Loading...

UL Power & Mains Transformers 8

Power & Mains Transformers
Part# Info Specs
Part RoHS Manufacturer Description Additional Features Application Approvals (V) Center Tap Feature-1 Center Tap Feature-2 Diameter Minimum ET Product Height Maximum Input Voltage (V) Minimum Input Voltage (V) Nominal Input Voltage (V) Isolation Voltage JESD-609 Code Length Load Resistance Manufacturer Series Mounting Feature No. of Functions No. of Winding (Primary) No. of Winding (Secondary) Maximum Operating Frequency Minimum Operating Frequency Nominal Operating Frequency Maximum Operating Temperature Minimum Operating Temperature Output Current-1 Output Current-2 Output Voltage-1 Output Voltage-2 Packing Method Dimensions Power Rating Inductance (Primary) Rating (Primary) Sub-Category Terminal Finish Transformer Type Turns Ratio (Np:Ns) Volt-Ampere Rating (VA) Width
45059 by Myrra Sas

45059

Myrra Sas

The Myrra Sas 45059 power transformer has dual 115V primary rating, 24 VA volt-ampere rating, and 4000 V isolation voltage. It is ideal for applications requiring a max operating temperature of 50°C, with output currents of 0.667 A and output voltages of 18 V.

PARALLEL CONNECTED

UL

NO

NO

31 mm

115

4000 V

68 mm

THROUGH HOLE MOUNTED

2

50 Cel

.667 A

.667 A

18 V

18 V

DUAL 115V

POWER TRANSFORMER

24 VA

57 mm

45063 by Myrra Sas

45063

Myrra Sas

The Myrra Sas 45063 power transformer has dual 115V primary rating, 30 VA volt-ampere rating, and UL approval. With isolation voltage of 4000 V, it outputs two secondary windings at 12V each with a max operating temperature of 50°C. Ideal for applications requiring reliable power conversion in compact spaces.

PARALLEL CONNECTED

UL

NO

NO

35 mm

115

4000 V

68 mm

THROUGH HOLE MOUNTED

2

50 Cel

1.25 A

1.25 A

12 V

12 V

DUAL 115V

POWER TRANSFORMER

30 VA

57 mm

45039 by Myrra Sas

45039

Myrra Sas

The Myrra Sas 45039 power transformer has dual 115V primary rating, 10 VA Volt-Ampere, and UL approval. With isolation voltage of 4000 V, it outputs two secondary windings at 12V each with a max operating temperature of 50°C. Ideal for applications requiring reliable power conversion in compact spaces.

PARALLEL CONNECTED

UL

NO

NO

22 mm

115

4000 V

68 mm

THROUGH HOLE MOUNTED

2

50 Cel

.416 A

.416 A

12 V

12 V

DUAL 115V

POWER TRANSFORMER

10 VA

57 mm

45052 by Myrra Sas

45052

Myrra Sas

45052 by Myrra Sas is a UL approved power transformer with dual 115V primary rating. It offers 18 VA volt-ampere rating, isolation voltage of 4000 V, and output currents of 0.6 A each. With through-hole mounting feature, it is ideal for applications requiring a max operating temperature of 50°C.

PARALLEL CONNECTED

UL

NO

NO

27 mm

115

4000 V

68 mm

THROUGH HOLE MOUNTED

2

50 Cel

.6 A

.6 A

15 V

15 V

DUAL 115V

POWER TRANSFORMER

18 VA

57 mm

45062 by Myrra Sas

45062

Myrra Sas

The Myrra Sas 45062 power transformer has dual 115V primary rating, 30 VA volt-ampere rating, and 4000 V isolation voltage. It is ideal for applications requiring a max operating temperature of 50°C, with two secondary windings each providing 1.667 A output current at 9 V.

PARALLEL CONNECTED

UL

NO

NO

35 mm

115

4000 V

68 mm

THROUGH HOLE MOUNTED

2

50 Cel

1.667 A

1.667 A

9 V

9 V

DUAL 115V

POWER TRANSFORMER

30 VA

57 mm

45042 by Myrra Sas

45042

Myrra Sas

45042 by Myrra Sas is a UL-approved power transformer with dual 115V primary rating. It offers two secondary windings, each with an output current of 0.208 A and voltage of 24 V. With an isolation voltage of 4000 V and a VA rating of 10 VA, this transformer is ideal for applications requiring reliable power conversion in compact spaces.

PARALLEL CONNECTED

UL

NO

NO

22 mm

115

4000 V

68 mm

THROUGH HOLE MOUNTED

2

50 Cel

.208 A

.208 A

24 V

24 V

DUAL 115V

POWER TRANSFORMER

10 VA

57 mm

45045 by Myrra Sas

45045

Myrra Sas

45045 by Myrra Sas is a UL-approved power transformer with dual 115V primary rating. It has two windings, each with an output current of 0.583 A and voltage of 12 V. With an isolation voltage of 4000 V and VA rating of 14 VA, it is ideal for applications requiring reliable power conversion in compact spaces.

PARALLEL CONNECTED

UL

NO

NO

24 mm

115

4000 V

68 mm

THROUGH HOLE MOUNTED

2

50 Cel

.583 A

.583 A

12 V

12 V

DUAL 115V

POWER TRANSFORMER

14 VA

57 mm

45064 by Myrra Sas

45064

Myrra Sas

45064 by Myrra Sas is a UL approved power transformer with dual 115V primary rating and 30 VA volt-ampere. It offers two secondary windings, each providing 1A output current at 15V voltage. With isolation voltage of 4000V and through-hole mounting feature, it is ideal for various power applications requiring up to 50°C operating temperature.

PARALLEL CONNECTED

UL

NO

NO

35 mm

115

4000 V

68 mm

THROUGH HOLE MOUNTED

2

50 Cel

1 A

1 A

15 V

15 V

DUAL 115V

POWER TRANSFORMER

30 VA

57 mm