CST1211-200LD by Coilcraft is a WOUND PRIMARY current sense transformer with 1:200 turns ratio. It has a peak primary current of 28A, inductance of 32000uH, and operates b/w -40 to 125°C. Ideal for AEC-Q200 approved applications requiring precise current sensing at frequencies up to 1000KHz.

Median Price

$3.900

Lifecycle Status

Suppliers In-Stock

2

In-Stock Inventory

1k+

Distributors (Authorized)

Supplier In-Stock 1+ parts 100+ parts 1k+ parts 10k+ parts

Coilcraft

USA . 726 parts In-Stock

1+ parts

$3.900

100+ parts

-

1k+ parts

$1.880

10k+ parts

$1.160

726

$3.900

-

$1.880

$1.160

Distributors (In-Stock)

Supplier In-Stock 1+ parts 100+ parts 1k+ parts 10k+ parts

Nova Conductors

Japan . 300 parts In-Stock

1+ parts

-

100+ parts

-

1k+ parts

-

10k+ parts

-

300

-

-

-

-

Distributors (Availability)

Supplier In-Stock 1+ parts 100+ parts 1k+ parts 10k+ parts

Argo Parts USA

USA . 1,706 parts In-Stock

1+ parts

-

100+ parts

-

1k+ parts

-

10k+ parts

-

1,706

-

-

-

-

Continental Prestige Electronics

USA . 1,519 parts In-Stock

1+ parts

-

100+ parts

-

1k+ parts

-

10k+ parts

-

1,519

-

-

-

-

Aranea Global

USA . 50 parts In-Stock

1+ parts

-

100+ parts

-

1k+ parts

-

10k+ parts

-

50

-

-

-

-

Overview

Experience the unparalleled quality and reliability of the CST1211-200LD by Coilcraft, a leading manufacturer of current sense transformers. Perfect for a wide range of applications, this transformer offers exceptional performance and efficiency. With its AEC-Q200 approval, you can trust in its durability and precision. Say goodbye to subpar products and discover the value and benefits that this transformer brings to your projects. Upgrade to Coilcraft and experience the difference today.

Feature Benefit Bullets

Type (Primary): WOUND PRIMARY

Wound primary type ensures reliable performance and accurate current sensing.

Approvals (V): AEC-Q200

AEC-Q200 approval indicates high quality and automotive grade reliability.

Packing Method: TR, EMBOSSED PLASTIC, 13 INCH

Embossed plastic packaging in 13-inch size provides protection and ease of handling during transportation and installation.

Minimum ET Product: 424 V-us

High minimum ET product ensures efficient energy transfer and performance.

Primary Current (Peak): 28 A

High peak primary current capacity allows for handling of high current flows effectively.

Maximum Operating Temperature: 125 °C

Wide operating temperature range makes this transformer suitable for various environments and applications.

Inductance (Secondary): 32000 uH

High secondary inductance ensures accurate current measurement and stability.

Minimum Operating Temperature: -40 °C

Low minimum operating temperature allows for reliable performance in cold environments.

Height: 11 mm

Compact height enables easy integration into space-constrained designs.

Width: 10.6 mm

Narrow width makes it suitable for applications where space is limited.

Load Resistance: 7.1 ohm

Optimal load resistance for accurate current sensing and minimal power loss.

Minimum Operating Frequency: 11 KHz

Low minimum operating frequency allows for precise current measurement at low frequencies.

Transformer Type: CURRENT SENSE TRANSFORMER

Specifically designed for current sensing applications, ensuring accurate and reliable performance.

Mounting Feature: SURFACE MOUNT

Surface mount capability facilitates easy and secure installation on PCBs.

Length: 12.2 mm

Optimal length for accommodating the necessary winding and providing good electrical isolation.

Turns Ratio (Np:Ns): 1:200

High turns ratio allows for precise current measurement and high sensitivity.

Maximum Operating Frequency: 1000 KHz

High maximum operating frequency enables accurate current sensing at high frequencies.

Technical Specifications

Current Sense Transformers CST1211-200LD attributes and parameters. Explore more Current Sense Transformers devices from Coilcraft

Specs

Additional Features:

LENGTH & HEIGHT DIM INCLUDE TERMINAL ALSO

Approvals (V):

Minimum ET Product:

424 V-us

Height:

11 mm

Length:

12.2 mm

Load Resistance:

7.1 ohm

Mounting Feature:

Maximum Operating Frequency:

1000 KHz

Minimum Operating Frequency:

11 KHz

Maximum Operating Temperature:

125 Cel

Minimum Operating Temperature:

-40 Cel

Packing Method:

TR, EMBOSSED PLASTIC, 13 INCH

Primary Current (Peak):

28 A

Type (Primary):

WOUND PRIMARY

Inductance (Secondary):

32000 uH

Transformer Type:

Turns Ratio (Np:Ns):

1:200

Width:

10.6 mm

Trade Compliance

CST1211-200LD Transformers trade compliance attributes, and parameters.

ECCN

EAR99

ECCN Governance

EAR

Manufacturer Highlights

Coilcraft

Headquartered in Cary, IL, Coilcraft has been a leader in the design, manufacture and distribution of high-performance magnetic components including RF chip inductors, power magnetics and filters since 1945. In addition to the industry’s largest selection of standard, off-the-shelf components, we also design and build custom magnetics to meet your precise requirements

Category top products 20

Authentic purchasing experiences

Partstack™ will investigate all reported instances of potential suspect/counterfeit part listings.

Similar products 6