Loading...
Part# Info Electrical Specifications Physical Dimensions Fuse Characteristics Operational Environment Design and Compliance Mounting and Packing
Part RoHS Manufacturer Description Rated Current Rated Breaking Capacity Rated AC Voltage Rated DC Voltage Body Height Body Length/Diameter Body Width Dimensions Actuator Type Blow Characteristic Trip Time/Delay Circuit Function No. of Poles Circuit Protection Type Additional Features Minimum Operating Temperature Maximum Operating Temperature Environmental Characteristics Reference Standard Manufacturer Series JESD-609 Code Terminal Shape Terminal Finish Mounting Feature Packing Method
CA1-B0-12-225-321-D by Carling Technologies

CA1-B0-12-225-321-D

Carling Technologies

CA1-B0-12-225-321-D by Carling Technologies is a 480V circuit breaker with 0.25A rated current and 10000A breaking capacity. Featuring a handle actuator, it is ideal for panel mounting applications requiring magnetic protection in series trip circuits.

250 mA

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B0-16-625-622-D by Carling Technologies

CA1-B0-16-625-622-D

Carling Technologies

Carling Technologies CA1-B0-16-625-622-D is a 25A magnetic circuit breaker with 480V AC and 150V DC voltage ratings. Featuring a compact design of 47x63.5 mm, it has a breaking capacity of 10kA. Ideal for panel mounting in various applications requiring reliable circuit protection within -40 to 85°C temperature range.

25 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B0-32-410-311-C by Carling Technologies

CA1-B0-32-410-311-C

Carling Technologies

Carling Technologies CA1-B0-32-410-311-C is a 1A circuit breaker with 480V AC and 150V DC ratings. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10000A. Ideal for panel mounting applications in various industries due to its UL certification and series trip circuit function.

1 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B0-32-810-AG2-C by Carling Technologies

CA1-B0-32-810-AG2-C

Carling Technologies

Carling Technologies CA1-B0-32-810-AG2-C is a 100A magnetic circuit breaker with 480V AC and 150V DC voltage ratings. Featuring a compact design, it is ideal for panel mounting applications in various industries. With UL certification, this series trip breaker ensures reliable circuit protection from -40°C to 85°C temperatures.

100 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B0-34-450-A21-C by Carling Technologies

CA1-B0-34-450-A21-C

Carling Technologies

CA1-B0-34-450-A21-C by Carling Technologies is a 5A circuit breaker with a rated AC voltage of 480V. Featuring a magnetic circuit protection type, it has a max operating temperature of 85°C and is designed for panel mounting applications. With UL reference standard, this series trip breaker has a rated breaking capacity of 10000A.

5 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B0-46-625-622-C by Carling Technologies

CA1-B0-46-625-622-C

Carling Technologies

CA1-B0-46-625-622-C by Carling Technologies is a 25A magnetic circuit breaker with a rated AC voltage of 480V. Featuring a compact body size of 47x19.05x63.5mm, it has a high breaking capacity of 10kA. Ideal for panel mounting applications in various industries, this UL-certified circuit breaker operates b/w -40°C to 85°C efficiently.

25 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B2-12-610-121-C by Carling Technologies

CA1-B2-12-610-121-C

Carling Technologies

Carling Technologies CA1-B2-12-610-121-C is a 10A magnetic circuit breaker with 480V AC and 150V DC voltage ratings. Featuring a compact design of 47x63.5 mm, it is ideal for panel mounting applications requiring series trip circuit protection up to 10000A breaking capacity.

10 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B2-12-610-121-D by Carling Technologies

CA1-B2-12-610-121-D

Carling Technologies

CA1-B2-12-610-121-D by Carling Technologies is a 10A circuit breaker with 480V AC and 150V DC ratings. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10000A. Ideal for panel mounting applications, it operates in temperatures ranging from -40°C to 85°C.

10 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B2-12-620-321-C by Carling Technologies

CA1-B2-12-620-321-C

Carling Technologies

Carling Technologies CA1-B2-12-620-321-C is a 20A magnetic circuit breaker with 480V AC and 150V DC ratings. Featuring a panel mount design, it has a compact body measuring 47x19.05x63.5mm (LxWxH). Ideal for UL-rated applications requiring series trip protection in temperatures ranging from -40°C to 85°C.

20 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA1-B2-34-450-A21-C by Carling Technologies

CA1-B2-34-450-A21-C

Carling Technologies

Carling Technologies CA1-B2-34-450-A21-C is a 5A circuit breaker with 480V AC and 150V DC ratings. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10000A. Ideal for panel mounting applications in various industries due to its compact dimensions and UL certification.

5 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

0.75 in (19.05 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Screw

Panel Mount

CA2-B0-34-615-121-C by Carling Technologies

CA2-B0-34-615-121-C

Carling Technologies

Carling Technologies CA2-B0-34-615-121-C is a 15A circuit breaker with 480V AC voltage rating. Featuring magnetic protection, it has a breaking capacity of 10kA and operates b/w -40°C to 85°C. Ideal for panel mounting in UL-standard applications requiring reliable series trip functionality.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B0-34-615-121-E by Carling Technologies

CA2-B0-34-615-121-E

Carling Technologies

Carling Technologies CA2-B0-34-615-121-E is a 15A magnetic circuit breaker with 480V AC and 150V DC ratings. Featuring a panel mount design, it has a compact body measuring 47x38.48x63.5mm, suitable for series trip applications in various industries.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B0-34-615-121-I by Carling Technologies

CA2-B0-34-615-121-I

Carling Technologies

Carling Technologies CA2-B0-34-615-121-I is a 15A magnetic circuit breaker with 480V AC and 150V DC ratings. Featuring a compact design (47x38.48x63.5 mm), it has a high breaking capacity of 10000A. Ideal for panel mounting in series trip circuits, UL certified for applications requiring reliable overcurrent protection up to 85°C and down to -40°C.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B2-12-610-121-C by Carling Technologies

CA2-B2-12-610-121-C

Carling Technologies

Carling Technologies CA2-B2-12-610-121-C is a 10A circuit breaker with 480V AC and 150V DC ratings. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10000A. Ideal for panel mounting applications in UL standard circuits, with a temperature range from -40°C to 85°C.

10 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B2-46-635-622-E by Carling Technologies

CA2-B2-46-635-622-E

Carling Technologies

Carling Technologies CA2-B2-46-635-622-E is a 35A circuit breaker with 480V AC voltage rating. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10kA. Ideal for panel mounting in applications requiring series trip functionality and UL compliance.

35 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA3-B0-22-620-122-D by Carling Technologies

CA3-B0-22-620-122-D

Carling Technologies

Carling Technologies CA3-B0-22-620-122-D is a 20A magnetic circuit breaker with 480V AC and 150V DC ratings. Featuring a panel mount design, it has a compact body measuring 47x57.53x63.5mm, making it ideal for series trip applications in various industries.

20 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

2.265 in (57.53 mm)

Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B0-34-615-121-D by Carling Technologies

CA2-B0-34-615-121-D

Carling Technologies

Carling Technologies CA2-B0-34-615-121-D is a 15A circuit breaker with 480V AC voltage rating. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10kA. Ideal for panel mounting applications in UL standard compliant setups.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount