Loading...

Electrical Wires & Cables

Electrical wires and cables are conductive materials that are used to transmit electrical power and signals from one location to another. They are an essential component of any electrical system, ranging from small electronic devices to large industrial installations.

Electrical wires are typically made of a conductive material, such as copper or aluminum, that is coated in an insulating material to prevent electrical leakage or short-circuits. They are available in various gauges and thicknesses to handle different levels of electrical current and resistance.

Cables, on the other hand, are bundles of two or more electrical wires that are wrapped in an outer jacket for protection and insulation. They are designed for specific purposes, such as transmitting high-speed data, audio, or video signals, and can be shielded or unshielded to reduce electromagnetic interference.

Both electrical wires and cables are critical components of modern electrical systems and are used in a wide range of applications, including residential and commercial buildings, automotive and aerospace industries, telecommunications, and more.

Electrical Wires & Cables

Available Parts 2,400+

Part# Info Specs
Part RoHS Manufacturer Description Additional Features Application Approvals (V) Cable Types Conductor Finish Conductor Material Connector Side-1 Connector Side-2 Connector Accessory Type Construction Cross Section Area DIN Conformity Design Diameter Finish Thickness IEC Conformity Insulator Material Jacket Material Length MIL Conformity Material Mounting Option-1 Mounting Option-2 Mounting Style No. of Conductors Maximum Operating Temperature Minimum Operating Temperature Rated Current Rated Voltage Rated DC Voltage Resistance Shielding Stranding Terminal Type Wire Gauge (AWG) Maximum Wire Size Minimum Wire Size Wire & Cable Name
1500936 by Phoenix Contact

1500936

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: YES;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.65 mm

NO

PP

PUR

.6 mm

NO

3

80 Cel

-40 Cel

4 A

60 V

.058 ohm

YES

42X0.10

22

COMMUNICATION CABLE

1500949 by Phoenix Contact

1500949

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: YES;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.65 mm

NO

PP

PUR

1.5 mm

NO

3

80 Cel

-40 Cel

4 A

60 V

.058 ohm

YES

42X0.10

22

COMMUNICATION CABLE

1500952 by Phoenix Contact

1500952

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: YES;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.65 mm

NO

PP

PUR

3 mm

NO

3

80 Cel

-40 Cel

4 A

60 V

.058 ohm

YES

42X0.10

22

COMMUNICATION CABLE

1500981 by Phoenix Contact

1500981

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: YES;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.95 mm

NO

PP

PUR

1.5 mm

NO

4

80 Cel

-40 Cel

4 A

60 V

.058 ohm

YES

42X0.10

22

COMMUNICATION CABLE

1501977 by Phoenix Contact

1501977

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

IP65, IP67, IP68

CUL; EAC; UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

3.85 mm

NO

POLYPROPYLENE

PUR

15 mm

NO

3

90 Cel

-25 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1504592 by Phoenix Contact

1504592

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

IP65, IP67, IP68

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.2 mm

NO

POLYPROPYLENE

PUR

2.5 mm

NO

4

90 Cel

-25 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1504615 by Phoenix Contact

1504615

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

IP65, IP67, IP68

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.2 mm

NO

POLYPROPYLENE

PUR

4 mm

NO

4

90 Cel

-25 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1507874 by Phoenix Contact

1507874

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

PLUG ANGLED

SOCKET STRAIGHT

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

4

4 A

60 V

NO

COMMUNICATION CABLE

1508734 by Phoenix Contact

1508734

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

PLUG ANGLED

SOCKET STRAIGHT

CABLE ASSEMBLY

.75 mm2

NO

NO

PUR/PVC

NO

5

105 Cel

4 A

60 V

NO

18

COMMUNICATION CABLE

1511718 by Phoenix Contact

1511718

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

4

4 A

60 V

NO

COMMUNICATION CABLE

1511802 by Phoenix Contact

1511802

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 24 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

3

105 Cel

4 A

24 V

NO

COMMUNICATION CABLE

1513318 by Phoenix Contact

1513318

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET ANGLED; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

PLUG ANGLED

SOCKET ANGLED

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

3

105 Cel

4 A

250 V

NO

COMMUNICATION CABLE

1513428 by Phoenix Contact

1513428

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

PLUG ANGLED

SOCKET STRAIGHT

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

3

105 Cel

4 A

250 V

NO

COMMUNICATION CABLE

1514197 by Phoenix Contact

1514197

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 24 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

3

4 A

24 V

NO

COMMUNICATION CABLE

1515031 by Phoenix Contact

1515031

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 24 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

4

4 A

24 V

NO

COMMUNICATION CABLE

1518119 by Phoenix Contact

1518119

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: YES;

CUL; EAC; UL

TIN

COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

7.8 mm

NO

FOAM PP

PUR

.5 mm

NO

2

80 Cel

-40 Cel

4 A

60 V

.079 ohm

YES

19X0.13

24

COMMUNICATION CABLE

1518122 by Phoenix Contact

1518122

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: YES;

CUL; EAC; UL

TIN

COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

7.8 mm

NO

FOAM PP

PUR

1 mm

NO

2

80 Cel

-40 Cel

4 A

60 V

.079 ohm

YES

19X0.13

24

COMMUNICATION CABLE

1518135 by Phoenix Contact

1518135

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: YES;

CUL; EAC; UL

TIN

COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

7.8 mm

NO

FOAM PP

PUR

2 mm

NO

2

80 Cel

-40 Cel

4 A

60 V

.079 ohm

YES

19X0.13

24

COMMUNICATION CABLE

1518164 by Phoenix Contact

1518164

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: YES;

CUL; EAC; UL

TIN

COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

7.8 mm

NO

FOAM PP

PUR

15 mm

NO

2

80 Cel

-40 Cel

4 A

60 V

.079 ohm

YES

19X0.13

24

COMMUNICATION CABLE

1518410 by Phoenix Contact

1518410

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.75 mm2

NO

6.3 mm

NO

PVC

PUR

.5 mm

NO

5

80 Cel

-25 Cel

4 A

60 V

.026 ohm

NO

42X0.15

18

COMMUNICATION CABLE

1518452 by Phoenix Contact

1518452

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.75 mm2

NO

6.3 mm

NO

PVC

PUR

10 mm

NO

5

80 Cel

-25 Cel

4 A

60 V

.026 ohm

NO

42X0.15

18

COMMUNICATION CABLE

1518724 by Phoenix Contact

1518724

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.4 mm

NO

POLYPROPYLENE

PUR

.3 mm

NO

3

90 Cel

-25 Cel

4 A

300 V

58 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518737 by Phoenix Contact

1518737

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.4 mm

NO

POLYPROPYLENE

PUR

.6 mm

NO

3

90 Cel

-25 Cel

4 A

300 V

58 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518740 by Phoenix Contact

1518740

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.4 mm

NO

POLYPROPYLENE

PUR

1.5 mm

NO

3

90 Cel

-25 Cel

4 A

300 V

58 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518753 by Phoenix Contact

1518753

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.4 mm

NO

POLYPROPYLENE

PUR

3 mm

NO

3

90 Cel

-25 Cel

4 A

300 V

58 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518766 by Phoenix Contact

1518766

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

UL

BARE COPPER LITZ

PLUG ANGLED

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

3.85 mm

NO

PP

PUR

.3 mm

NO

3

80 Cel

-40 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518779 by Phoenix Contact

1518779

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

UL

BARE COPPER LITZ

PLUG ANGLED

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

3.85 mm

NO

PP

PUR

.6 mm

NO

3

80 Cel

-40 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518889 by Phoenix Contact

1518889

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.7 mm

NO

POLYPROPYLENE

PUR

.3 mm

NO

4

90 Cel

-25 Cel

4 A

300 V

58 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518892 by Phoenix Contact

1518892

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.7 mm

NO

POLYPROPYLENE

PUR

.6 mm

NO

4

90 Cel

-25 Cel

4 A

300 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518902 by Phoenix Contact

1518902

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.2 mm

NO

PP

PUR

1.5 mm

NO

4

80 Cel

-40 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518915 by Phoenix Contact

1518915

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.7 mm

NO

POLYPROPYLENE

PUR

3 mm

NO

4

90 Cel

-25 Cel

4 A

300 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518928 by Phoenix Contact

1518928

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.7 mm

NO

POLYPROPYLENE

PUR

.3 mm

NO

4

90 Cel

-25 Cel

4 A

300 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518931 by Phoenix Contact

1518931

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.7 mm

NO

POLYPROPYLENE

PUR

.6 mm

NO

4

90 Cel

-25 Cel

4 A

300 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518944 by Phoenix Contact

1518944

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.7 mm

NO

POLYPROPYLENE

PUR

1.5 mm

NO

4

90 Cel

-25 Cel

4 A

300 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518957 by Phoenix Contact

1518957

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.7 mm

NO

POLYPROPYLENE

PUR

3 mm

NO

4

90 Cel

-25 Cel

4 A

300 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1519040 by Phoenix Contact

1519040

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

5 mm

NO

PUR

.3 mm

NO

5

90 Cel

-25 Cel

4 A

60 V

NO

42X0.10

22

COMMUNICATION CABLE

1519053 by Phoenix Contact

1519053

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

5 mm

NO

PUR

.6 mm

NO

5

90 Cel

-25 Cel

4 A

60 V

NO

42X0.10

22

COMMUNICATION CABLE

1519066 by Phoenix Contact

1519066

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

5 mm

NO

PUR

1.5 mm

NO

5

90 Cel

-25 Cel

4 A

60 V

NO

42X0.10

22

COMMUNICATION CABLE

1519079 by Phoenix Contact

1519079

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

5 mm

NO

PUR

3 mm

NO

5

90 Cel

-25 Cel

4 A

60 V

NO

42X0.10

22

COMMUNICATION CABLE

1519082 by Phoenix Contact

1519082

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

5 mm

NO

PUR

.3 mm

NO

5

90 Cel

-25 Cel

4 A

60 V

NO

42X0.10

22

COMMUNICATION CABLE

1519105 by Phoenix Contact

1519105

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

UL

BARE COPPER LITZ

PLUG ANGLED

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.55 mm

NO

PP

PUR

1.5 mm

NO

5

80 Cel

-40 Cel

4 A

60 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1519118 by Phoenix Contact

1519118

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

5 mm

NO

PUR

3 mm

NO

5

90 Cel

-25 Cel

4 A

60 V

NO

42X0.10

22

COMMUNICATION CABLE

1522671 by Phoenix Contact

1522671

Phoenix Contact

Phoenix Contact 1522671 is a stranded communication cable with PUR jacket, PP insulator, and bare copper litz conductor. It has approvals from CUL, EAC, and UL for 30V rated voltage. Ideal for applications requiring a temperature range of -40 to 80 °C, with 8 conductors and a cross-section area of 0.25 mm2.

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.3 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522684 by Phoenix Contact

1522684

Phoenix Contact

Phoenix Contact 1522684 is a stranded communication cable with PUR jacket, PP insulator, and bare copper litz conductor. It has approvals from CUL, EAC, and UL for 30V rated voltage. Ideal for applications requiring a temperature range of -40 to 80 °C, with 8 conductors and a cross-section area of 0.25 mm2.

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.6 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522697 by Phoenix Contact

1522697

Phoenix Contact

Phoenix Contact 1522697 is a stranded communication cable with PUR jacket, rated for 30V. Featuring 8 conductors of bare copper litz, it has a cross section area of 0.25mm2 and can handle up to 2A current. Ideal for applications requiring reliable data transmission in industrial settings.

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

1.5 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522707 by Phoenix Contact

1522707

Phoenix Contact

Phoenix Contact 1522707 is a stranded communication cable with PUR jacket, PP insulator, and bare copper litz conductor. It has approvals from CUL, EAC, and UL for 30V rated voltage. With a temperature range of -40 to 80 °C, it's ideal for applications requiring a 0.25 mm2 cross-section area and 2A rated current.

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

3 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522710 by Phoenix Contact

1522710

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

8

2 A

30 V

NO

COMMUNICATION CABLE

1522723 by Phoenix Contact

1522723

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.3 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE