Part RoHS Manufacturer Description Rated Current Rated Breaking Capacity Rated AC Voltage Rated DC Voltage Body Height Body Length/Diameter Body Width Dimensions Actuator Type Blow Characteristic Trip Time/Delay Circuit Function No. of Poles Circuit Protection Type Additional Features Minimum Operating Temperature Maximum Operating Temperature Environmental Characteristics Reference Standard Manufacturer Series JESD-609 Code Terminal Shape Terminal Finish Mounting Feature Packing Method
3RV2011-4AA15 by Siemens

3RV2011-4AA15

Siemens

Siemens 3RV2011-4AA15 is a 16A circuit breaker with 690V AC voltage rating. Its thermal magnetic protection and 2000A breaking capacity make it ideal for DIN-rail mounting in industrial applications. With IP20 protection, this rotary handle actuator offers reliable circuit trip functionality at temperatures ranging from -20°C to 60°C.

16 A

2 kA

690 V

3.819 in (97 mm)

3.819 in (97 mm)

1.772 in (45 mm)

3.819 x 1.772 x 3.819 in (97 x 45 x 97 mm)

Rotary Handle

Trip

3

Thermal Magnetic Circuit Breaker

-20 °C (-4 °F)

60 °C (140 °F)

IP20

Screw And Snap On

DIN Rail Mount

3RV2121-4AA10 by Siemens

3RV2121-4AA10

Siemens

Siemens 3RV2121-4AA10 is a 16A circuit breaker with rated voltage of 690V. It features thermal magnetic protection, DIN-rail mounting, and IP20 environmental rating. Ideal for relay trip applications with rotary handle actuator and compact dimensions of 97mm x 65mm x 97mm.

16 A

2 kA

690 V

3.819 in (97 mm)

3.819 in (97 mm)

2.559 in (65 mm)

3.819 x 2.559 x 3.819 in (97 x 65 x 97 mm)

Rotary Handle

Relay Trip

3

Thermal Magnetic Circuit Breaker

-20 °C (-4 °F)

60 °C (140 °F)

IP20

Screw And Snap On

DIN Rail Mount

PCG-BA-24-616-1DA-E12 by Carling Technologies

PCG-BA-24-616-1DA-E12

Carling Technologies

Carling Technologies' PCG-BA-24-616-1DA-E12 is a 240V, 16A circuit breaker with a rated breaking capacity of 3000A. Featuring a panel mount and handle actuator, it is ideal for equipment leakage protection in various applications. Compliant with CSA and UL standards, it operates b/w -35°C to 66°C temperatures efficiently.

16 A

3 kA

240 V

2.975 in (75.57 mm)

3.8 in (96.52 mm)

2.265 in (57.53 mm)

Handle

Series Trip

2

Equipment Leakage Circuit Breaker

-35 °C (-31 °F)

66 °C (150.8 °F)

CSA; UL

Stud

Panel Mount

3RV2011-4AA10 by Siemens

3RV2011-4AA10

Siemens

Siemens 3RV2011-4AA10 is a 16A circuit breaker with rated AC voltage of 690V. Featuring thermal magnetic protection, it has a breaking capacity of 2000A and operates b/w -20°C to 60°C. Ideal for DIN-rail mounting, its compact dimensions make it suitable for various industrial applications.

16 A

2 kA

690 V

3.815 in (96.9 mm)

3.819 in (97 mm)

1.772 in (45 mm)

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Handle

Trip

3

Thermal Magnetic Circuit Breaker

Interrupting current max at 450 VDC: 10000 A

-20 °C (-4 °F)

60 °C (140 °F)

IP20

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

Snap On

DIN Rail Mount

3RV2021-4AA10 by Siemens

3RV2021-4AA10

Siemens

Siemens 3RV2021-4AA10 is a 16A circuit breaker with rated AC voltage of 690V. Featuring thermal magnetic protection, it has a breaking capacity of 2000A and operates b/w -20°C to 60°C. With DIN-rail mounting, it is ideal for industrial applications requiring reliable circuit protection.

16 A

2 kA

690 V

3.815 in (96.9 mm)

3.819 in (97 mm)

1.772 in (45 mm)

3.819 x 1.772 x 3.815 in (97 x 45 x 96.9 mm)

Handle

Instantaneous

Trip

3

Thermal Magnetic Circuit Breaker

Interrupting current max at 450 VDC: 10000 A

-20 °C (-4 °F)

60 °C (140 °F)

IP20

ATEX; CCC; CE; CSA; EAC; IECEX; KC; UL; VDE

Snap On

DIN Rail Mount

5SY4216-8 by Siemens

5SY4216-8

Siemens

Siemens 5SY4216-8 is a 16A circuit breaker with rated AC voltage of 400V. Featuring thermal magnetic protection, it has a breaking capacity of 10kA and DIN-rail mounting. With IP20 rating, it's ideal for industrial applications requiring reliable circuit protection.

16 A

10 kA

400 V

2.992 in (76 mm)

3.535 in (89.8 mm)

1.386 in (35.2 mm)

3.535 x 1.386 x 2.992 in (89.8 x 35.2 x 76 mm)

Trip

2

Thermal Magnetic Circuit Breaker

IP20

CCC; CE; IMQ; RCM; UL; VDE

Snap On

DIN Rail Mount

1140-G151-P7M1-16A by E-t-a Elektrotechnische Apparate

1140-G151-P7M1-16A

E-t-a Elektrotechnische Apparate

1140-G151-P7M1-16A by E-t-a Elektrotechnische Apparate is a 16A thermal circuit breaker with a rated AC voltage of 250V. Featuring corrosion resistance and IP40 protection, it has a compact body measuring 19mm x 11in x 60.3mm. Ideal for panel mounting applications, this breaker offers trip-free operation and complies with CSA, UL, and VDE standards.

16 A

2 kA

250 V

50 V

2.374 in (60.3 mm)

0.748 in (19 mm)

0.433 in (11 mm)

Push To Reset

Trip Free

2

Thermal Circuit Breaker

-20 °C (-4 °F)

60 °C (140 °F)

Corrosion Resistant; IP00; IP40

CSA; UL; VDE

Quick Connect

Panel Mount

J7MC-3P-16 by Omron

J7MC-3P-16

Omron

THERMAL MAGNETIC CIRCUIT BREAKER; Mounting Feature: DIN RAIL; Rated AC Voltage: 440 V; Rated Current: 16 A; Terminal Shape: SCREW; No. of Poles: 3;

16 A

10 kA

440 V

2.941 in (74.7 mm)

5.118 in (130 mm)

1.772 in (45 mm)

Rocker

Trip

3

Thermal Magnetic Circuit Breaker

-20 °C (-4 °F)

60 °C (140 °F)

IP20

CCC; CE; CUL; IEC; PSE; TUV; UL

Screw

DIN Rail Mount

J7MC-3R-16 by Omron

J7MC-3R-16

Omron

THERMAL MAGNETIC CIRCUIT BREAKER; Mounting Feature: DIN RAIL; Rated AC Voltage: 440 V; Rated Current: 16 A; Terminal Shape: SCREW; Body Length/Diameter: 130 mm;

16 A

105 kA

440 V

3.728 in (94.7 mm)

5.118 in (130 mm)

1.772 in (45 mm)

Rotary Knob

Manual On/Off

3

Thermal Magnetic Circuit Breaker

-20 °C (-4 °F)

60 °C (140 °F)

IP20

CCC; CE; CUL; IEC; PSE; TUV; UL

Screw

DIN Rail Mount

3120-N321-P7T1-W19DG4-16A by E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W19DG4-16A

E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W19DG4-16A by E-t-a Elektrotechnische Apparate is a 16A thermal circuit breaker with a rated AC voltage of 240V. It features corrosion/moisture resistance, quick connect terminals, and an IP40 environmental rating. Ideal for panel mounting applications, this circuit breaker has a rated breaking capacity of 5000A and operates within temperatures ranging from -30°C to 60°C.

16 A

5 kA

240 V

50 V

Rocker

Manual On/Off

2

Thermal Circuit Breaker

Rated breaking capacity at 50 VDC: 1000 A

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion/Moisture Resistant; IP00; IP40

CCC; CE; CSA; CQC; KTL; UL; VDE

Quick Connect

Panel Mount

1324402 by Phoenix Contact

1324402

Phoenix Contact

Phoenix Contact 1324402 is a 16A thermal circuit breaker with a rated AC voltage of 250V. Featuring IP40 environmental protection, it has a max operating temperature of 60°C and min of -20°C. Ideal for panel mounting in various applications requiring reliable circuit protection.

16 A

200 A

250 V

72 V

0.961 in (24.4 mm)

1.752 in (44.5 mm)

0.374 in (9.5 mm)

Push Button

Trip

Thermal Circuit Breaker

-20 °C (-4 °F)

60 °C (140 °F)

IP00; IP40

CCC; CSA; CUL; UL; VDE

Quick Connect

Panel Mount

Bulk