Loading...
Part# Info Electrical Specifications Physical Dimensions Fuse Characteristics Operational Environment Design and Compliance Mounting and Packing
Part RoHS Manufacturer Description Rated Current Rated Breaking Capacity Rated AC Voltage Rated DC Voltage Body Height Body Length/Diameter Body Width Dimensions Actuator Type Blow Characteristic Trip Time/Delay Circuit Function No. of Poles Circuit Protection Type Additional Features Minimum Operating Temperature Maximum Operating Temperature Environmental Characteristics Reference Standard Manufacturer Series JESD-609 Code Terminal Shape Terminal Finish Mounting Feature Packing Method
TS-709-5 by Schurter Ag

TS-709-5

Schurter Ag

Schurter Ag's TS-709-5 is a 5A thermal circuit breaker with 125V AC and 32V DC ratings. Featuring a push-to-reset actuator, it has a trip-free circuit function and quick connect terminals. Ideal for panel mounting applications, this UL-approved device offers a high breaking capacity of 1000A.

5 A

1 kA

125 V

32 V

0.886 in (22.5 mm)

1.161 in (29.5 mm)

0.563 in (14.3 mm)

Push To Reset

Trip Free

1

Thermal Circuit Breaker

UL

Quick Connect

Panel Mount

MD1-B-34-610-1-A42-B-C by Carling Technologies

MD1-B-34-610-1-A42-B-C

Carling Technologies

Carling Technologies MD1-B-34-610-1-A42-B-C is a 10A circuit breaker with 125V AC voltage rating. It features chemical/corrosion/moisture resistance, quick connect terminals, and rocker actuator. Ideal for panel mounting applications requiring magnetic circuit protection with UL/CSA standards compliance.

10 A

1 kA

125 V

80 V

1.53 in (38.86 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Rocker

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

UL; CSA

Quick Connect

Panel Mount

MG1-B-32-410-1-CC1-B-C by Carling Technologies

MG1-B-32-410-1-CC1-B-C

Carling Technologies

Carling Technologies' MG1-B-32-410-1-CC1-B-C is a 125V, 1A circuit breaker with chemical/corrosion/moisture resistance. Featuring an illuminated rocker actuator and quick connect terminals, it has a rated breaking capacity of 1000A. Ideal for panel mounting in applications requiring series trip circuit protection.

1 A

1 kA

125 V

80 V

1.53 in (38.86 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Illuminated Rocker

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

UL; CSA

Quick Connect

Panel Mount

MT1-B-32-410-1-C21-B-C by Carling Technologies

MT1-B-32-410-1-C21-B-C

Carling Technologies

Carling Technologies' MT1-B-32-410-1-C21-B-C is a 1A magnetic circuit breaker with 125V AC and 80V DC ratings. It features chemical/corrosion/moisture resistance, quick connect terminals, and push-pull actuator for panel mounting applications. Operating b/w -40°C to 85°C, it offers a high breaking capacity of 1000A in series trip circuits.

1 A

1 kA

125 V

80 V

1.484 in (37.69 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Push-Pull

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

UL; CSA

Quick Connect

Panel Mount

MT1-B-32-410-1-C23-B-C by Carling Technologies

MT1-B-32-410-1-C23-B-C

Carling Technologies

Carling Technologies' MT1-B-32-410-1-C23-B-C is a 125V, 1A circuit breaker with chemical/corrosion/moisture resistance. Featuring quick connect terminals and push-pull actuator, it has a rated breaking capacity of 1000A. Ideal for panel mounting in applications requiring series trip circuit protection.

1 A

1 kA

125 V

80 V

1.484 in (37.69 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Push-Pull

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

UL; CSA

Quick Connect

Panel Mount

MU1-B-32-410-1-C21-B-C by Carling Technologies

MU1-B-32-410-1-C21-B-C

Carling Technologies

Carling Technologies' MU1-B-32-410-1-C21-B-C is a 125V circuit breaker with 1A rated current and 1000A breaking capacity. It is chemical/corrosion/moisture resistant, suitable for panel mounting in applications requiring series trip circuit protection at temperatures ranging from -40°C to 85°C.

1 A

1 kA

125 V

80 V

1.484 in (37.69 mm)

1.375 in (34.93 mm)

0.68 in (17.27 mm)

Push To Reset

Series Trip

1

Magnetic Circuit Breaker

-40 °C (-40 °F)

85 °C (185 °F)

Chemical/Corrosion/Moisture Resistant

CSA; UL

Quick Connect

Panel Mount

MF1-B-32-410-1-CE3-B-C by Carling Technologies

MF1-B-32-410-1-CE3-B-C

Carling Technologies

MAGNETIC CIRCUIT BREAKER; Mounting Feature: PANEL MOUNT; Rated AC Voltage: 125 V; Rated DC Voltage: 80 V; Rated Current: 1 A; Terminal Shape: QUICK CONNECT;

1 A

360 A

125 V

80 V

1.53 in (38.86 mm)

1.56 in (39.62 mm)

0.77 in (19.56 mm)

Rocker

Series Trip

1

Magnetic Circuit Breaker

Rated breaking capacity at 80 VDC: 600 A

-40 °C (-40 °F)

85 °C (185 °F)

Corrosion/Moisture Resistant

CSA, UL

Quick Connect

Panel Mount