Loading...

Phoenix Contact Electrical Wires & Cables 696

Electrical Wires & Cables
Part# Info Specs
Part RoHS Manufacturer Description Additional Features Application Approvals (V) Cable Types Conductor Finish Conductor Material Connector Side-1 Connector Side-2 Connector Accessory Type Construction Cross Section Area DIN Conformity Design Diameter Finish Thickness IEC Conformity Insulator Material Jacket Material Length MIL Conformity Material Mounting Option-1 Mounting Option-2 Mounting Style No. of Conductors Maximum Operating Temperature Minimum Operating Temperature Rated Current Rated Voltage Rated DC Voltage Resistance Shielding Stranding Wire Gauge (AWG) Maximum Wire Size Minimum Wire Size Wire & Cable Name
1518779 by Phoenix Contact

1518779

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

UL

BARE COPPER LITZ

PLUG ANGLED

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

3.85 mm

NO

PP

PUR

.6 mm

NO

3

80 Cel

-40 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518889 by Phoenix Contact

1518889

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.7 mm

NO

POLYPROPYLENE

PUR

.3 mm

NO

4

90 Cel

-25 Cel

4 A

300 V

58 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518892 by Phoenix Contact

1518892

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.7 mm

NO

POLYPROPYLENE

PUR

.6 mm

NO

4

90 Cel

-25 Cel

4 A

300 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518902 by Phoenix Contact

1518902

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.2 mm

NO

PP

PUR

1.5 mm

NO

4

80 Cel

-40 Cel

4 A

250 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518915 by Phoenix Contact

1518915

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.7 mm

NO

POLYPROPYLENE

PUR

3 mm

NO

4

90 Cel

-25 Cel

4 A

300 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518928 by Phoenix Contact

1518928

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.7 mm

NO

POLYPROPYLENE

PUR

.3 mm

NO

4

90 Cel

-25 Cel

4 A

300 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518931 by Phoenix Contact

1518931

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.7 mm

NO

POLYPROPYLENE

PUR

.6 mm

NO

4

90 Cel

-25 Cel

4 A

300 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518944 by Phoenix Contact

1518944

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.7 mm

NO

POLYPROPYLENE

PUR

1.5 mm

NO

4

90 Cel

-25 Cel

4 A

300 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1518957 by Phoenix Contact

1518957

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 300 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.7 mm

NO

POLYPROPYLENE

PUR

3 mm

NO

4

90 Cel

-25 Cel

4 A

300 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1519040 by Phoenix Contact

1519040

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

5 mm

NO

PUR

.3 mm

NO

5

90 Cel

-25 Cel

4 A

60 V

NO

42X0.10

22

COMMUNICATION CABLE

1519053 by Phoenix Contact

1519053

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

5 mm

NO

PUR

.6 mm

NO

5

90 Cel

-25 Cel

4 A

60 V

NO

42X0.10

22

COMMUNICATION CABLE

1519066 by Phoenix Contact

1519066

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

5 mm

NO

PUR

1.5 mm

NO

5

90 Cel

-25 Cel

4 A

60 V

NO

42X0.10

22

COMMUNICATION CABLE

1519079 by Phoenix Contact

1519079

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

5 mm

NO

PUR

3 mm

NO

5

90 Cel

-25 Cel

4 A

60 V

NO

42X0.10

22

COMMUNICATION CABLE

1519082 by Phoenix Contact

1519082

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

5 mm

NO

PUR

.3 mm

NO

5

90 Cel

-25 Cel

4 A

60 V

NO

42X0.10

22

COMMUNICATION CABLE

1519105 by Phoenix Contact

1519105

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

UL

BARE COPPER LITZ

PLUG ANGLED

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

4.55 mm

NO

PP

PUR

1.5 mm

NO

5

80 Cel

-40 Cel

4 A

60 V

.058 ohm

NO

42X0.10

22

COMMUNICATION CABLE

1519118 by Phoenix Contact

1519118

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

BARE COPPER

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

STRANDED

.34 mm2

NO

5 mm

NO

PUR

3 mm

NO

5

90 Cel

-25 Cel

4 A

60 V

NO

42X0.10

22

COMMUNICATION CABLE

1522671 by Phoenix Contact

1522671

Phoenix Contact

Phoenix Contact 1522671 is a stranded communication cable with PUR jacket, PP insulator, and bare copper litz conductor. It has approvals from CUL, EAC, and UL for 30V rated voltage. Ideal for applications requiring a temperature range of -40 to 80 °C, with 8 conductors and a cross-section area of 0.25 mm2.

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.3 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522684 by Phoenix Contact

1522684

Phoenix Contact

Phoenix Contact 1522684 is a stranded communication cable with PUR jacket, PP insulator, and bare copper litz conductor. It has approvals from CUL, EAC, and UL for 30V rated voltage. Ideal for applications requiring a temperature range of -40 to 80 °C, with 8 conductors and a cross-section area of 0.25 mm2.

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.6 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522697 by Phoenix Contact

1522697

Phoenix Contact

Phoenix Contact 1522697 is a stranded communication cable with PUR jacket, rated for 30V. Featuring 8 conductors of bare copper litz, it has a cross section area of 0.25mm2 and can handle up to 2A current. Ideal for applications requiring reliable data transmission in industrial settings.

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

1.5 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522707 by Phoenix Contact

1522707

Phoenix Contact

Phoenix Contact 1522707 is a stranded communication cable with PUR jacket, PP insulator, and bare copper litz conductor. It has approvals from CUL, EAC, and UL for 30V rated voltage. With a temperature range of -40 to 80 °C, it's ideal for applications requiring a 0.25 mm2 cross-section area and 2A rated current.

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

3 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522710 by Phoenix Contact

1522710

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

8

2 A

30 V

NO

COMMUNICATION CABLE

1522723 by Phoenix Contact

1522723

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.3 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522736 by Phoenix Contact

1522736

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.6 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522749 by Phoenix Contact

1522749

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

1.5 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522752 by Phoenix Contact

1522752

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

3 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

NO

32X0.10

24

COMMUNICATION CABLE

1522765 by Phoenix Contact

1522765

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

8

2 A

30 V

NO

COMMUNICATION CABLE

1522969 by Phoenix Contact

1522969

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.3 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

YES

32X0.10

24

COMMUNICATION CABLE

1522972 by Phoenix Contact

1522972

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.6 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

YES

32X0.10

24

COMMUNICATION CABLE

1522985 by Phoenix Contact

1522985

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

1.5 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

YES

32X0.10

24

COMMUNICATION CABLE

1523007 by Phoenix Contact

1523007

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

CUL; EAC; UL

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

8

2 A

30 V

NO

COMMUNICATION CABLE

1523010 by Phoenix Contact

1523010

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.3 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

YES

32X0.10

24

COMMUNICATION CABLE

1523023 by Phoenix Contact

1523023

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

.6 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

YES

32X0.10

24

COMMUNICATION CABLE

1523036 by Phoenix Contact

1523036

Phoenix Contact

Phoenix Contact 1523036 is a stranded communication cable with PUR jacket, shielding, and PP insulator. It has 8 conductors of bare copper litz with 0.25 mm2 cross section area. Rated for 30V and 2A, it's ideal for applications requiring flexibility and durability in electrical wiring systems.

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

1.5 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

YES

32X0.10

24

COMMUNICATION CABLE

1523049 by Phoenix Contact

1523049

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: YES;

CUL; EAC; UL

BARE COPPER LITZ

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

STRANDED

.25 mm2

NO

5.9 mm

NO

PP

PUR

3 mm

NO

8

80 Cel

-40 Cel

2 A

30 V

.078 ohm

YES

32X0.10

24

COMMUNICATION CABLE

1523544 by Phoenix Contact

1523544

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

UL

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

3

105 Cel

4 A

250 V

NO

COMMUNICATION CABLE

1523557 by Phoenix Contact

1523557

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

UL

PLUG ANGLED

SOCKET STRAIGHT

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

3

105 Cel

4 A

250 V

NO

COMMUNICATION CABLE

1523586 by Phoenix Contact

1523586

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

NO

NO

NO

4

90 Cel

-25 Cel

4 A

250 V

NO

COMMUNICATION CABLE

1523599 by Phoenix Contact

1523599

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 250 V; Rated Current: 4 A; Shielding: NO;

UL

PLUG ANGLED

SOCKET STRAIGHT

CABLE ASSEMBLY

.75 mm2

NO

NO

PUR/PVC

NO

4

105 Cel

4 A

250 V

NO

18

COMMUNICATION CABLE

1523625 by Phoenix Contact

1523625

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

IP65, IP68, IP69K

UL

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

NO

NO

NO

5

90 Cel

-25 Cel

4 A

60 V

NO

COMMUNICATION CABLE

1523638 by Phoenix Contact

1523638

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG ANGLED; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

UL

PLUG ANGLED

SOCKET STRAIGHT

CABLE ASSEMBLY

.75 mm2

NO

NO

PUR/PVC

NO

5

105 Cel

4 A

60 V

NO

18

COMMUNICATION CABLE

1523683 by Phoenix Contact

1523683

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

IP65, IP68, IP69K

UL

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

NO

NO

NO

8

90 Cel

-25 Cel

2 A

30 V

NO

COMMUNICATION CABLE

1523696 by Phoenix Contact

1523696

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 30 V; Rated Current: 2 A; Shielding: NO;

UL

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

8

2 A

30 V

NO

COMMUNICATION CABLE

1523748 by Phoenix Contact

1523748

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

UL

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

3

4 A

60 V

NO

COMMUNICATION CABLE

1523751 by Phoenix Contact

1523751

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

UL

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

3

4 A

60 V

NO

COMMUNICATION CABLE

1523803 by Phoenix Contact

1523803

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET STRAIGHT; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

UL

PLUG STRAIGHT

SOCKET STRAIGHT

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

4

4 A

60 V

NO

COMMUNICATION CABLE

1523816 by Phoenix Contact

1523816

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

CUL; EAC; UL

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

4

4 A

60 V

NO

COMMUNICATION CABLE

1523861 by Phoenix Contact

1523861

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: M12 PLUG; Connector Side-2: M12 SOCKET; Shielding: NO; No. of Conductors: 5; Wire & Cable Name: COMMUNICATION CABLE;

M12 PLUG

M12 SOCKET

CABLE ASSEMBLY

NO

NO

NO

5

NO

COMMUNICATION CABLE

1523874 by Phoenix Contact

1523874

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: PLUG STRAIGHT; Connector Side-2: SOCKET ANGLED; Rated Voltage: 60 V; Rated Current: 4 A; Shielding: NO;

UL

PLUG STRAIGHT

SOCKET ANGLED

CABLE ASSEMBLY

NO

NO

PUR/PVC

NO

5

4 A

60 V

NO

COMMUNICATION CABLE