Loading...

2 A Electrical Wires & Cables 63

Electrical Wires & Cables
Part# Info Specs
Part RoHS Manufacturer Description Additional Features Application Approvals (V) Cable Types Conductor Finish Conductor Material Connector Side-1 Connector Side-2 Connector Accessory Type Construction Cross Section Area DIN Conformity Design Diameter Finish Thickness IEC Conformity Insulator Material Jacket Material Length MIL Conformity Material Mounting Option-1 Mounting Option-2 Mounting Style No. of Conductors Maximum Operating Temperature Minimum Operating Temperature Rated Current Rated Voltage Rated DC Voltage Resistance Shielding Stranding Wire Gauge (AWG) Maximum Wire Size Minimum Wire Size Wire & Cable Name
1-1437358-1 by TE Connectivity

1-1437358-1

TE Connectivity

WIRE AND CABLE; Rated Voltage: 300 V; Rated Current: 2 A; Shielding: NO; Conductor Finish: TIN; No. of Conductors: 50;

UL

RIBBON CABLE

TIN

COPPER ALLOY

WIRE AND CABLE

STRANDED

.08 mm2

NO

NO

POLYVINYLCHLORIDE

POLYVINYLCHLORIDE

30.5 mm

NO

50

105 Cel

-20 Cel

2 A

300 V

300 V

NO

7X36

28

28 AWG

FLAT CABLE

2-1437356-9 by TE Connectivity

2-1437356-9

TE Connectivity

TE Connectivity 2-1437356-9 is a UL approved stranded cable with PVC jacket, rated for 300V. Featuring 28 AWG copper alloy conductor, it's ideal for ribbon and flat cable applications. With a max current of 2A and temperature range from -20 to 105°C, it offers versatility in various electrical setups.

UL

RIBBON CABLE

TIN

COPPER ALLOY

WIRE AND CABLE

STRANDED

NO

NO

POLYVINYLCHLORIDE

POLYVINYLCHLORIDE

30.5 mm

NO

10

105 Cel

-20 Cel

2 A

300 V

300 V

NO

7X36

28

28 AWG

FLAT CABLE

5-1437357-5 by TE Connectivity

5-1437357-5

TE Connectivity

TE Connectivity 5-1437357-5 is a UL approved stranded electrical wire with PVC jacket, rated for 300V. Featuring 28 AWG copper alloy conductor, it has 34 conductors in a flat ribbon cable design. Ideal for applications requiring a max current of 2A and operating temperatures from -20°C to 105°C.

UL

RIBBON CABLE

TIN

COPPER ALLOY

WIRE AND CABLE

STRANDED

NO

NO

POLYVINYLCHLORIDE

POLYVINYLCHLORIDE

30.5 mm

NO

34

105 Cel

-20 Cel

2 A

300 V

300 V

NO

7X36

28

28 AWG

FLAT CABLE

1428678 by Phoenix Contact

1428678

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: YES;

POWER LINE STRANDING: 19x0.16, CROSS SECTION AREA (MM2): 0.326

EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

7.8 mm

NO

PP

SANTOPRENE

10 mm

NO

6

80 Cel

-20 Cel

2 A

30 V

77 ohm

YES

19X0.13

22, 24

COMMUNICATION CABLE

1522671 by Phoenix Contact

1522671

Phoenix Contact

Phoenix Contact 1522671 is a stranded communication cable with PUR jacket, PP insulator, and bare copper litz conductor. It has approvals from CUL, EAC, and UL for 30V rated voltage. Ideal for applications requiring a temperature range of -40 to 80 °C, with 8 conductors and a cross-section area of 0.25 mm2.

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.3 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522684 by Phoenix Contact

1522684

Phoenix Contact

Phoenix Contact 1522684 is a stranded communication cable with PUR jacket, PP insulator, and bare copper litz conductor. It has approvals from CUL, EAC, and UL for 30V rated voltage. Ideal for applications requiring a temperature range of -40 to 80 °C, with 8 conductors and a cross-section area of 0.25 mm2.

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.6 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522697 by Phoenix Contact

1522697

Phoenix Contact

Phoenix Contact 1522697 is a stranded communication cable with PUR jacket, rated for 30V. Featuring 8 conductors of bare copper litz, it has a cross section area of 0.25mm2 and can handle up to 2A current. Ideal for applications requiring reliable data transmission in industrial settings.

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

1.5 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522707 by Phoenix Contact

1522707

Phoenix Contact

Phoenix Contact 1522707 is a stranded communication cable with PUR jacket, PP insulator, and bare copper litz conductor. It has approvals from CUL, EAC, and UL for 30V rated voltage. With a temperature range of -40 to 80 °C, it's ideal for applications requiring a 0.25 mm2 cross-section area and 2A rated current.

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

3 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522710 by Phoenix Contact

1522710

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

8

2 A

30 V

NO

COMMUNICATION CABLE

1522723 by Phoenix Contact

1522723

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.3 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522736 by Phoenix Contact

1522736

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.6 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522749 by Phoenix Contact

1522749

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

1.5 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522752 by Phoenix Contact

1522752

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

3 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522765 by Phoenix Contact

1522765

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

8

2 A

30 V

NO

COMMUNICATION CABLE

1522969 by Phoenix Contact

1522969

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.3 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

YES

32X0.10

24

COMMUNICATION CABLE

1522972 by Phoenix Contact

1522972

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.6 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

YES

32X0.10

24

COMMUNICATION CABLE

1522985 by Phoenix Contact

1522985

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

1.5 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

YES

32X0.10

24

COMMUNICATION CABLE

1523007 by Phoenix Contact

1523007

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

8

2 A

30 V

NO

COMMUNICATION CABLE

1523010 by Phoenix Contact

1523010

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.3 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

YES

32X0.10

24

COMMUNICATION CABLE

1523023 by Phoenix Contact

1523023

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.6 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

YES

32X0.10

24

COMMUNICATION CABLE

1523036 by Phoenix Contact

1523036

Phoenix Contact

Phoenix Contact 1523036 is a stranded communication cable with PUR jacket, shielding, and PP insulator. It has 8 conductors of bare copper litz with 0.25 mm2 cross section area. Rated for 30V and 2A, it's ideal for applications requiring flexibility and durability in electrical wiring systems.

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

1.5 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

YES

32X0.10

24

COMMUNICATION CABLE

1523049 by Phoenix Contact

1523049

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

3 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

YES

32X0.10

24

COMMUNICATION CABLE

1523683 by Phoenix Contact

1523683

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

IP65, IP68, IP69K

UL

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

NO

NO

NO

8

90 Cel

-25 Cel

2 A

30 V

NO

COMMUNICATION CABLE

1523696 by Phoenix Contact

1523696

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

UL

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

8

2 A

30 V

NO

COMMUNICATION CABLE

1523939 by Phoenix Contact

1523939

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

UL

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

8

2 A

30 V

NO

COMMUNICATION CABLE

1543207 by Phoenix Contact

1543207

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: PLUG STRAIGHT; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: YES;

UL

BARE COPPER LITZ

PLUG STRAIGHT

PLUG STRAIGHT

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

FOAM PE

PUR

10 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.15 ohm

YES

7X0.16

26

COMMUNICATION CABLE

1551969 by Phoenix Contact

1551969

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

PLUG ANGLED

SOCKET STRAIGHT

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

8

2 A

30 V

NO

COMMUNICATION CABLE

1551972 by Phoenix Contact

1551972

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

PLUG ANGLED

SOCKET ANGLED

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

8

2 A

30 V

NO

COMMUNICATION CABLE

1552191 by Phoenix Contact

1552191

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

UL

PLUG ANGLED

SOCKET STRAIGHT

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

8

2 A

30 V

NO

COMMUNICATION CABLE

1552201 by Phoenix Contact

1552201

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

UL

PLUG ANGLED

SOCKET ANGLED

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

8

2 A

30 V

NO

COMMUNICATION CABLE

1554021 by Phoenix Contact

1554021

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: YES;

EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

FOAM PE

PUR

5 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.15 ohm

YES

7X0.16

26

COMMUNICATION CABLE

1569443 by Phoenix Contact

1569443

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: PLUG STRAIGHT; Rated Voltage: 60 V; Rated Current: 2 A; Shielding: YES;

EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

PLUG STRAIGHT

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

FOAM PE

PUR

.5 mm

NO

4

80 Cel

-40 Cel

2 A

60 V

.15 ohm

YES

7X0.16

26

COMMUNICATION CABLE

1569456 by Phoenix Contact

1569456

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: PLUG STRAIGHT; Rated Voltage: 60 V; Rated Current: 2 A; Shielding: YES;

EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

PLUG STRAIGHT

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

FOAM PE

PUR

1 mm

NO

4

80 Cel

-40 Cel

2 A

60 V

.15 ohm

YES

7X0.16

26

COMMUNICATION CABLE

1569582 by Phoenix Contact

1569582

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 60 V; Rated Current: 2 A; Shielding: YES;

UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

FOAM PE

PUR

16 mm

NO

4

80 Cel

-40 Cel

2 A

60 V

.15 ohm

YES

7X0.16

26

COMMUNICATION CABLE

1428652 by Phoenix Contact

1428652

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: YES;

POWER LINE STRANDING: 19x0.16, CROSS SECTION AREA (MM2): 0.326

EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

7.8 mm

NO

PP

SANTOPRENE

2 mm

NO

6

80 Cel

-20 Cel

2 A

30 V

77 ohm

YES

19X0.13

22, 24

COMMUNICATION CABLE

8777060U500 by Belden

8777060U500

Belden

Belden 8777060U500 is a CE, CEC, CUL, NEC, UL approved communication cable with stranded construction and PVC jacket. Featuring tinned copper conductor material and PP insulator for 300V rated voltage. Ideal for applications requiring -20 to 80 °C operating temperature range.

CE; CEC; CUL; NEC; UL

TINNED COPPER

WIRE AND CABLE

STRANDED

6.93 mm

PP

POLYVINYL CHLORIDE

152.4 mm

6

80 Cel

-20 Cel

2 A

300 V

.049 ohm

NO

7X30

22

COMMUNICATION CABLE

2302049 by Phoenix Contact

2302049

Phoenix Contact

Phoenix Contact 2302049 is a stranded communication cable with approvals from CUL, EAC, and UL. Featuring semi-rigid PVC jacket, it has 9 conductors made of copper with 0.25 mm2 cross-section area. With D-SUB socket and pin strip connectors, this cable is ideal for applications requiring shielding at rated voltage of 60V and operating temperatures from -40 to 70°C.

CUL; EAC; UL

COPPER

D-SUB SOCKET

D-SUB PIN STRIP

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

6.7 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

6 mm

NO

9

70 Cel

-40 Cel

2 A

60 V

.08 ohm

YES

24

COMMUNICATION CABLE

2302078 by Phoenix Contact

2302078

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB SOCKET; Connector Side-2: D-SUB PIN STRIP; Rated Voltage: 60 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

COPPER

D-SUB SOCKET

D-SUB PIN STRIP

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

7.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1.5 mm

NO

15

70 Cel

-40 Cel

2 A

60 V

.08 ohm

YES

24

COMMUNICATION CABLE

2302133 by Phoenix Contact

2302133

Phoenix Contact

Phoenix Contact 2302133 is a stranded communication cable with semi-rigid PVC jacket and shielding. It has 25 conductors, copper material, and rated voltage of 60V. Ideal for D-SUB socket to pin strip connections, it operates b/w -40 to 70°C temperatures at a max current of 2A.

CUL; EAC; UL

COPPER

D-SUB SOCKET

D-SUB PIN STRIP

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

9.8 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1 mm

NO

25

70 Cel

-40 Cel

2 A

60 V

.08 ohm

YES

24

COMMUNICATION CABLE

2302159 by Phoenix Contact

2302159

Phoenix Contact

Phoenix Contact 2302159 is a stranded communication cable with semi-rigid PVC jacket, shielding, and copper conductor. It has 25 conductors, rated for 60V and 2A, with approvals from CUL, EAC, and UL. Ideal for D-SUB socket to pin strip connections in applications requiring -40 to 70°C temperature range.

CUL; EAC; UL

COPPER

D-SUB SOCKET

D-SUB PIN STRIP

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

9.8 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

2 mm

NO

25

70 Cel

-40 Cel

2 A

60 V

.08 ohm

YES

24

COMMUNICATION CABLE

2302162 by Phoenix Contact

2302162

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB SOCKET; Connector Side-2: D-SUB PIN STRIP; Rated Voltage: 60 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

COPPER

D-SUB SOCKET

D-SUB PIN STRIP

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

9.8 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

3 mm

NO

25

70 Cel

-40 Cel

2 A

60 V

.08 ohm

YES

24

COMMUNICATION CABLE

2302269 by Phoenix Contact

2302269

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB SOCKET; Connector Side-2: D-SUB PIN STRIP; Rated Voltage: 60 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

COPPER

D-SUB SOCKET

D-SUB PIN STRIP

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

12.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

.5 mm

NO

50

70 Cel

-40 Cel

2 A

60 V

.08 ohm

YES

24

COMMUNICATION CABLE

2305428 by Phoenix Contact

2305428

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB SOCKET; Connector Side-2: D-SUB SOCKET; Rated Voltage: 60 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

COPPER

D-SUB SOCKET

D-SUB SOCKET

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

6.7 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

2 mm

NO

9

70 Cel

-40 Cel

2 A

60 V

.08 ohm

YES

24

COMMUNICATION CABLE

2305444 by Phoenix Contact

2305444

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB SOCKET; Connector Side-2: D-SUB SOCKET; Rated Voltage: 60 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

COPPER

D-SUB SOCKET

D-SUB SOCKET

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

7.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1 mm

NO

15

70 Cel

-40 Cel

2 A

60 V

.08 ohm

YES

24

COMMUNICATION CABLE

2305457 by Phoenix Contact

2305457

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB SOCKET; Connector Side-2: D-SUB SOCKET; Rated Voltage: 60 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

COPPER

D-SUB SOCKET

D-SUB SOCKET

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

7.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

2 mm

NO

15

70 Cel

-40 Cel

2 A

60 V

.08 ohm

YES

24

COMMUNICATION CABLE

2305460 by Phoenix Contact

2305460

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB SOCKET; Connector Side-2: D-SUB SOCKET; Rated Voltage: 60 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

COPPER

D-SUB SOCKET

D-SUB SOCKET

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

7.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

3 mm

NO

15

70 Cel

-40 Cel

2 A

60 V

.08 ohm

YES

24

COMMUNICATION CABLE

2305541 by Phoenix Contact

2305541

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB SOCKET; Connector Side-2: D-SUB SOCKET; Rated Voltage: 60 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

COPPER

D-SUB SOCKET

D-SUB SOCKET

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

12.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1 mm

NO

50

70 Cel

-40 Cel

2 A

60 V

.08 ohm

YES

24

COMMUNICATION CABLE

2305570 by Phoenix Contact

2305570

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB PIN STRIP; Connector Side-2: D-SUB PIN STRIP; Rated Voltage: 60 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

COPPER

D-SUB PIN STRIP

D-SUB PIN STRIP

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

6.7 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1 mm

NO

9

70 Cel

-40 Cel

2 A

60 V

.08 ohm

YES

24

COMMUNICATION CABLE