermal Circuit Breaker

Quick Connect

Panel Mount

W33-T4B1Q-5 by TE Connectivity

W33-T4B1Q-5

TE Connectivity

TE Connectivity's W33-T4B1Q-5 is a 5A thermal circuit breaker with 250V AC and 50V DC ratings. Featuring a quick connect terminal shape, it has a trip time of 3s and breaking capacity of 1000A. Ideal for panel mounting in series trip circuits, this rocker actuator device ensures reliable circuit protection.

5 A

1 kA

250 V

50 V

1.724 in (43.79 mm)

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Rocker

3 s

Series Trip

2

Thermal Circuit Breaker

Quick Connect

Panel Mount

3120-F321-P7T1-W01D-20A by E-t-a Elektrotechnische Apparate

3120-F321-P7T1-W01D-20A

E-t-a Elektrotechnische Apparate

3120-F321-P7T1-W01D-20A by E-t-a Elektrotechnische Apparate is a 20A thermal circuit breaker with a rated AC voltage of 250V. Featuring quick connect terminals and a corrosion-resistant body, it is ideal for panel mounting applications. With a compact size of 54mm x 21mm x 33mm and an operating temperature range from -30°C to 60°C, this rocker actuator circuit breaker meets CCC, CSA, UL, and VDE standards.

20 A

20 A

250 V

50 V

1.299 in (33 mm)

2.126 in (54 mm)

0.827 in (21 mm)

2.126 x 0.827 x 1.299 in (54 x 21 x 33 mm)

Rocker

Manual On/Off

2

Thermal Circuit Breaker

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant

CCC; CSA; UL; VDE

Quick Connect

Panel Mount

3120-F323-P7T1-W01D-5A by E-t-a Elektrotechnische Apparate

3120-F323-P7T1-W01D-5A

E-t-a Elektrotechnische Apparate

3120-F323-P7T1-W01D-5A by E-t-a Elektrotechnische Apparate is a 5A thermal circuit breaker with a rated AC voltage of 250V. Featuring quick connect terminals and a compact size of 54mm x 21mm x 33mm, it is ideal for panel mounting applications. With corrosion-resistant properties and a wide operating temperature range (-30°C to 60°C), this circuit breaker ensures reliable performance in various environments.

5 A

5 A

250 V

50 V

1.299 in (33 mm)

2.126 in (54 mm)

0.827 in (21 mm)

2.126 x 0.827 x 1.299 in (54 x 21 x 33 mm)

Rocker

Manual On/Off

2

Thermal Circuit Breaker

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant

CCC; CSA; UL; VDE

Quick Connect

Panel Mount

3120-F324-P7T1-W01D-10A by E-t-a Elektrotechnische Apparate

3120-F324-P7T1-W01D-10A

E-t-a Elektrotechnische Apparate

3120-F324-P7T1-W01D-10A by E-t-a Elektrotechnische Apparate is a 10A thermal circuit breaker with a rated AC voltage of 250V. Featuring quick connect terminals, it is corrosion resistant and has a max operating temperature of 60°C. Ideal for panel mounting applications, this circuit breaker has a rated breaking capacity of 100A.

10 A

100 A

250 V

50 V

1.299 in (33 mm)

2.205 in (56 mm)

0.827 in (21 mm)

2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm)

Rocker

Manual On/Off

2

Thermal Circuit Breaker

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant

CCC; CSA; UL; VDE

Quick Connect

Panel Mount

3120-F324-P7T1-W01D-6A by E-t-a Elektrotechnische Apparate

3120-F324-P7T1-W01D-6A

E-t-a Elektrotechnische Apparate

3120-F324-P7T1-W01D-6A by E-t-a Elektrotechnische Apparate is a 2-pole circuit breaker with a rated AC voltage of 250V and a rated current of 6A. It has a corrosion-resistant body and quick connect terminals, making it suitable for panel mounting applications.

6 A

6 A

250 V

50 V

1.299 in (33 mm)

2.205 in (56 mm)

0.827 in (21 mm)

2.205 x 0.827 x 1.299 in (56 x 21 x 33 mm)

Rocker

Manual On/Off

2

Thermal Circuit Breaker

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant

CCC; CSA; UL; VDE

Quick Connect

Panel Mount

W68-X2Q12-20 by TE Connectivity

W68-X2Q12-20

TE Connectivity

TE Connectivity's W68-X2Q12-20 is a 20A circuit breaker with rated AC voltage of 277V. Featuring a trip time of 2.2s, it offers standard blow characteristic and magnetic protection. With dimensions of 50.8mm x 38.1mm x 41.66mm, this toggle actuator breaker is ideal for panel mount applications in environments requiring fungus and moisture resistance.

20 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.5 in (38.1 mm)

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W67-X2Q12-10 by TE Connectivity

W67-X2Q12-10

TE Connectivity

TE Connectivity's W67-X2Q12-10 is a 10A circuit breaker with rated AC voltage of 277V and trip time of 2.2s. Its compact dimensions (50.8mm x 19.05mm x 41.66mm) make it ideal for panel mounting applications requiring standard blow characteristic and magnetic protection up to 5000A in series trip circuits.

10 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.75 in (19.05 mm)

2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W67-X2Q12-15 by TE Connectivity

W67-X2Q12-15

TE Connectivity

TE Connectivity's W67-X2Q12-15 is a 15A circuit breaker with rated AC voltage of 277V and trip time of 2.2s. It features quick connect terminals, fungus and moisture resistance, and operates in temperatures from -40°C to 85°C. Ideal for panel mounting applications requiring magnetic circuit protection with CSA and UL standards compliance.

15 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.75 in (19.05 mm)

2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W67-X2Q12-20 by TE Connectivity

W67-X2Q12-20

TE Connectivity

TE Connectivity's W67-X2Q12-20 Circuit Breaker, rated 277V/20A, features a trip time of 2.2s and dimensions of 50.8mm x 19.05mm x 41.66mm. With fungus and moisture resistance, it is ideal for panel mounting in applications requiring magnetic circuit protection with CSA and UL standards compliance.

20 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.75 in (19.05 mm)

2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W67-X2Q12-5 by TE Connectivity

W67-X2Q12-5

TE Connectivity

TE Connectivity's W67-X2Q12-5 is a 5A circuit breaker with a rated AC voltage of 277V and trip time of 2.2s. It features quick connect terminals, fungus and moisture resistance, and operates in temperatures from -40°C to 85°C. Ideal for panel mounting applications requiring magnetic circuit protection with CSA and UL compliance.

5 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.75 in (19.05 mm)

2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W68-X2Q12-3 by TE Connectivity

W68-X2Q12-3

TE Connectivity

TE Connectivity's W68-X2Q12-3 is a 277V circuit breaker with 3A rated current and 2.2s trip time. It features fungus and moisture resistance, toggle actuator, and quick connect terminals. Ideal for panel mounting in applications requiring magnetic circuit protection with CSA and UL standards compliance.

3 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.5 in (38.1 mm)

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W68-X2Q12-5 by TE Connectivity

W68-X2Q12-5

TE Connectivity

TE Connectivity's W68-X2Q12-5 is a 5A circuit breaker with 277V AC voltage rating and 2.2s trip delay. Measuring 50.8mm x 38.1mm x 41.66mm, it offers fungus and moisture resistance for panel mounting applications requiring magnetic circuit protection up to 5000A breaking capacity in temperatures ranging from -40°C to 85°C.

5 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.5 in (38.1 mm)

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W68-X2Q12-7 by TE Connectivity

W68-X2Q12-7

TE Connectivity

TE Connectivity's W68-X2Q12-7 is a 7A circuit breaker with 277V AC voltage rating and 2.2s trip time. Measuring 50.8mm x 38.1mm x 41.66mm, it offers standard blow characteristic and toggle actuator for panel mount applications requiring magnetic circuit protection up to 5000A breaking capacity in harsh environments resistant to fungus and moisture per CSA/UL standards.

7 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.5 in (38.1 mm)

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W69-X2Q12-20 by TE Connectivity

W69-X2Q12-20

TE Connectivity

TE Connectivity's W69-X2Q12-20 is a 20A circuit breaker with rated AC voltage of 277V and trip time of 2.2s. It features fungus and moisture resistance, quick connect terminals, and toggle actuator. Ideal for panel mounting in applications requiring magnetic circuit protection with standard blow characteristic.

20 A

5 kA

277 V

1.64 in (41.66 mm)

2.25 in (57.15 mm)

2 in (50.8 mm)

2.25 x 2 x 1.64 in (57.15 x 50.8 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W69-X2Q12-30 by TE Connectivity

W69-X2Q12-30

TE Connectivity

MAGNETIC CIRCUIT BREAKER; Mounting Feature: PANEL MOUNT; Rated AC Voltage: 277 V; Rated Current: 30 A; Terminal Shape: QUICK CONNECT; Trip Time/Delay: 2.2 Seconds;

30 A

2.5 kA

277 V

1.64 in (41.66 mm)

2.25 in (57.15 mm)

2 in (50.8 mm)

2.25 x 2 x 1.64 in (57.15 x 50.8 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

6-1393250-7 by TE Connectivity

6-1393250-7

TE Connectivity

TE Connectivity 6-1393250-7 is a 20A thermal circuit breaker with 250V AC and 32V DC ratings. Featuring a quick connect terminal shape, it has a trip time of 2.2s and rated breaking capacity of 1000A. Ideal for panel mount applications requiring series trip circuit protection.

20 A

1 kA

250 V

32 V

1.535 in (38.99 mm)

0.76 in (19.31 mm)

0.76 in (19.31 mm)

Push To Reset

2.2 s

Series Trip

1

Thermal Circuit Breaker

Quick Connect

Panel Mount

W28-XT1A-3 by TE Connectivity

W28-XT1A-3

TE Connectivity

TE Connectivity's W28-XT1A-3 is a 3A thermal circuit breaker with a rated AC voltage of 250V and trip time of 2.2s. Featuring push-to-reset actuator, it is ideal for panel mount applications requiring series trip circuit protection in compact spaces.

3 A

250 V

32 V

1.535 in (38.99 mm)

0.76 in (19.31 mm)

0.76 in (19.31 mm)

Push To Reset

2.2 s

Series Trip

1

Thermal Circuit Breaker

Quick Connect

Panel Mount

W33-S1N1Q-10 by TE Connectivity

W33-S1N1Q-10

TE Connectivity

TE Connectivity's W33-S1N1Q-10 is a thermal circuit breaker with a rated AC voltage of 250V and a trip time of 3s. It has a body length of 48.01mm and is commonly used for panel mounting in series trip circuits.

10 A

250 V

50 V

1.724 in (43.79 mm)

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Rocker

3 s

Series Trip

2

Thermal Circuit Breaker

Quick Connect

Panel Mount

W33-S1N1Q-5 by TE Connectivity

W33-S1N1Q-5

TE Connectivity

TE Connectivity's W33-S1N1Q-5 is a 5A thermal circuit breaker with 250V AC and 50V DC ratings. Featuring a quick connect terminal shape, it has a trip time of 3s and a breaking capacity of 1000A. Ideal for panel mounting in series trip circuits.

5 A

1 kA

250 V

50 V

1.724 in (43.79 mm)

1.89 in (48.01 mm)

0.98 in (24.89 mm)

Rocker

3 s

Series Trip

2

Thermal Circuit Breaker

Quick Connect

Panel Mount

1110-F112-P1M1-2A by E-t-a Elektrotechnische Apparate

1110-F112-P1M1-2A

E-t-a Elektrotechnische Apparate

1110-F112-P1M1-2A by E-t-a Elektrotechnische Apparate is a 2A thermal circuit breaker with rated AC voltage of 250V. It features corrosion and moisture resistance, quick connect terminals, and trip-free circuit function. Ideal for panel mounting applications in environments with temperatures ranging from -20°C to 60°C.

2 A

1 kA

250 V

50 V

1.87 in (47.5 mm)

0.748 in (19 mm)

0.52 in (13.2 mm)

0.748 x 0.52 x 1.87 in (19 x 13.2 x 47.5 mm)

Push Button

Medium

Tease-Free And Trip-Free

1

Thermal Circuit Breaker

ENVIRONMENTAL CHARACTERISTICS: IP40; IP00

-20 °C (-4 °F)

60 °C (140 °F)

Corrosion Resistant; Moisture Resistant

CBE; CSA; IEC; UL; VDE

Quick Connect

Panel Mount

1180-01-6A by E-t-a Elektrotechnische Apparate

1180-01-6A

E-t-a Elektrotechnische Apparate

1180-01-6A by E-t-a Elektrotechnische Apparate is a 6A thermal circuit breaker with a rated AC voltage of 250V. Featuring IP40 environmental protection, it has dimensions of 24.4mm x 8.2mm x 48.8mm and operates within temperatures ranging from -20°C to 60°C. Ideal for panel mounting applications requiring trip-free circuit protection.

6 A

2 kA

250 V

72 V

0.961 in (24.4 mm)

1.921 in (48.8 mm)

0.323 in (8.2 mm)

0.961 x 0.323 x 1.921 in (24.4 x 8.2 x 48.8 mm)

Push Button

Trip Free

1

Thermal Circuit Breaker

-20 °C (-4 °F)

60 °C (140 °F)

IP00; IP40

CQC; CSA; EN; IEC; UL; VDE

Quick Connect

Panel Mount

CMB-033-27J6N-B-D/03 by Carling Technologies

CMB-033-27J6N-B-D/03

Carling Technologies

Carling Technologies CMB-033-27J6N-B-D/03 is a 3A thermal circuit breaker with 250V AC and 32V DC ratings. Featuring push-to-reset actuator, it's ideal for panel mount applications requiring manual on/off control. With a compact body size of 29.3x14x45.2 mm, it offers high breaking capacity of 1000A and operates b/w -10°C to 60°C temperatures.

3 A

1 kA

250 V

32 V

1.78 in (45.2 mm)

1.154 in (29.3 mm)

0.551 in (14 mm)

Push To Reset

Manual On/Off

1

Thermal Circuit Breaker

Rated breaking capacity at 32 VDC: 2500 A

-10 °C (14 °F)

60 °C (140 °F)

Quick Connect

Panel Mount

CMB-053-27G3N-B-A by Carling Technologies

CMB-053-27G3N-B-A

Carling Technologies

Carling Technologies CMB-053-27G3N-B-A is a 5A thermal circuit breaker with 250V AC and 32V DC ratings. Featuring push-to-reset actuator, it's ideal for panel mount applications requiring series trip circuit protection. With CSA, CE, CUL, TUV, and UL certifications, it ensures reliable performance in temperatures ranging from -10°C to 60°C.

5 A

1 kA

250 V

32 V

1.78 in (45.2 mm)

1.154 in (29.3 mm)

0.551 in (14 mm)

Push To Reset

Series Trip

1

Thermal Circuit Breaker

-10 °C (14 °F)

60 °C (140 °F)

CSA; CE; CUL; TUV; UL

Quick Connect

Panel Mount

CMB-153-11C3N-B-A/15 by Carling Technologies

CMB-153-11C3N-B-A/15

Carling Technologies

Carling Technologies CMB-153-11C3N-B-A/15 is a 15A thermal circuit breaker with 250V AC and 32V DC ratings. Featuring push-to-reset actuator, it's ideal for panel mount applications requiring manual on/off control. With a compact body size of 29.3x14x45.2 mm, it operates b/w -10°C to 60°C temperature range ensuring reliable circuit protection up to 1000A breaking capacity.

15 A

1 kA

250 V

32 V

1.78 in (45.2 mm)

1.154 in (29.3 mm)

0.551 in (14 mm)

Push To Reset

Manual On/Off

1

Thermal Circuit Breaker

Rated breaking capacity at 32 VDC: 2500 A

-10 °C (14 °F)

60 °C (140 °F)

Quick Connect

Panel Mount

CMB-153-11C3N-B-A by Carling Technologies

CMB-153-11C3N-B-A

Carling Technologies

Carling Technologies CMB-153-11C3N-B-A is a 15A thermal circuit breaker with 250V AC and 32V DC ratings. Featuring push-to-reset actuator, it's panel-mounted for series trip applications. With CSA, CE, CUL, TUV, UL certifications, it operates b/w -10°C to 60°C temperatures effectively.

15 A

1 kA

250 V

32 V

1.78 in (45.2 mm)

1.154 in (29.3 mm)

0.551 in (14 mm)

Push To Reset

Series Trip

1

Thermal Circuit Breaker

-10 °C (14 °F)

60 °C (140 °F)

CSA; CE; CUL; TUV; UL

Quick Connect

Panel Mount

CMB-203-27J8N-B-A/20 by Carling Technologies

CMB-203-27J8N-B-A/20

Carling Technologies

Carling Technologies CMB-203-27J8N-B-A/20 is a 250V thermal circuit breaker with 20A rated current. Featuring push-to-reset actuator, it has a breaking capacity of 1000A and operates b/w -10°C to 60°C. Ideal for panel mounting applications requiring manual on/off circuit protection.

20 A

1 kA

250 V

32 V

1.78 in (45.2 mm)

1.154 in (29.3 mm)

0.551 in (14 mm)

Push To Reset

Manual On/Off

1

Thermal Circuit Breaker

Rated breaking capacity at 32 VDC: 2500 A

-10 °C (14 °F)

60 °C (140 °F)

Quick Connect

Panel Mount

TS-709-5 by Schurter Ag

TS-709-5

Schurter Ag

Schurter Ag's TS-709-5 is a 5A thermal circuit breaker with 125V AC and 32V DC ratings. Featuring a push-to-reset actuator, it has a trip-free circuit function and quick connect terminals. Ideal for panel mounting applications, this UL-approved device offers a high breaking capacity of 1000A.

5 A

1 kA

125 V

32 V

0.886 in (22.5 mm)

1.161 in (29.5 mm)

0.563 in (14.3 mm)

Push To Reset

Trip Free

1

Thermal Circuit Breaker

UL

Quick Connect

Panel Mount

CLB-103-27E3N-W-A/10 by Carling Technologies

CLB-103-27E3N-W-A/10

Carling Technologies

Carling Technologies CLB-103-27E3N-W-A/10 is a 10A thermal circuit breaker with 250V AC and 32V DC ratings. Featuring fire-resistant properties, it has quick connect terminals and push-to-reset actuator for panel mounting applications. With a rated breaking capacity of 300A, it operates b/w -10°C to 60°C, meeting CE, CSA, TUV, and UL standards.

10 A

300 A

250 V

32 V

1.693 in (43 mm)

1.378 in (35 mm)

0.571 in (14.5 mm)

Push To Reset

Series Trip

1

Thermal Circuit Breaker

Rated breaking capacity at 32 VDC: 2500 A

-10 °C (14 °F)

60 °C (140 °F)

Fire Resistant

CE; CSA; TUV; UL

Quick Connect

Panel Mount

AA1-B0-26-430-1B1-C by Carling Technologies

AA1-B0-26-430-1B1-C

Carling Technologies

Carling Technologies AA1-B0-26-430-1B1-C is a 3A magnetic circuit breaker with 277V AC voltage rating. It features corrosion/moisture resistance, quick connect terminals, and a handle actuator. Ideal for panel mounting in applications requiring series trip circuit protection up to 5000A breaking capacity.

3 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

MA1-4-14-610-1-A22-B-M by Carling Technologies

MA1-4-14-610-1-A22-B-M

Carling Technologies

Carling Technologies MA1-4-14-610-1-A22-B-M is a 10A magnetic circuit breaker with 600A rated breaking capacity. It is chemical/corrosion/moisture resistant, UL/CSA certified, and operates b/w -40 to 85°C. Ideal for panel mounting in applications requiring series trip circuit protection.

10 A

600 A

80 V

1.53 in (38.86 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Rocker

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

UL; CSA

Quick Connect

Panel Mount

MD1-B-34-610-1-A42-B-C by Carling Technologies

MD1-B-34-610-1-A42-B-C

Carling Technologies

Carling Technologies MD1-B-34-610-1-A42-B-C is a 10A circuit breaker with 125V AC voltage rating. It features chemical/corrosion/moisture resistance, quick connect terminals, and rocker actuator. Ideal for panel mounting applications requiring magnetic circuit protection with UL/CSA standards compliance.

10 A

1 kA

125 V

80 V

1.53 in (38.86 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Rocker

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

UL; CSA

Quick Connect

Panel Mount

ME1-4-14-610-1-A16-2-T by Carling Technologies

ME1-4-14-610-1-A16-2-T

Carling Technologies

Carling Technologies ME1-4-14-610-1-A16-2-T is a 10A magnetic circuit breaker with 600A rated breaking capacity. It is chemical/corrosion/moisture resistant, UL standard compliant, and has quick connect terminals. Ideal for panel mounting in applications requiring series trip circuit protection at temperatures ranging from -40 to 85°C.

10 A

600 A

80 V

1.53 in (38.86 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Rocker

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

UL

Quick Connect

Panel Mount

MF1-B-32-410-1-CC6-2-D by Carling Technologies

MF1-B-32-410-1-CC6-2-D

Carling Technologies

Carling Technologies' MF1-B-32-410-1-CC6-2-D is a 1A circuit breaker with 250V AC and 80V DC ratings. It features an illuminated rocker actuator, chemical/corrosion/moisture resistance, and quick connect terminals. Ideal for panel mounting in applications requiring series trip circuit protection up to 1000A breaking capacity.

1 A

1 kA

250 V

80 V

1.53 in (38.86 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Illuminated Rocker

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

CSA; UL; VDE

Quick Connect

Panel Mount

MG1-B-32-410-1-CC1-B-C by Carling Technologies

MG1-B-32-410-1-CC1-B-C

Carling Technologies

Carling Technologies' MG1-B-32-410-1-CC1-B-C is a 125V, 1A circuit breaker with chemical/corrosion/moisture resistance. Featuring an illuminated rocker actuator and quick connect terminals, it has a rated breaking capacity of 1000A. Ideal for panel mounting in applications requiring series trip circuit protection.

1 A

1 kA

125 V

80 V

1.53 in (38.86 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Illuminated Rocker

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

UL; CSA

Quick Connect

Panel Mount

MT1-B-32-410-1-C21-B-C by Carling Technologies

MT1-B-32-410-1-C21-B-C

Carling Technologies

Carling Technologies' MT1-B-32-410-1-C21-B-C is a 1A magnetic circuit breaker with 125V AC and 80V DC ratings. It features chemical/corrosion/moisture resistance, quick connect terminals, and push-pull actuator for panel mounting applications. Operating b/w -40°C to 85°C, it offers a high breaking capacity of 1000A in series trip circuits.

1 A

1 kA

125 V

80 V

1.484 in (37.69 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Push-Pull

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

UL; CSA

Quick Connect

Panel Mount

MT1-B-32-410-1-C23-B-C by Carling Technologies

MT1-B-32-410-1-C23-B-C

Carling Technologies

Carling Technologies' MT1-B-32-410-1-C23-B-C is a 125V, 1A circuit breaker with chemical/corrosion/moisture resistance. Featuring quick connect terminals and push-pull actuator, it has a rated breaking capacity of 1000A. Ideal for panel mounting in applications requiring series trip circuit protection.

1 A

1 kA

125 V

80 V

1.484 in (37.69 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Push-Pull

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

UL; CSA

Quick Connect

Panel Mount

MU1-B-32-410-1-C21-B-C by Carling Technologies

MU1-B-32-410-1-C21-B-C

Carling Technologies

Carling Technologies' MU1-B-32-410-1-C21-B-C is a 125V circuit breaker with 1A rated current and 1000A breaking capacity. It is chemical/corrosion/moisture resistant, suitable for panel mounting in applications requiring series trip circuit protection at temperatures ranging from -40°C to 85°C.

1 A

1 kA

125 V

80 V

1.484 in (37.69 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Push To Reset

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

AA1-B0-14-625-1B1-C by Carling Technologies

AA1-B0-14-625-1B1-C

Carling Technologies

Carling Technologies AA1-B0-14-625-1B1-C is a 25A magnetic circuit breaker with 7500A rated breaking capacity. It features corrosion/moisture resistance, quick connect terminals, and operates b/w -40 to 85°C. Ideal for panel mounting in applications requiring reliable series trip circuit protection.

25 A

7.5 kA

80 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

AA1-B0-21-620-1B1-C by Carling Technologies

AA1-B0-21-620-1B1-C

Carling Technologies

Carling Technologies AA1-B0-21-620-1B1-C is a 20A magnetic circuit breaker with 277V AC voltage rating. It features corrosion/moisture resistance, quick connect terminals, and a panel mount for series trip applications. Operating temperature ranges from -40°C to 85°C, meeting CSA and UL standards.

20 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

AA1-B0-21-620-1D2-C by Carling Technologies

AA1-B0-21-620-1D2-C

Carling Technologies

Carling Technologies AA1-B0-21-620-1D2-C is a 20A magnetic circuit breaker with 277V AC voltage rating. It features corrosion/moisture resistance, quick connect terminals, and a handle actuator. Ideal for panel mounting in applications requiring series trip circuit protection up to 5000A breaking capacity.

20 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

AA1-B0-26-450-1D1-C by Carling Technologies

AA1-B0-26-450-1D1-C

Carling Technologies

Carling Technologies AA1-B0-26-450-1D1-C is a 5A magnetic circuit breaker with 277V AC voltage rating. It features corrosion/moisture resistance and quick connect terminals. Ideal for panel mounting in applications requiring series trip circuit protection up to 5000A breaking capacity.

5 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

AA1-B0-26-470-1B1-C by Carling Technologies

AA1-B0-26-470-1B1-C

Carling Technologies

Carling Technologies AA1-B0-26-470-1B1-C is a 7A circuit breaker with 277V AC voltage rating. It features corrosion/moisture resistance, quick connect terminals, and magnetic protection. Ideal for panel mounting in applications requiring series trip circuit function.

7 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

AA2-B0-10-625-1B1-C by Carling Technologies

AA2-B0-10-625-1B1-C

Carling Technologies

Carling Technologies AA2-B0-10-625-1B1-C is a 25A magnetic circuit breaker with 7500A rated breaking capacity. Featuring quick connect terminals, it is corrosion/moisture resistant and suitable for panel mounting applications in environments ranging from -40°C to 85°C.

25 A

7.5 kA

80 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Quick Connect

Panel Mount