Loading...

IDC/FLK SOCKET Electrical Wires & Cables 225

Electrical Wires & Cables
Part# Info Specs
Part RoHS Manufacturer Description Additional Features Application Approvals (V) Cable Types Conductor Finish Conductor Material Connector Side-1 Connector Side-2 Connector Accessory Type Construction Cross Section Area DIN Conformity Design Diameter Finish Thickness IEC Conformity Insulator Material Jacket Material Length MIL Conformity Material Mounting Option-1 Mounting Option-2 Mounting Style No. of Conductors Maximum Operating Temperature Minimum Operating Temperature Rated Current Rated Voltage Rated DC Voltage Resistance Shielding Stranding Terminal Type Wire Gauge (AWG) Maximum Wire Size Minimum Wire Size Wire & Cable Name
2301134 by Phoenix Contact

2301134

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.8 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1 mm

NO

16

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2301545 by Phoenix Contact

2301545

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.8 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

2 mm

NO

16

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2302405 by Phoenix Contact

2302405

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

ASSEMBLY HAVE 4 CABLES

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2302492 by Phoenix Contact

2302492

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

ASSEMBLY HAVE 4 CABLES

CUL; EAC; UL

TIN

COPPER

D-SUB SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

2 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

COMMUNICATION CABLE

2302528 by Phoenix Contact

2302528

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

ASSEMBLY HAVE 4 CABLES

CUL; EAC; UL

TIN

COPPER

D-SUB SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

1 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

COMMUNICATION CABLE

2302544 by Phoenix Contact

2302544

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

ASSEMBLY HAVE 4 CABLES

CUL; EAC; UL

TIN

COPPER

D-SUB SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

3 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

COMMUNICATION CABLE

2302609 by Phoenix Contact

2302609

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

D-SUB SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1 mm

NO

48

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

COMMUNICATION CABLE

2302612 by Phoenix Contact

2302612

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

D-SUB SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

2 mm

NO

48

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

COMMUNICATION CABLE

2302667 by Phoenix Contact

2302667

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

D-SUB SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

2 mm

NO

40

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

COMMUNICATION CABLE

2302670 by Phoenix Contact

2302670

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

D-SUB SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

10.3 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

3 mm

NO

40

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

COMMUNICATION CABLE

2302706 by Phoenix Contact

2302706

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

ASSEMBLY HAVE 4 CABLES

CUL; EAC; UL

TIN

COPPER

D-SUB SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

COMMUNICATION CABLE

2302803 by Phoenix Contact

2302803

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: FUJITSU CONN.; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

FUJITSU CONN.

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

NO

36

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2302829 by Phoenix Contact

2302829

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: FUJITSU CONN.; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

FUJITSU CONN.

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

NO

40

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304157 by Phoenix Contact

2304157

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: FUJITSU CONN.; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

FUJITSU CONN.

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

2 mm

NO

40

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304160 by Phoenix Contact

2304160

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: FUJITSU CONN.; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

FUJITSU CONN.

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1 mm

NO

36

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304173 by Phoenix Contact

2304173

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: FUJITSU CONN.; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

FUJITSU CONN.

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

2 mm

NO

36

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304186 by Phoenix Contact

2304186

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: FUJITSU CONN.; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

ASSEMBLY HAVE 4 CABLES

CUL; EAC; UL

TIN

COPPER

FUJITSU CONN.

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.1 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304296 by Phoenix Contact

2304296

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.8 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

.5 mm

NO

16

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304319 by Phoenix Contact

2304319

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.8 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

.3 mm

NO

16

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304322 by Phoenix Contact

2304322

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.8 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

3 mm

NO

16

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304335 by Phoenix Contact

2304335

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

.14 mm2

NO

6.8 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

NO

16

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304348 by Phoenix Contact

2304348

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

.3 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304351 by Phoenix Contact

2304351

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

.5 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304364 by Phoenix Contact

2304364

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

3 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304377 by Phoenix Contact

2304377

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304403 by Phoenix Contact

2304403

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

3 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304416 by Phoenix Contact

2304416

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304542 by Phoenix Contact

2304542

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: YES;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

7 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1 mm

NO

16

70 Cel

-40 Cel

1 A

60 V

.145 ohm

YES

26

FLEXIBLE CORD AND FIXTURE WIRE

2304555 by Phoenix Contact

2304555

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: YES;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

7 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

2 mm

NO

16

70 Cel

-40 Cel

1 A

60 V

.145 ohm

YES

26

FLEXIBLE CORD AND FIXTURE WIRE

2304623 by Phoenix Contact

2304623

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: YES;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

7 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1.5 mm

NO

16

70 Cel

-40 Cel

1 A

60 V

.145 ohm

YES

26

FLEXIBLE CORD AND FIXTURE WIRE

2304678 by Phoenix Contact

2304678

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: D-SUB SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

ASSEMBLY HAVE 2 CABLES

CUL; EAC; UL

TIN

COPPER

D-SUB SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

5 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

COMMUNICATION CABLE

2304704 by Phoenix Contact

2304704

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

5.8 mm

NO

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304717 by Phoenix Contact

2304717

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

5.8 mm

NO

5 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304872 by Phoenix Contact

2304872

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

.5 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304898 by Phoenix Contact

2304898

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

1 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304940 by Phoenix Contact

2304940

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

8 mm

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2304966 by Phoenix Contact

2304966

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

.14 mm2

NO

9.9 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

NO

50

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2305059 by Phoenix Contact

2305059

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

.14 mm2

NO

7.6 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

.5 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2305185 by Phoenix Contact

2305185

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

4 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2305198 by Phoenix Contact

2305198

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

4 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2305402 by Phoenix Contact

2305402

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

ASSEMBLY HAVE 4 CABLES

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

6.4 mm

NO

SEMI-RIGID POLYVINYL CHLORIDE

2.5 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2305952 by Phoenix Contact

2305952

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

5.8 mm

NO

.5 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2305978 by Phoenix Contact

2305978

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

5.8 mm

NO

1.5 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2305981 by Phoenix Contact

2305981

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

5.8 mm

NO

2 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2305994 by Phoenix Contact

2305994

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

5.8 mm

NO

2.5 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2306003 by Phoenix Contact

2306003

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

5.8 mm

NO

6 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2314011 by Phoenix Contact

2314011

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

5.8 mm

NO

7 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE

2314024 by Phoenix Contact

2314024

Phoenix Contact

CABLE ASSEMBLY; Connector Side-1: IDC/FLK SOCKET; Connector Side-2: IDC/FLK SOCKET; Rated Voltage: 60 V; Rated Current: 1 A; Shielding: NO;

CUL; EAC; UL

TIN

COPPER

IDC/FLK SOCKET

IDC/FLK SOCKET

CABLE ASSEMBLY

STRANDED

.14 mm2

NO

5.8 mm

NO

8 mm

NO

14

70 Cel

-40 Cel

1 A

60 V

.145 ohm

NO

26

FLEXIBLE CORD AND FIXTURE WIRE