Loading...

Tamura Power & Mains Transformers 5

Power & Mains Transformers
Part# Info Specs
Part RoHS Manufacturer Description Additional Features Application Approvals (V) Center Tap Feature-1 Center Tap Feature-2 Diameter Minimum ET Product Height Maximum Input Voltage (V) Minimum Input Voltage (V) Nominal Input Voltage (V) Isolation Voltage JESD-609 Code Length Load Resistance Manufacturer Series Mounting Feature No. of Functions No. of Winding (Primary) No. of Winding (Secondary) Maximum Operating Frequency Minimum Operating Frequency Nominal Operating Frequency Maximum Operating Temperature Minimum Operating Temperature Output Current-1 Output Current-2 Output Voltage-1 Output Voltage-2 Packing Method Dimensions Power Rating Inductance (Primary) Rating (Primary) Sub-Category Terminal Finish Transformer Type Turns Ratio (Np:Ns) Volt-Ampere Rating (VA) Width
3FS-224 by Tamura

3FS-224

Tamura

The Tamura 3FS-224 is a power transformer with UL and CSA approvals. It has two secondary windings, an output current of 0.045 A, and a VA rating of 1.1 VA. Ideal for applications requiring a nominal operating frequency of 60 HZ.

PCB MOUNTABLE

UL; CSA

2

60 HZ

.045 A

POWER TRANSFORMER

1.1 VA

3FD-248 by Tamura

3FD-248

Tamura

The Tamura 3FD-248 power transformer has a VA rating of 1.1VA, output current of 0.023A, and operates at 60Hz frequency. It is UL and CSA approved for various applications requiring reliable power supply solutions.

PCB MOUNTABLE

UL; CSA

2

60 HZ

.023 A

POWER TRANSFORMER

1.1 VA

3FD-512 by Tamura

3FD-512

Tamura

The Tamura 3FD-512 power transformer has a VA rating of 12VA, output current of 1A, and dual secondary windings. It is UL and CSA approved for applications requiring a 60Hz frequency. Ideal for various power supply applications due to its compact design and reliable performance.

PCB MOUNTABLE

UL; CSA

2

60 HZ

1 A

POWER TRANSFORMER

12 VA

10A009 by Tamura

10A009

Tamura

POWER TRANSFORMER; Approvals (V): UL; CSA; No. of Winding (Secondary): 1; Volt-Ampere Rating (VA): .7 VA; Additional Features: PCB MOUNTABLE; Nominal Operating Frequency: 60 HZ;

PCB MOUNTABLE

UL; CSA

1

60 HZ

.05 A

POWER TRANSFORMER

.7 VA

PLT56-32-130B by Tamura

PLT56-32-130B

Tamura

Tamura PLT56-32-130B is a 56 VA power transformer with dual 115V primary rating. It features output voltages of 27.5V and 9.3V, along with approvals from CSA, TUV, and UL. Ideal for applications requiring a center tap feature and through-hole mounting, suitable for various power supply needs at 50/60 HZ frequency.

CSA, TUV, UL

YES

NO

48.5 mm

115/230

76.2 mm

THROUGH HOLE MOUNTED

2

50/60 HZ

4 A

.68 A

27.5 V

9.3 V

DUAL 115V

POWER TRANSFORMER

56 VA

64 mm