Loading...
Part# Info Electrical Specifications Physical Dimensions Fuse Characteristics Operational Environment Design and Compliance Mounting and Packing
Part RoHS Manufacturer Description Rated Current Rated Breaking Capacity Rated AC Voltage Rated DC Voltage Body Height Body Length/Diameter Body Width Dimensions Actuator Type Blow Characteristic Trip Time/Delay Circuit Function No. of Poles Circuit Protection Type Additional Features Minimum Operating Temperature Maximum Operating Temperature Environmental Characteristics Reference Standard Manufacturer Series JESD-609 Code Terminal Shape Terminal Finish Mounting Feature Packing Method
W68-X2Q12-15 by TE Connectivity

W68-X2Q12-15

TE Connectivity

TE Connectivity's W68-X2Q12-15 is a 15A magnetic circuit breaker with 277V AC voltage rating and 2.2s trip delay. Featuring quick connect terminals, toggle actuator, and panel mount design, it offers a rated breaking capacity of 5000A. Ideal for series trip applications requiring reliable circuit protection in compact spaces.

15 A

5 kA

277 V

50.8mm X 38.1mm X 51.89mm

Toggle

2.2 s

Series Trip

2

Magnetic Circuit Breaker

Quick Connect

Panel Mount

W67-X2Q12-15 by TE Connectivity

W67-X2Q12-15

TE Connectivity

TE Connectivity's W67-X2Q12-15 is a 15A circuit breaker with rated AC voltage of 277V and trip time of 2.2s. It features quick connect terminals, fungus and moisture resistance, and operates in temperatures from -40°C to 85°C. Ideal for panel mounting applications requiring magnetic circuit protection with CSA and UL standards compliance.

15 A

5 kA

277 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.75 in (19.05 mm)

2 x 0.75 x 1.64 in (50.8 x 19.05 x 41.66 mm)

Toggle

Standard

2.2 s

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Fungus Resistant; Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

3C15UR by Altech

3C15UR

Altech

Altech's 3C15UR is a 15A thermal magnetic circuit breaker with a rated AC voltage of 480V. Featuring an actuator type toggle and DIN rail mounting, it offers a rated breaking capacity of 10kA. Ideal for circuit protection in industrial applications with environmental characteristics rated at IP20.

15 A

10 kA

480 V

2.693 in (68.4 mm)

3.516 in (89.3 mm)

2.067 in (52.5 mm)

Toggle

Trip

3

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

55 °C (131 °F)

IP20

CE; CUL; UL

Snap On

DIN Rail Mount

Bulk

2DU15L by Altech

2DU15L

Altech

The Altech 2DU15L is a 15A circuit breaker with a rated AC voltage of 480V. Featuring thermal magnetic protection, it has a breaking capacity of 10000A and operates within -25 to 60°C. Ideal for DIN rail mounting in applications requiring reliable circuit protection under varying environmental conditions.

15 A

10 kA

480 V

2.362 in (60 mm)

4.291 in (109 mm)

1.378 in (35 mm)

Toggle Handle

Trip

2

Thermal Magnetic Circuit Breaker

-25 °C (-13 °F)

60 °C (140 °F)

IP20

CE, CUL, UL

Snap On

DIN Rail Mount

Bulk

W31-X2M1G-15 by TE Connectivity

W31-X2M1G-15

TE Connectivity

TE Connectivity's W31-X2M1G-15 is a 15A thermal circuit breaker with 240V AC and 50V DC ratings. Featuring a trip time of 6s, it offers corrosion/moisture resistance and panel mount installation. Ideal for series trip applications, this toggle actuator breaker has a rated breaking capacity of 1000A.

15 A

1 kA

240 V

50 V

1.6 in (40.64 mm)

1.384 in (35.15 mm)

0.69 in (17.53 mm)

Toggle

6 s

Series Trip

1

Thermal Circuit Breaker

Corrosion/Environment/Moisture Resistant

CSA; UL

Screw

Panel Mount

CMB-153-11C3N-B-A/15 by Carling Technologies

CMB-153-11C3N-B-A/15

Carling Technologies

Carling Technologies CMB-153-11C3N-B-A/15 is a 15A thermal circuit breaker with 250V AC and 32V DC ratings. Featuring push-to-reset actuator, it's ideal for panel mount applications requiring manual on/off control. With a compact body size of 29.3x14x45.2 mm, it operates b/w -10°C to 60°C temperature range ensuring reliable circuit protection up to 1000A breaking capacity.

15 A

1 kA

250 V

32 V

1.78 in (45.2 mm)

1.154 in (29.3 mm)

0.551 in (14 mm)

Push To Reset

Manual On/Off

1

Thermal Circuit Breaker

Rated breaking capacity at 32 VDC: 2500 A

-10 °C (14 °F)

60 °C (140 °F)

Quick Connect

Panel Mount

CMB-153-11C3N-B-A by Carling Technologies

CMB-153-11C3N-B-A

Carling Technologies

Carling Technologies CMB-153-11C3N-B-A is a 15A thermal circuit breaker with 250V AC and 32V DC ratings. Featuring push-to-reset actuator, it's panel-mounted for series trip applications. With CSA, CE, CUL, TUV, UL certifications, it operates b/w -10°C to 60°C temperatures effectively.

15 A

1 kA

250 V

32 V

1.78 in (45.2 mm)

1.154 in (29.3 mm)

0.551 in (14 mm)

Push To Reset

Series Trip

1

Thermal Circuit Breaker

-10 °C (14 °F)

60 °C (140 °F)

CSA; CE; CUL; TUV; UL

Quick Connect

Panel Mount

CA2-B0-34-615-121-C by Carling Technologies

CA2-B0-34-615-121-C

Carling Technologies

Carling Technologies CA2-B0-34-615-121-C is a 15A circuit breaker with 480V AC voltage rating. Featuring magnetic protection, it has a breaking capacity of 10kA and operates b/w -40°C to 85°C. Ideal for panel mounting in UL-standard applications requiring reliable series trip functionality.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B0-34-615-121-E by Carling Technologies

CA2-B0-34-615-121-E

Carling Technologies

Carling Technologies CA2-B0-34-615-121-E is a 15A magnetic circuit breaker with 480V AC and 150V DC ratings. Featuring a panel mount design, it has a compact body measuring 47x38.48x63.5mm, suitable for series trip applications in various industries.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

CA2-B0-34-615-121-I by Carling Technologies

CA2-B0-34-615-121-I

Carling Technologies

Carling Technologies CA2-B0-34-615-121-I is a 15A magnetic circuit breaker with 480V AC and 150V DC ratings. Featuring a compact design (47x38.48x63.5 mm), it has a high breaking capacity of 10000A. Ideal for panel mounting in series trip circuits, UL certified for applications requiring reliable overcurrent protection up to 85°C and down to -40°C.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

AA1-B0-34-615-331-C by Carling Technologies

AA1-B0-34-615-331-C

Carling Technologies

Carling Technologies AA1-B0-34-615-331-C is a 15A magnetic circuit breaker with 277V AC and 80V DC ratings. Its corrosion-resistant design makes it ideal for panel mounting in applications requiring series trip circuit protection. Operating temperatures range from -40°C to 85°C, meeting CSA and UL standards.

15 A

5 kA

277 V

80 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

AA1-B0-34-615-3B1-C by Carling Technologies

AA1-B0-34-615-3B1-C

Carling Technologies

Carling Technologies AA1-B0-34-615-3B1-C is a 15A magnetic circuit breaker with 277V AC and 80V DC ratings. It features corrosion-resistant design, screw terminals, and panel mount for series trip applications in environments ranging from -40°C to 85°C. UL and CSA certified.

15 A

5 kA

277 V

80 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

AA1-B0-34-615-3B1-I by Carling Technologies

AA1-B0-34-615-3B1-I

Carling Technologies

Carling Technologies AA1-B0-34-615-3B1-I is a 15A magnetic circuit breaker with 277V AC and 80V DC ratings. It features corrosion/moisture resistance, screw terminals, and a panel mount for series trip applications. Operating temperatures range from -40°C to 85°C, meeting CSA and UL standards.

15 A

5 kA

277 V

80 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

AA1-B0-34-615-3D1-C by Carling Technologies

AA1-B0-34-615-3D1-C

Carling Technologies

Carling Technologies AA1-B0-34-615-3D1-C is a 15A magnetic circuit breaker with 277V AC and 80V DC ratings. It features corrosion/moisture resistance, screw terminals, and a panel mount for series trip applications. Operating temperatures range from -40°C to 85°C, meeting CSA and UL standards.

15 A

5 kA

277 V

80 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

AA1-B0-34-615-3G2-C by Carling Technologies

AA1-B0-34-615-3G2-C

Carling Technologies

Carling Technologies AA1-B0-34-615-3G2-C is a 15A magnetic circuit breaker with 277V AC and 80V DC ratings. It features corrosion-resistant design, screw terminals, and panel mount for series trip applications. Operating temperatures range from -40°C to 85°C, meeting CSA and UL standards.

15 A

5 kA

277 V

80 V

1.64 in (41.66 mm)

2 in (50.8 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

AM1-B0-14-615-901-C by Carling Technologies

AM1-B0-14-615-901-C

Carling Technologies

Carling Technologies AM1-B0-14-615-901-C is a 15A magnetic circuit breaker with 7500A rated breaking capacity. It features a screw terminal shape, toggle actuator type, and corrosion/moisture resistant design. Ideal for panel mounting in applications requiring series trip circuit protection at temperatures ranging from -40°C to 85°C.

15 A

7.5 kA

80 V

1.817 in (46.15 mm)

2 in (50.8 mm)

0.74 in (18.8 mm)

Toggle

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL

Screw

Panel Mount

1620-2-15A by E-t-a Elektrotechnische Apparate

1620-2-15A

E-t-a Elektrotechnische Apparate

1620-2-15A by E-t-a Elektrotechnische Apparate is a 15 A thermal circuit breaker with a rated breaking capacity of 150 A. Featuring corrosion resistance and IP50 protection, it has a quick connect terminal shape and operates b/w -40 to 85 °C. Ideal for panel mounting in applications requiring reliable circuit protection.

15 A

150 A

12 V

0.984 in (25 mm)

0.524 in (13.3 mm)

0.276 in (7 mm)

Modified Reset

Trip

1

Thermal Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion Resistant; IP00; IP50

Quick Connect

Panel Mount

1620-3-15A by E-t-a Elektrotechnische Apparate

1620-3-15A

E-t-a Elektrotechnische Apparate

1620-3-15A by E-t-a Elektrotechnische Apparate is a 15A thermal circuit breaker with a rated breaking capacity of 150A. Featuring corrosion resistance and IP40 protection, it has a quick connect terminal shape and reset button actuator. Ideal for panel mounting in applications requiring reliable circuit protection at temperatures ranging from -40°C to 85°C.

15 A

150 A

12 V

0.984 in (25 mm)

0.524 in (13.3 mm)

0.276 in (7 mm)

Reset Button

Trip

1

Thermal Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion Resistant; IP00; IP40

Quick Connect

Panel Mount

1658-G21-01-P13-15A by E-t-a Elektrotechnische Apparate

1658-G21-01-P13-15A

E-t-a Elektrotechnische Apparate

1658-G21-01-P13-15A by E-t-a Elektrotechnische Apparate is a 15A thermal circuit breaker with a rated AC voltage of 240V. It features corrosion/moisture resistance, IP40 protection, and operates in temperatures from -20°C to 60°C. Ideal for panel mounting applications requiring trip-free circuit protection.

15 A

1 kA

240 V

28 V

1.063 in (27 mm)

1.26 in (32 mm)

0.535 in (13.6 mm)

Push To Reset

Trip Free

1

Thermal Circuit Breaker

-20 °C (-4 °F)

60 °C (140 °F)

Corrosion/Moisture Resistant; IP00; IP40

CSA; CUL; UL

Quick Connect

Panel Mount

Bulk

4230-T130-K0CE-15A by E-t-a Elektrotechnische Apparate

4230-T130-K0CE-15A

E-t-a Elektrotechnische Apparate

E-t-a Elektrotechnische Apparate's 4230-T130-K0CE-15A is a 3-pole circuit breaker with a rated current of 15A and rated AC voltage of 480V. Featuring thermal magnetic protection, it has a breaking capacity of 5000A and operates in temperatures ranging from -35°C to 70°C. Ideal for DIN rail mounting, this corrosion-resistant breaker with IP20 rating is suitable for various industrial applications.

15 A

5 kA

480 V

2.37 in (60.2 mm)

3.228 in (82 mm)

2.083 in (52.9 mm)

Toggle Handle

Trip Free

3

Thermal Magnetic Circuit Breaker

-35 °C (-31 °F)

70 °C (158 °F)

Corrosion Resistant; IP20

UL; TUV

Snap On

DIN Rail Mount

CA2-B0-34-615-121-R by Carling Technologies

CA2-B0-34-615-121-R

Carling Technologies

CA2-B0-34-615-121-R by Carling Technologies is a 15A magnetic circuit breaker with 250V AC and 80V DC ratings. With corrosion resistance, it's ideal for panel mounting in applications requiring series trip circuit protection up to 5000A breaking capacity. Operating b/w -40°C to 85°C, it meets CSA, TUV, and UL standards.

15 A

5 kA

250 V

80 V

1.85 in (47 mm)

2.5 in (63.5 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; TUV; UL

Stud

Panel Mount

AN1-B0-20-615-113-D by Carling Technologies

AN1-B0-20-615-113-D

Carling Technologies

Carling Technologies AN1-B0-20-615-113-D is a 15A circuit breaker with 250V AC voltage rating. Featuring corrosion/moisture resistance, it has quick connect terminals and push-to-reset actuator. Ideal for panel mounting, this breaker offers a rated breaking capacity of 1000A for series trip applications.

15 A

1 kA

250 V

1.64 in (41.66 mm)

2.156 in (54.76 mm)

0.745 in (18.92 mm)

Push To Reset

Series Trip

1

Magnetic Circuit Breaker

Standards: MIL-PRF-55629, MIL-STD-202

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Quick Connect

Panel Mount

MS2-B-20-615-1-1CB-A-0DC by Carling Technologies

MS2-B-20-615-1-1CB-A-0DC

Carling Technologies

Carling Technologies MS2-B-20-615-1-1CB-A-0DC is a 240V, 15A circuit breaker with IP68 rating. Featuring sealed toggle actuator and quick connect terminals, it offers series trip circuit function. Ideal for panel mounting applications in environments ranging from -40°C to 85°C.

15 A

2 kA

240 V

2.158 in (54.81 mm)

1.375 in (34.93 mm)

1.3 in (33.02 mm)

Sealed Toggle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Moisture Resistant; IP68;

CUL; UL

Quick Connect

Panel Mount

GA1-B0-20-615-11-DC by Carling Technologies

GA1-B0-20-615-11-DC

Carling Technologies

Carling Technologies GA1-B0-20-615-11-DC is a 15A magnetic circuit breaker with 240V AC voltage rating. It features corrosion/moisture resistance, DIN-rail mounting, and CSA/UL certification. Ideal for series trip applications, it has a breaking capacity of 3000A and operates b/w -40°C to 85°C.

15 A

3 kA

240 V

2.62 in (66.55 mm)

3.625 in (92.08 mm)

0.688 in (17.48 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA, UL

Snap On

DIN Rail Mount

3120-N311-P7T1-W02D-15A by E-t-a Elektrotechnische Apparate

3120-N311-P7T1-W02D-15A

E-t-a Elektrotechnische Apparate

3120-N311-P7T1-W02D-15A by E-t-a Elektrotechnische Apparate is a 15A thermal circuit breaker with a rated AC voltage of 240V. Featuring a compact body size of 56.4mm x 25mm x 33mm, it is corrosion-resistant and has an IP40 environmental rating. Ideal for panel mounting applications, this breaker offers trip-free circuit protection with a high breaking capacity of 5000A.

15 A

5 kA

240 V

50 V

1.299 in (33 mm)

2.22 in (56.4 mm)

0.984 in (25 mm)

Rocker

Trip Free

1

Thermal Circuit Breaker

Rated breaking capacity at 50 VDC: 1000 A

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant; IP00; IP40

CCC; CSA; KC; UL; VDE

Quick Connect

Panel Mount

3120-N321-P7T1-W02D-15A by E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W02D-15A

E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W02D-15A by E-t-a Elektrotechnische Apparate is a 15A thermal circuit breaker with a rated AC voltage of 240V. It features corrosion-resistant properties, IP40 protection, and quick connect terminals. Ideal for panel mounting applications, it has a compact body size of 56.4mm x 25mm x 33mm and operates within -30°C to 60°C temperature range.

15 A

5 kA

240 V

50 V

1.299 in (33 mm)

2.22 in (56.4 mm)

0.984 in (25 mm)

Rocker

Trip Free

2

Thermal Circuit Breaker

Rated breaking capacity at 50 VDC: 1000 A

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant; IP00; IP40

CCC; CSA; KC; UL; VDE

Quick Connect

Panel Mount

3120-N323-P7T1-W01D-15A by E-t-a Elektrotechnische Apparate

3120-N323-P7T1-W01D-15A

E-t-a Elektrotechnische Apparate

3120-N323-P7T1-W01D-15A by E-t-a Elektrotechnische Apparate is a 15A thermal circuit breaker with a rated AC voltage of 240V. It features a corrosion-resistant body measuring 56.4mm x 25in x 33mm, suitable for panel mounting applications. With a rated breaking capacity of 5000A and trip-free circuit function, it meets standards like CCC, CSA, KC, UL, and VDE.

15 A

5 kA

240 V

50 V

1.299 in (33 mm)

2.22 in (56.4 mm)

0.984 in (25 mm)

Rocker

Trip Free

2

Thermal Circuit Breaker

Rated breaking capacity at 50 VDC: 1000 A

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion Resistant; IP00; IP40

CCC; CSA; KC; UL; VDE

Quick Connect

Panel Mount

209-1-1-62-4-9-15-V by Sensata Technologies

209-1-1-62-4-9-15-V

Sensata Technologies

Sensata Technologies' 209-1-1-62-4-9-15-V is a moisture-resistant circuit breaker with rated AC voltage of 240V and current of 15A. Featuring a magnetic trip-free circuit protection type, it has a breaking capacity of 5000A. Ideal for panel mounting applications, this toggle actuator breaker meets CSA, CUL, UL, and VDE standards.

15 A

5 kA

240 V

3.55 in (90.17 mm)

5.125 in (130.18 mm)

1.026 in (26.06 mm)

Toggle

Trip Free

1

Magnetic Circuit Breaker

Moisture Resistant

CSA; CUL; UL; VDE

Stud

Panel Mount

4-1393249-1 by TE Connectivity

4-1393249-1

TE Connectivity

TE Connectivity 4-1393249-1 is a 15A thermal circuit breaker with 250V AC and 50V DC ratings. Featuring a quick connect terminal shape, it has a trip time of 6s and rated breaking capacity of 1000A. Ideal for panel mount applications in series trip circuits.

15 A

1 kA

250 V

50 V

1.494 in (37.96 mm)

1.375 in (34.93 mm)

0.66 in (16.76 mm)

Push To Reset

6 s

Series Trip

1

Thermal Circuit Breaker

Quick Connect

Panel Mount

W91-X113-15 by TE Connectivity

W91-X113-15

TE Connectivity

TE Connectivity's W91-X113-15 is a 15A circuit breaker with 277V AC voltage rating and 0.15s trip time. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 5000A. Ideal for panel mounting in applications requiring series trip circuit function.

15 A

5 kA

277 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

0.75 in (19.05 mm)

Toggle

150 ms

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

W93-X112-15 by TE Connectivity

W93-X112-15

TE Connectivity

TE Connectivity's W93-X112-15 is a 15A circuit breaker with 277V AC voltage rating and 2.2s trip delay. Ideal for panel mounting, it features a magnetic protection type and toggle actuator, making it suitable for series trip applications in various industries.

15 A

5 kA

277 V

1.845 in (46.86 mm)

2.5 in (63.5 mm)

2.25 in (57.15 mm)

Toggle

2.2 s

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Stud

Panel Mount

CTB-B-B-15 by Carling Technologies

CTB-B-B-15

Carling Technologies

Carling Technologies' CTB-B-B-15 is a 15A thermal circuit breaker with 250V AC and 50V DC ratings. Featuring a quick connect terminal shape, rocker actuator type, and panel mounting feature, it ensures series trip circuit protection with a high breaking capacity of 1000A. Ideal for various applications requiring reliable overcurrent protection.

15 A

1 kA

250 V

50 V

1.535 in (38.99 mm)

0.76 in (19.31 mm)

0.76 in (19.31 mm)

Rocker

Series Trip

1

Thermal Circuit Breaker

CE; CUL; UL; VDE

Quick Connect

Panel Mount

CA3-B0-20-615-121-C by Carling Technologies

CA3-B0-20-615-121-C

Carling Technologies

Carling Technologies CA3-B0-20-615-121-C is a 250V, 15A magnetic circuit breaker with corrosion resistance. Featuring a stud terminal shape and panel mount, it has a rated breaking capacity of 3000A. Ideal for applications requiring series trip circuit protection in environments with temperatures ranging from -40°C to 85°C.

15 A

3 kA

250 V

1.85 in (47 mm)

2.5 in (63.5 mm)

2.265 in (57.53 mm)

Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA, UL

Stud

Panel Mount

CB4-B0-24-615-1C1-D by Carling Technologies

CB4-B0-24-615-1C1-D

Carling Technologies

Carling Technologies CB4-B0-24-615-1C1-D is a 15A magnetic circuit breaker with 250V AC voltage rating. It features corrosion/moisture resistance, stud terminals, and a series trip circuit function. Ideal for panel mounting applications, it meets CSA, UL, and VDE standards while offering a rated breaking capacity of 3000A.

15 A

3 kA

250 V

1.85 in (47 mm)

2.5 in (63.5 mm)

3.015 in (76.58 mm)

Handle

Series Trip

4

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA, UL, VDE

Stud

Panel Mount

5SJ4218-7HG41 by Siemens

5SJ4218-7HG41

Siemens

Siemens 5SJ4218-7HG41 is a 15A circuit breaker with rated AC voltage of 400V. It offers thermal protection with a breaking capacity of 14000A. Designed for DIN-rail mounting, it is ideal for applications requiring trip circuit function and environmental resistance (IP20/IP40).

15 A

14 kA

400 V

3.031 in (77 mm)

4.283 in (108.8 mm)

1.386 in (35.2 mm)

4.283 x 1.386 x 3.031 in (108.8 x 35.2 x 77 mm)

Trip

2

Thermal Circuit Breaker

Environmental Characteristics: Sealed

-25 °C (-13 °F)

55 °C (131 °F)

Environment Resistant; IP20; IP40

CCC; CE; UL; VDE

Snap On

DIN Rail Mount

CA1-B0-34-615-121-D by Carling Technologies

CA1-B0-34-615-121-D

Carling Technologies

CA1-B0-34-615-121-D by Carling Technologies is a 15A magnetic circuit breaker with a rated AC voltage of 250V. It features corrosion/moisture resistance and operates in temperatures ranging from -40 to 85°C. Ideal for panel mounting, this breaker has a rated breaking capacity of 5000A and is suitable for series trip applications.

15 A

5 kA

250 V

80 V

1.85 in (47 mm)

2.5 in (63.5 mm)

0.755 in (19.18 mm)

Handle

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA; UL; VDE

Stud

Panel Mount

CA2-B0-34-615-121-D by Carling Technologies

CA2-B0-34-615-121-D

Carling Technologies

Carling Technologies CA2-B0-34-615-121-D is a 15A circuit breaker with 480V AC voltage rating. Featuring a magnetic circuit protection type, it has a rated breaking capacity of 10kA. Ideal for panel mounting applications in UL standard compliant setups.

15 A

10 kA

480 V

150 V

2.5 in (63.5 mm)

1.85 in (47 mm)

1.515 in (38.48 mm)

Handle

Series Trip

2

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

UL

Stud

Panel Mount

DA3-B0-20-615-121-C by Carling Technologies

DA3-B0-20-615-121-C

Carling Technologies

Carling Technologies DA3-B0-20-615-121-C is a 15A magnetic circuit breaker with 277V AC voltage rating. Featuring moisture-resistant design, it has a breaking capacity of 5000A and operates in temperatures ranging from -40°C to 85°C. Ideal for panel mounting applications requiring series trip circuit protection.

15 A

5 kA

277 V

2.165 in (54.99 mm)

3.612 in (91.75 mm)

2.265 in (57.53 mm)

Toggle Handle

Series Trip

3

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Moisture Resistant

CSA; UL

Screw

Panel Mount

3120-N321-P7T1-W19DG4-15A by E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W19DG4-15A

E-t-a Elektrotechnische Apparate

3120-N321-P7T1-W19DG4-15A by E-t-a Elektrotechnische Apparate is a 15 A thermal circuit breaker with a rated AC voltage of 240 V. It features corrosion/moisture resistance, quick connect terminals, and an operating temperature range from -30 to 60 °C. Ideal for panel mounting applications requiring manual on/off control in various industries.

15 A

5 kA

240 V

50 V

Rocker

Manual On/Off

2

Thermal Circuit Breaker

Rated breaking capacity at 50 VDC: 1000 A

-30 °C (-22 °F)

60 °C (140 °F)

Corrosion/Moisture Resistant; IP00; IP40

CCC; CE; CSA; CQC; KTL; UL; VDE

Quick Connect

Panel Mount