4230-T130-K0CU-12A by E-t-a Elektrotechnische Apparate is a 3-pole circuit breaker with a rated current of 12A and rated AC voltage of 480V. It features thermal magnetic circuit protection, trip-free function, and corrosion-resistant design suitable for DIN rail mounting applications. Operating temperatures range from -35°C to 70°C, meeting UL and TUV standards for reliable performance.

Median Price

-

Lifecycle Status

Suppliers In-Stock

0

In-Stock Inventory

< 1k

Distributors (Availability)

Supplier In-Stock 1+ parts 100+ parts 1k+ parts 10k+ parts

Component Stockers USA

USA . 1 parts In-Stock

1+ parts

$83.620

100+ parts

-

1k+ parts

-

10k+ parts

-

1

$83.620

-

-

-

Overview

Discover the power of reliability with the 4230-T130-K0CU-12A circuit breaker by E-t-a Elektrotechnische Apparate. Known for their superior quality and precision engineering, E-t-a products are trusted by professionals worldwide. Ideal for a variety of applications, this circuit breaker provides unrivaled protection for your electrical systems. With a rated current of 12A and a rated breaking capacity of 10000A, this product offers peace of mind and security for your equipment. Invest in the best with E-t-a and experience the difference in performance and durability.

Feature Benefit Bullets

Rated AC Voltage: 480 V

High rated voltage makes this circuit breaker suitable for use in industrial applications and large commercial buildings.

Body Length/Diameter: 116 mm

Compact size allows for easy installation in tight spaces or crowded electrical panels.

Body Width: 52.9 inch

Wide body width provides stability and durability, making it suitable for heavy-duty applications.

Environmental Characteristics: CORROSION RESISTANT; IP20

Corrosion-resistant design ensures longevity and reliability in harsh environments, while IP20 rating protects against solid objects larger than 12 mm.

Terminal Shape: SNAP ON

Snap-on terminals make installation and maintenance quick and easy, saving time and effort.

Body Height: 60.2 mm

Optimal height for efficient cooling and heat dissipation, ensuring the circuit breaker operates reliably under heavy loads.

Rated Current: 12 A

Suitable for low to medium power applications, offering protection against overloads and short circuits within the rated current.

Maximum Operating Temperature: 70 °C

High maximum operating temperature allows for reliable performance in a wide range of environments and applications.

Minimum Operating Temperature: -35 °C

Low minimum operating temperature ensures the circuit breaker can function even in extremely cold conditions, making it versatile and reliable in various climates.

Circuit Protection Type: THERMAL MAGNETIC

Combination of thermal and magnetic protection ensures comprehensive protection against various types of electrical faults, providing peace of mind for users.

Rated Breaking Capacity: 10000 A

High breaking capacity enables the circuit breaker to safely interrupt high fault currents, preventing damage to connected equipment and electrical systems.

Actuator Type: TOGGLE HANDLE

Toggle handle design offers easy manual operation and visual indication of the circuit breaker's status, enhancing user convenience and safety.

Mounting Feature: DIN RAIL

DIN rail mounting simplifies installation and allows for easy integration into existing electrical systems, saving time and effort during setup.

Circuit Function: TRIP FREE

Trip-free mechanism ensures the circuit breaker cannot be held in the ON position during an overload or short circuit, enhancing safety for both equipment and personnel.

No. of Poles: 3

Three poles offer enhanced protection against multiple fault conditions and ensure reliable operation in three-phase electrical systems.

Reference Standard: UL; TUV

Compliance with UL and TUV standards guarantees the circuit breaker's quality, safety, and performance, instilling confidence in users and meeting regulatory requirements.

Technical Specifications

Circuit Breaker 4230-T130-K0CU-12A attributes and parameters. Explore more Circuit Breaker devices from E-t-a Elektrotechnische Apparate

Electrical Specifications

Rated Current:

Rated Breaking Capacity:

10 kA

Rated AC Voltage:

Physical Dimensions

Body Height:

2.37 in (60.2 mm)

Body Length/Diameter:

4.567 in (116 mm)

Body Width:

2.083 in (52.9 mm)

Fuse Characteristics

Actuator Type:

Toggle Handle

Circuit Function:

Trip Free

No. of Poles:

3

Circuit Protection Type:

Operational Environment

Minimum Operating Temperature:

-35 °C (-31 °F)

Maximum Operating Temperature:

70 °C (158 °F)

Environmental Characteristics:

Corrosion Resistant; IP20

Design and Compliance

Reference Standard:

UL; TUV

Mounting and Packing

Terminal Shape:

Mounting Feature:

Manufacturer Highlights

E-t-a Elektrotechnische Apparate

In many industries, including machine construction, car production, process control and power engineering, E-T-A products are ideal for your application because of the wealth of product variations and configurations. We are able to meet the market demands with our comprehensive range of MCBs, conventional electro-mechanical circuit breakers, smart electronic overcurrent protection, switch mode power supplies and power distribution systems. E-T-A products make factory automation and systems engineering even more efficient. E-T-A is the world market leader for circuit breakers for equipment protection and circuit protectors. We offer you the world’s most comprehensive product portfolio in the areas of overcurrent protection, power distribution, circuit breakers for equipment protection, power- and solid state relays and intelligent, complete systems.

Category top products 20

Authentic purchasing experiences

Partstack™ will investigate all reported instances of potential suspect/counterfeit part listings.