Phoenix Contact Electrical Wires & Cables 696

Electrical Wires & Cables
Part# Info Specs
Part RoHS Manufacturer Description Additional Features Application Approvals (V) Cable Types Conductor Finish Conductor Material Connector Side-1 Connector Side-2 Connector Accessory Type Construction Cross Section Area DIN Conformity Design Diameter Finish Thickness IEC Conformity Insulator Material Jacket Material Length MIL Conformity Material Mounting Option-1 Mounting Option-2 Mounting Style No. of Conductors Maximum Operating Temperature Minimum Operating Temperature Rated Current Rated Voltage Rated DC Voltage Resistance Shielding Stranding Wire Gauge (AWG) Maximum Wire Size Minimum Wire Size Wire & Cable Name
1693351 by Phoenix Contact

1693351

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 24 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

3.6 mm

NO

PP

PUR

.3 mm

NO

3

80 Cel

-40 Cel

4 A

24 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1693364 by Phoenix Contact

1693364

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 24 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

3.6 mm

NO

PP

PUR

.6 mm

NO

3

80 Cel

-40 Cel

4 A

24 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1693380 by Phoenix Contact

1693380

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 24 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

3.6 mm

NO

PP

PUR

1.5 mm

NO

3

80 Cel

-40 Cel

4 A

24 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1693403 by Phoenix Contact

1693403

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 24 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

3.6 mm

NO

PP

PUR

3 mm

NO

3

80 Cel

-40 Cel

4 A

24 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1694884 by Phoenix Contact

1694884

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M8 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; IEC 61076-2-101; IEC 61076-2-104; UL

BARE COPPER LITZ

M12 PLUG

M8 SOCKET

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

3.6 mm

YES

PP

PUR

.3 mm

NO

3

80 Cel

-40 Cel

4 A

300 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1694897 by Phoenix Contact

1694897

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 24 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

3.6 mm

NO

PP

PUR

.6 mm

NO

3

80 Cel

-40 Cel

4 A

24 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1694907 by Phoenix Contact

1694907

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 24 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

3.6 mm

NO

PP

PUR

1.5 mm

NO

3

80 Cel

-40 Cel

4 A

24 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1694910 by Phoenix Contact

1694910

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 24 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

3.6 mm

NO

PP

PUR

3 mm

NO

3

80 Cel

-40 Cel

4 A

24 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

2761295 by Phoenix Contact

2761295

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB-9 FEMALE; Connector Side-2: D-SUB-25 MALE; Shielding: NO; IEC Conformity: NO; DIN Conformity: NO;

EAC

D-SUB-9 FEMALE

D-SUB-25 MALE

CABLE ASSEMBLY

NO

NO

.15 mm

NO

9

NO

COMMUNICATION CABLE

2799474 by Phoenix Contact

2799474

Phoenix Contact

Phoenix Contact 2799474 is a 2mm COMMUNICATION CABLE with D-SUB-9 FEMALE connectors on both sides. It has 9 conductors and EAC approval, making it ideal for electrical applications requiring reliable data transmission over short distances.

EAC

D-SUB-9 FEMALE

D-SUB-9 FEMALE

CABLE ASSEMBLY

NO

NO

2 mm

NO

9

NO

COMMUNICATION CABLE

1668713 by Phoenix Contact

1668713

Phoenix Contact

Phoenix Contact 1668713 is a stranded communication cable with PUR jacket, PP insulator, and bare copper litz conductor. It has approvals from CUL, EAC, IEC 61076-2-101, and UL for use in applications requiring a rated voltage of 300V. With a cross-section area of 0.34 mm2 and rated current of 4A, it is ideal for M12 plug to socket connections in various electrical installations.

CUL; EAC; IEC 61076-2-101; UL

BARE COPPER LITZ

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.2 mm

YES

PP

PUR

.3 mm

NO

4

80 Cel

-40 Cel

4 A

300 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1668593 by Phoenix Contact

1668593

Phoenix Contact

Phoenix Contact 1668593 is a stranded communication cable with PUR jacket, PP insulator, and bare copper litz conductor. It has approvals from CUL, EAC, and UL for 250V rated voltage. With a max operating temperature of 80°C and min of -40°C, it's ideal for electrical applications requiring flexibility and durability.

CUL; EAC; UL

BARE COPPER LITZ

PLUG ANGLED

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.2 mm

NO

PP

PUR

.3 mm

NO

4

80 Cel

-40 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1668726 by Phoenix Contact

1668726

Phoenix Contact

The Phoenix Contact 1668726 is a stranded electrical wire with a PUR jacket material and PP insulator. It has a rated voltage of 250V, max operating temperature of 80°C, and min operating temperature of -40°C. This communication cable has 4 conductors, a cross section area of 0.34mm2, and is suitable for applications requiring a plug angled connector on one side and socket angled connector on the other.

CUL; EAC; UL

BARE COPPER LITZ

PLUG ANGLED

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.2 mm

NO

PP

PUR

.6 mm

NO

4

80 Cel

-40 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1668603 by Phoenix Contact

1668603

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG ANGLED

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.2 mm

NO

PP

PUR

.6 mm

NO

4

80 Cel

-40 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1668739 by Phoenix Contact

1668739

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET ANGLED; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG ANGLED

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.2 mm

NO

PP

PUR

1.5 mm

NO

4

80 Cel

-40 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1668742 by Phoenix Contact

1668742

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET ANGLED; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG ANGLED

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.2 mm

NO

PP

PUR

3 mm

NO

4

80 Cel

-40 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1668470 by Phoenix Contact

1668470

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.2 mm

NO

PP

PUR

.3 mm

NO

4

80 Cel

-40 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1668357 by Phoenix Contact

1668357

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.2 mm

NO

PP

PUR

.3 mm

NO

4

80 Cel

-40 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1668483 by Phoenix Contact

1668483

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.2 mm

NO

PP

PUR

.6 mm

NO

4

80 Cel

-40 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1668360 by Phoenix Contact

1668360

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.2 mm

NO

PP

PUR

.6 mm

NO

4

80 Cel

-40 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1668496 by Phoenix Contact

1668496

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.2 mm

NO

PP

PUR

1.5 mm

NO

4

80 Cel

-40 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1668373 by Phoenix Contact

1668373

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.2 mm

NO

PP

PUR

1.5 mm

NO

4

80 Cel

-40 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1668506 by Phoenix Contact

1668506

Phoenix Contact

Phoenix Contact 1668506 is a stranded communication cable with PUR jacket, PP insulator, and bare copper litz conductor. It has approvals from CUL, EAC, and UL for 250V rated voltage. Ideal for applications requiring a temperature range of -40 to 80 °C with 4A rated current.

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.2 mm

NO

PP

PUR

3 mm

NO

4

80 Cel

-40 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

2867403 by Phoenix Contact

2867403

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: SMA (MALE); Connector Side-2: N (MALE); Shielding: YES; No. of Conductors: 1; Minimum Operating Temperature: -40 Cel;

SMA (MALE)

N (MALE)

CABLE ASSEMBLY

STRANDED

NO

2.5 mm

NO

FLUORINATED ETHYLENE PROPYLENE

1.2 mm

NO

1

75 Cel

-40 Cel

YES

COMMUNICATION CABLE

2885207 by Phoenix Contact

2885207

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: MCX (MALE); Connector Side-2: N (MALE); Shielding: YES; Diameter: 2.5 mm; No. of Conductors: 1;

MCX (MALE)

N (MALE)

CABLE ASSEMBLY

STRANDED

NO

2.5 mm

NO

FLUORINATED ETHYLENE PROPYLENE

1.2 mm

NO

1

75 Cel

-40 Cel

YES

COMMUNICATION CABLE

2318318 by Phoenix Contact

2318318

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.1 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1 mm

NO

10

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2318392 by Phoenix Contact

2318392

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2318402 by Phoenix Contact

2318402

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1.5 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2318457 by Phoenix Contact

2318457

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2318635 by Phoenix Contact

2318635

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

8.3 mm

NO

POLYVINYL CHLORIDE

1 mm

NO

26

50 Cel

-20 Cel

1 A

60 V

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2318648 by Phoenix Contact

2318648

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

8.3 mm

NO

POLYVINYL CHLORIDE

1.5 mm

NO

26

50 Cel

-20 Cel

1 A

60 V

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2318664 by Phoenix Contact

2318664

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

8.3 mm

NO

POLYVINYL CHLORIDE

3 mm

NO

26

50 Cel

-20 Cel

1 A

60 V

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2318716 by Phoenix Contact

2318716

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

8.7 mm

NO

POLYVINYL CHLORIDE

1 mm

NO

34

50 Cel

-20 Cel

1 A

60 V

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2318774 by Phoenix Contact

2318774

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

8.7 mm

NO

POLYVINYL CHLORIDE

NO

34

50 Cel

-20 Cel

1 A

60 V

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2318790 by Phoenix Contact

2318790

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

POLYVINYL CHLORIDE

1 mm

NO

40

50 Cel

-20 Cel

1 A

60 V

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2318800 by Phoenix Contact

2318800

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

.14 mm2

NO

9.9 mm

NO

PVC

1.5 mm

NO

40

50 Cel

-20 Cel

1 A

60 V

NO

26

COMMUNICATION CABLE

2318813 by Phoenix Contact

2318813

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

.14 mm2

NO

9.9 mm

NO

PVC

2 mm

NO

40

50 Cel

-20 Cel

1 A

60 V

NO

26

COMMUNICATION CABLE

2318826 by Phoenix Contact

2318826

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

.14 mm2

NO

9.9 mm

NO

PVC

3 mm

NO

40

50 Cel

-20 Cel

1 A

60 V

NO

26

COMMUNICATION CABLE

2318842 by Phoenix Contact

2318842

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

.14 mm2

NO

9.9 mm

NO

PVC

6 mm

NO

40

50 Cel

-20 Cel

1 A

60 V

NO

26

COMMUNICATION CABLE

2318884 by Phoenix Contact

2318884

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

.14 mm2

NO

10.3 mm

NO

PVC

1.5 mm

NO

50

50 Cel

-20 Cel

1 A

60 V

NO

26

COMMUNICATION CABLE

2318907 by Phoenix Contact

2318907

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

POLYVINYL CHLORIDE

3 mm

NO

50

50 Cel

-20 Cel

1 A

60 V

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2318936 by Phoenix Contact

2318936

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

POLYVINYL CHLORIDE

NO

50

50 Cel

-20 Cel

1 A

60 V

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2321745 by Phoenix Contact

2321745

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: FUJITSU CONN.; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

ASSEMBLY HAVE 4 CABLES

CUL; EAC; UL

TIN

COPPER

FUJITSU CONN.

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.1 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

3 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2321758 by Phoenix Contact

2321758

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: FUJITSU CONN.; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

ASSEMBLY HAVE 4 CABLES

CUL; EAC; UL

TIN

COPPER

FUJITSU CONN.

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.1 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

4 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2321761 by Phoenix Contact

2321761

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: FUJITSU CONN.; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

ASSEMBLY HAVE 4 CABLES

CUL; EAC; UL

TIN

COPPER

FUJITSU CONN.

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.1 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

6 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2321774 by Phoenix Contact

2321774

Phoenix Contact

Phoenix Contact 2321774 is a stranded wire with semi-rigid PVC jacket, rated for 60V and -40 to 70°C. Featuring tin finish copper conductor, it has 14 conductors at 0.14mm2 cross-section area. Ideal for flexible cord and fixture wire applications with FUJITSU CONN. to IDC/FLK SOCKET connectors.

ASSEMBLY HAVE 4 CABLES

CUL; EAC; UL

TIN

COPPER

FUJITSU CONN.

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.1 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

8 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2321787 by Phoenix Contact

2321787

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: FUJITSU CONN.; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

ASSEMBLY HAVE 4 CABLES

CUL; EAC; UL

TIN

COPPER

FUJITSU CONN.

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.1 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

10 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2736961 by Phoenix Contact

2736961

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 CONN.; Connector Side-2: 2 M8 MALE CONN.; Shielding: NO; Wire & Cable Name: COMMUNICATION CABLE; Minimum Operating Temperature: -25 Cel;

M12 CONN.

2 M8 MALE CONN.

CABLE ASSEMBLY

NO

NO

NO

5

60 Cel

-25 Cel

NO

COMMUNICATION CABLE