Loading...
Part# Info Electrical Specifications Physical Dimensions Fuse Characteristics Operational Environment Design and Compliance Mounting and Packing
Part RoHS Manufacturer Description Rated Current Rated Breaking Capacity Rated AC Voltage Rated DC Voltage Body Height Body Length/Diameter Body Width Dimensions Actuator Type Blow Characteristic Trip Time/Delay Circuit Function No. of Poles Circuit Protection Type Additional Features Minimum Operating Temperature Maximum Operating Temperature Environmental Characteristics Reference Standard Manufacturer Series JESD-609 Code Terminal Shape Terminal Finish Mounting Feature Packing Method
MS1-B-10-430-2-1CB-A-A by Carling Technologies

MS1-B-10-430-2-1CB-A-A

Carling Technologies

Carling Technologies MS1-B-10-430-2-1CB-A-A is a 3A magnetic circuit breaker with IP68 rating. Featuring toggle actuator, it has a rated breaking capacity of 3000A and operates b/w -40°C to 85°C. Ideal for panel mounting in applications requiring reliable circuit protection.

3 A

3 kA

50 V

1.634 in (41.5 mm)

1.375 in (34.93 mm)

0.656 in (16.66 mm)

Toggle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

IP68

Screw

Panel Mount

W68-X2Q12-3 by TE Connectivity

W68-X2Q12-3

TE Connectivity

TE Connectivity's W68-X2Q12-3 is a 277V circuit breaker with 3A rated current and 2.2s trip time. It features fungus and moisture resistance, toggle actuator, and quick connect terminals. Ideal for panel mounting in applications requiring magnetic circuit protection with CSA and UL standards compliance.

3 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

1.5 in (38.1 mm)

2 x 1.5 x 1.64 in (50.8 x 38.1 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

W28-XT1A-3 by TE Connectivity

W28-XT1A-3

TE Connectivity

TE Connectivity's W28-XT1A-3 is a 3A thermal circuit breaker with a rated AC voltage of 250V and trip time of 2.2s. Featuring push-to-reset actuator, it is ideal for panel mount applications requiring series trip circuit protection in compact spaces.

3 A

250 V

32 V

1.535 in (38.99 mm)

0.76 in (19.31 mm)

0.76 in (19.31 mm)

Push To Reset

2.2 s

Series Trip

1

Thermal Circuit Breaker

Quick Connect

Panel Mount

CMB-033-27J6N-B-D/03 by Carling Technologies

CMB-033-27J6N-B-D/03

Carling Technologies

Carling Technologies CMB-033-27J6N-B-D/03 is a 3A thermal circuit breaker with 250V AC and 32V DC ratings. Featuring push-to-reset actuator, it's ideal for panel mount applications requiring manual on/off control. With a compact body size of 29.3x14x45.2 mm, it offers high breaking capacity of 1000A and operates b/w -10°C to 60°C temperatures.

3 A

1 kA

250 V

32 V

1.78 in (45.2 mm)

1.154 in (29.3 mm)

0.551 in (14 mm)

Push To Reset

Manual On/Off

1

Thermal Circuit Breaker

Rated breaking capacity at 32 VDC: 2500 A

-10 °C (14 °F)

60 °C (140 °F)

Quick Connect

Panel Mount

AA1-B0-26-430-1B1-C by Carling Technologies

AA1-B0-26-430-1B1-C

Carling Technologies

Carling Technologies AA1-B0-26-430-1B1-C is a 3A magnetic circuit breaker with 277V AC voltage rating. It features corrosion/moisture resistance, quick connect terminals, and a handle actuator. Ideal for panel mounting in applications requiring series trip circuit protection up to 5000A breaking capacity.

3 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

3120-N321-P7T1-W01D-3A by E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W01D-3A

E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W01D-3A by E-t-a Elektrotechnische Apparate is a 3A thermal circuit breaker with a rated AC voltage of 240V. It features corrosion-resistant properties, IP40 environmental rating, and quick connect terminals. Ideal for panel mounting applications, this circuit breaker has a trip-free function and meets standards such as CCC, CSA, KC, UL, and VDE.

3 A

5 kA

240 V

50 V

1.299 in (33 mm)

2.22 in (56.4 mm)

0.984 in (25 mm)

Rocker

Trip Free

2

Thermal Circuit Breaker

Rated breaking capacity at 50 VDC: 1000 A

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant; IP00; IP40

CCC; CSA; KC; UL; VDE

Quick Connect

Panel Mount

W92-X112-3 by TE Connectivity

W92-X112-3

TE Connectivity

TE Connectivity's W92-X112-3 is a 3A circuit breaker with 277V AC voltage rating and 2.2s trip time. Featuring toggle actuator, it has a magnetic protection type for series trip applications. With a compact body of 63.5x38.1x46.86 mm, it operates b/w -40°C to 85°C temperature range and offers a breaking capacity of 5000A for panel mounting setups.

3 A

5 kA

277 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

1.5 in (38.1 mm)

Toggle

2.2 s

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

5SY4103-8 by Siemens

5SY4103-8

Siemens

Siemens 5SY4103-8 is a 3A circuit breaker with thermal magnetic protection, rated at 277V AC. It features DIN-rail mounting and a handle actuator for easy operation. With a compact size of 90mm x 18mm x 76mm, it is ideal for industrial applications requiring reliable circuit protection.

3 A

5 kA

277 V

2.992 in (76 mm)

3.543 in (90 mm)

0.709 in (18 mm)

3.543 x 0.709 x 2.992 in (90 x 18 x 76 mm)

Handle

Trip

1

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

45 °C (113 °F)

CE; CSA; EN; UL

Snap On

DIN Rail Mount

ESX10-103-DC24V-3A-E by E-t-a Elektrotechnische Apparate

ESX10-103-DC24V-3A-E

E-t-a Elektrotechnische Apparate

ESX10-103-DC24V-3A-E by E-t-a Elektrotechnische Apparate is a 3A circuit breaker with IP30 moisture resistance. It operates at temperatures from 0 to 50 °C and rated for 24V DC voltage. Ideal for equipment protection, it features quick connect terminals and manual on/off actuator for panel mounting applications.

3 A

24 V

2.756 in (70 mm)

2.362 in (60 mm)

0.484 in (12.3 mm)

Manual On/Off

Trip

1

Equipment Leakage Circuit Breaker

0 °C (32 °F)

50 °C (122 °F)

Moisture Resistant; IP00; IP30

CSA; CUL; DNVGL; UL

Quick Connect

Panel Mount

1019974 by Phoenix Contact

1019974

Phoenix Contact

THERMAL MAGNETIC CIRCUIT BREAKER; Mounting Feature: DIN-RAIL MOUNT; Rated AC Voltage: 277 V; Rated DC Voltage: 60 V; Rated Current: 3 A; Terminal Shape: SNAP ON;

3 A

5 kA

277 V

60 V

2.587 in (65.7 mm)

3.205 in (81.4 mm)

0.693 in (17.6 mm)

Toggle

Trip

1

Thermal Magnetic Circuit Breaker

RATED BREAKING CAPACITY AT 60 VDC: 7500 A

-35 °C (-31 °F)

70 °C (158 °F)

IP20

CUL; IEC 60947-2; TUV; UL

Snap On

DIN Rail Mount

Bulk

3120-N321-P7T1-W19DG4-3A by E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W19DG4-3A

E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W19DG4-3A by E-t-a Elektrotechnische Apparate is a 3A thermal circuit breaker with a rated AC voltage of 240V. It features corrosion/moisture resistance, IP40 protection, and quick connect terminals. Ideal for panel mounting applications, it has a rated breaking capacity of 5000A and operates within temperatures ranging from -30°C to 60°C.

3 A

5 kA

240 V

50 V

Rocker

Manual On/Off

2

Thermal Circuit Breaker

Rated breaking capacity at 50 VDC: 1000 A

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion/Moisture Resistant; IP00; IP40

CCC; CE; CSA; CQC; KTL; UL; VDE

Quick Connect

Panel Mount

ESX10-TB-101-DC24V-3A-E by E-t-a Elektrotechnische Apparate

ESX10-TB-101-DC24V-3A-E

E-t-a Elektrotechnische Apparate

ESX10-TB-101-DC24V-3A-E by E-t-a Elektrotechnische Apparate is a 3A circuit breaker with SNAP ON terminals, DIN-RAIL MOUNT feature, and RESET BUTTON actuator. It operates at -25 to 60 °C with IP20 protection, suitable for equipment leakage protection in various industries. Compliant with ATEX, CSA, CUL, DNV, IEC, TUV, UKCA, UL standards.

3 A

24 V

3.268 in (83 mm)

3.15 in (80 mm)

0.492 in (12.5 mm)

Reset Button

Trip

1

Equipment Leakage Circuit Breaker

-25 °C (-13 °F)

60 °C (140 °F)

IP20

ATEX; CSA; CUL; DNV; IEC; TUV; UKCA; UL

Snap On

DIN Rail Mount